Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography
PURPOSE: To assess the interdevice agreement between swept-source Fourier-domain and time-domain anterior segment optical coherence tomography (AS-OCT). METHODS: Fifty-three eyes from 41 subjects underwent CASIA2 and Visante OCT imaging. One hundred eighty–degree axis images were measured with the b...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5863688/ https://www.ncbi.nlm.nih.gov/pubmed/29625479 http://dx.doi.org/10.1167/iovs.17-23574 |
_version_ | 1783308424626307072 |
---|---|
author | Chansangpetch, Sunee Nguyen, Anwell Mora, Marta Badr, Mai He, Mingguang Porco, Travis C. Lin, Shan C. |
author_facet | Chansangpetch, Sunee Nguyen, Anwell Mora, Marta Badr, Mai He, Mingguang Porco, Travis C. Lin, Shan C. |
author_sort | Chansangpetch, Sunee |
collection | PubMed |
description | PURPOSE: To assess the interdevice agreement between swept-source Fourier-domain and time-domain anterior segment optical coherence tomography (AS-OCT). METHODS: Fifty-three eyes from 41 subjects underwent CASIA2 and Visante OCT imaging. One hundred eighty–degree axis images were measured with the built-in two-dimensional analysis software for the swept-source Fourier-domain AS-OCT (CASIA2) and a customized program for the time-domain AS-OCT (Visante OCT). In both devices, we examined the angle opening distance (AOD), trabecular iris space area (TISA), angle recess area (ARA), anterior chamber depth (ACD), anterior chamber width (ACW), and lens vault (LV). Bland-Altman plots and intraclass correlation (ICC) were performed. Orthogonal linear regression assessed any proportional bias. RESULTS: ICC showed strong correlation for LV (0.925) and ACD (0.992) and moderate agreement for ACW (0.801). ICC suggested good agreement for all angle parameters (0.771–0.878) except temporal AOD500 (0.743) and ARA750 (nasal 0.481; temporal 0.481). There was a proportional bias in nasal ARA750 (slope 2.44, 95% confidence interval [CI]: 1.95–3.18), temporal ARA750 (slope 2.57, 95% CI: 2.04–3.40), and nasal TISA500 (slope 1.30, 95% CI: 1.12–1.54). Bland-Altman plots demonstrated in all measured parameters a minimal mean difference between the two devices (−0.089 to 0.063); however, evidence of constant bias was found in nasal AOD250, nasal AOD500, nasal AOD750, nasal ARA750, temporal AOD500, temporal AOD750, temporal ARA750, and ACD. Among the parameters with constant biases, CASIA2 tends to give the larger numbers. CONCLUSIONS: Both devices had generally good agreement. However, there were proportional and constant biases in most angle parameters. Thus, it is not recommended that values be used interchangeably. |
format | Online Article Text |
id | pubmed-5863688 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Association for Research in Vision and Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-58636882018-03-23 Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography Chansangpetch, Sunee Nguyen, Anwell Mora, Marta Badr, Mai He, Mingguang Porco, Travis C. Lin, Shan C. Invest Ophthalmol Vis Sci Glaucoma PURPOSE: To assess the interdevice agreement between swept-source Fourier-domain and time-domain anterior segment optical coherence tomography (AS-OCT). METHODS: Fifty-three eyes from 41 subjects underwent CASIA2 and Visante OCT imaging. One hundred eighty–degree axis images were measured with the built-in two-dimensional analysis software for the swept-source Fourier-domain AS-OCT (CASIA2) and a customized program for the time-domain AS-OCT (Visante OCT). In both devices, we examined the angle opening distance (AOD), trabecular iris space area (TISA), angle recess area (ARA), anterior chamber depth (ACD), anterior chamber width (ACW), and lens vault (LV). Bland-Altman plots and intraclass correlation (ICC) were performed. Orthogonal linear regression assessed any proportional bias. RESULTS: ICC showed strong correlation for LV (0.925) and ACD (0.992) and moderate agreement for ACW (0.801). ICC suggested good agreement for all angle parameters (0.771–0.878) except temporal AOD500 (0.743) and ARA750 (nasal 0.481; temporal 0.481). There was a proportional bias in nasal ARA750 (slope 2.44, 95% confidence interval [CI]: 1.95–3.18), temporal ARA750 (slope 2.57, 95% CI: 2.04–3.40), and nasal TISA500 (slope 1.30, 95% CI: 1.12–1.54). Bland-Altman plots demonstrated in all measured parameters a minimal mean difference between the two devices (−0.089 to 0.063); however, evidence of constant bias was found in nasal AOD250, nasal AOD500, nasal AOD750, nasal ARA750, temporal AOD500, temporal AOD750, temporal ARA750, and ACD. Among the parameters with constant biases, CASIA2 tends to give the larger numbers. CONCLUSIONS: Both devices had generally good agreement. However, there were proportional and constant biases in most angle parameters. Thus, it is not recommended that values be used interchangeably. The Association for Research in Vision and Ophthalmology 2018-03 /pmc/articles/PMC5863688/ /pubmed/29625479 http://dx.doi.org/10.1167/iovs.17-23574 Text en Copyright 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. |
spellingShingle | Glaucoma Chansangpetch, Sunee Nguyen, Anwell Mora, Marta Badr, Mai He, Mingguang Porco, Travis C. Lin, Shan C. Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography |
title | Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography |
title_full | Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography |
title_fullStr | Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography |
title_full_unstemmed | Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography |
title_short | Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography |
title_sort | agreement of anterior segment parameters obtained from swept-source fourier-domain and time-domain anterior segment optical coherence tomography |
topic | Glaucoma |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5863688/ https://www.ncbi.nlm.nih.gov/pubmed/29625479 http://dx.doi.org/10.1167/iovs.17-23574 |
work_keys_str_mv | AT chansangpetchsunee agreementofanteriorsegmentparametersobtainedfromsweptsourcefourierdomainandtimedomainanteriorsegmentopticalcoherencetomography AT nguyenanwell agreementofanteriorsegmentparametersobtainedfromsweptsourcefourierdomainandtimedomainanteriorsegmentopticalcoherencetomography AT moramarta agreementofanteriorsegmentparametersobtainedfromsweptsourcefourierdomainandtimedomainanteriorsegmentopticalcoherencetomography AT badrmai agreementofanteriorsegmentparametersobtainedfromsweptsourcefourierdomainandtimedomainanteriorsegmentopticalcoherencetomography AT hemingguang agreementofanteriorsegmentparametersobtainedfromsweptsourcefourierdomainandtimedomainanteriorsegmentopticalcoherencetomography AT porcotravisc agreementofanteriorsegmentparametersobtainedfromsweptsourcefourierdomainandtimedomainanteriorsegmentopticalcoherencetomography AT linshanc agreementofanteriorsegmentparametersobtainedfromsweptsourcefourierdomainandtimedomainanteriorsegmentopticalcoherencetomography |