Cargando…

Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography

PURPOSE: To assess the interdevice agreement between swept-source Fourier-domain and time-domain anterior segment optical coherence tomography (AS-OCT). METHODS: Fifty-three eyes from 41 subjects underwent CASIA2 and Visante OCT imaging. One hundred eighty–degree axis images were measured with the b...

Descripción completa

Detalles Bibliográficos
Autores principales: Chansangpetch, Sunee, Nguyen, Anwell, Mora, Marta, Badr, Mai, He, Mingguang, Porco, Travis C., Lin, Shan C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Association for Research in Vision and Ophthalmology 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5863688/
https://www.ncbi.nlm.nih.gov/pubmed/29625479
http://dx.doi.org/10.1167/iovs.17-23574
_version_ 1783308424626307072
author Chansangpetch, Sunee
Nguyen, Anwell
Mora, Marta
Badr, Mai
He, Mingguang
Porco, Travis C.
Lin, Shan C.
author_facet Chansangpetch, Sunee
Nguyen, Anwell
Mora, Marta
Badr, Mai
He, Mingguang
Porco, Travis C.
Lin, Shan C.
author_sort Chansangpetch, Sunee
collection PubMed
description PURPOSE: To assess the interdevice agreement between swept-source Fourier-domain and time-domain anterior segment optical coherence tomography (AS-OCT). METHODS: Fifty-three eyes from 41 subjects underwent CASIA2 and Visante OCT imaging. One hundred eighty–degree axis images were measured with the built-in two-dimensional analysis software for the swept-source Fourier-domain AS-OCT (CASIA2) and a customized program for the time-domain AS-OCT (Visante OCT). In both devices, we examined the angle opening distance (AOD), trabecular iris space area (TISA), angle recess area (ARA), anterior chamber depth (ACD), anterior chamber width (ACW), and lens vault (LV). Bland-Altman plots and intraclass correlation (ICC) were performed. Orthogonal linear regression assessed any proportional bias. RESULTS: ICC showed strong correlation for LV (0.925) and ACD (0.992) and moderate agreement for ACW (0.801). ICC suggested good agreement for all angle parameters (0.771–0.878) except temporal AOD500 (0.743) and ARA750 (nasal 0.481; temporal 0.481). There was a proportional bias in nasal ARA750 (slope 2.44, 95% confidence interval [CI]: 1.95–3.18), temporal ARA750 (slope 2.57, 95% CI: 2.04–3.40), and nasal TISA500 (slope 1.30, 95% CI: 1.12–1.54). Bland-Altman plots demonstrated in all measured parameters a minimal mean difference between the two devices (−0.089 to 0.063); however, evidence of constant bias was found in nasal AOD250, nasal AOD500, nasal AOD750, nasal ARA750, temporal AOD500, temporal AOD750, temporal ARA750, and ACD. Among the parameters with constant biases, CASIA2 tends to give the larger numbers. CONCLUSIONS: Both devices had generally good agreement. However, there were proportional and constant biases in most angle parameters. Thus, it is not recommended that values be used interchangeably.
format Online
Article
Text
id pubmed-5863688
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Association for Research in Vision and Ophthalmology
record_format MEDLINE/PubMed
spelling pubmed-58636882018-03-23 Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography Chansangpetch, Sunee Nguyen, Anwell Mora, Marta Badr, Mai He, Mingguang Porco, Travis C. Lin, Shan C. Invest Ophthalmol Vis Sci Glaucoma PURPOSE: To assess the interdevice agreement between swept-source Fourier-domain and time-domain anterior segment optical coherence tomography (AS-OCT). METHODS: Fifty-three eyes from 41 subjects underwent CASIA2 and Visante OCT imaging. One hundred eighty–degree axis images were measured with the built-in two-dimensional analysis software for the swept-source Fourier-domain AS-OCT (CASIA2) and a customized program for the time-domain AS-OCT (Visante OCT). In both devices, we examined the angle opening distance (AOD), trabecular iris space area (TISA), angle recess area (ARA), anterior chamber depth (ACD), anterior chamber width (ACW), and lens vault (LV). Bland-Altman plots and intraclass correlation (ICC) were performed. Orthogonal linear regression assessed any proportional bias. RESULTS: ICC showed strong correlation for LV (0.925) and ACD (0.992) and moderate agreement for ACW (0.801). ICC suggested good agreement for all angle parameters (0.771–0.878) except temporal AOD500 (0.743) and ARA750 (nasal 0.481; temporal 0.481). There was a proportional bias in nasal ARA750 (slope 2.44, 95% confidence interval [CI]: 1.95–3.18), temporal ARA750 (slope 2.57, 95% CI: 2.04–3.40), and nasal TISA500 (slope 1.30, 95% CI: 1.12–1.54). Bland-Altman plots demonstrated in all measured parameters a minimal mean difference between the two devices (−0.089 to 0.063); however, evidence of constant bias was found in nasal AOD250, nasal AOD500, nasal AOD750, nasal ARA750, temporal AOD500, temporal AOD750, temporal ARA750, and ACD. Among the parameters with constant biases, CASIA2 tends to give the larger numbers. CONCLUSIONS: Both devices had generally good agreement. However, there were proportional and constant biases in most angle parameters. Thus, it is not recommended that values be used interchangeably. The Association for Research in Vision and Ophthalmology 2018-03 /pmc/articles/PMC5863688/ /pubmed/29625479 http://dx.doi.org/10.1167/iovs.17-23574 Text en Copyright 2018 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.
spellingShingle Glaucoma
Chansangpetch, Sunee
Nguyen, Anwell
Mora, Marta
Badr, Mai
He, Mingguang
Porco, Travis C.
Lin, Shan C.
Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography
title Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography
title_full Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography
title_fullStr Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography
title_full_unstemmed Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography
title_short Agreement of Anterior Segment Parameters Obtained From Swept-Source Fourier-Domain and Time-Domain Anterior Segment Optical Coherence Tomography
title_sort agreement of anterior segment parameters obtained from swept-source fourier-domain and time-domain anterior segment optical coherence tomography
topic Glaucoma
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5863688/
https://www.ncbi.nlm.nih.gov/pubmed/29625479
http://dx.doi.org/10.1167/iovs.17-23574
work_keys_str_mv AT chansangpetchsunee agreementofanteriorsegmentparametersobtainedfromsweptsourcefourierdomainandtimedomainanteriorsegmentopticalcoherencetomography
AT nguyenanwell agreementofanteriorsegmentparametersobtainedfromsweptsourcefourierdomainandtimedomainanteriorsegmentopticalcoherencetomography
AT moramarta agreementofanteriorsegmentparametersobtainedfromsweptsourcefourierdomainandtimedomainanteriorsegmentopticalcoherencetomography
AT badrmai agreementofanteriorsegmentparametersobtainedfromsweptsourcefourierdomainandtimedomainanteriorsegmentopticalcoherencetomography
AT hemingguang agreementofanteriorsegmentparametersobtainedfromsweptsourcefourierdomainandtimedomainanteriorsegmentopticalcoherencetomography
AT porcotravisc agreementofanteriorsegmentparametersobtainedfromsweptsourcefourierdomainandtimedomainanteriorsegmentopticalcoherencetomography
AT linshanc agreementofanteriorsegmentparametersobtainedfromsweptsourcefourierdomainandtimedomainanteriorsegmentopticalcoherencetomography