Cargando…
Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia
Thoracoscopic prosthetic repair of congenital diaphragmatic hernia (CDH) is a well-established and safe technique in experienced hands but the patching procedure is technically demanding and time consuming. To address the challenges associated with this process (confined working space and restricted...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Georg Thieme Verlag KG
2018
|
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5864520/ https://www.ncbi.nlm.nih.gov/pubmed/29577002 http://dx.doi.org/10.1055/s-0037-1612618 |
_version_ | 1783308530650972160 |
---|---|
author | Poupalou, Anna Vrancken, Celine Vanderveken, Erwin Steyaert, Henri |
author_facet | Poupalou, Anna Vrancken, Celine Vanderveken, Erwin Steyaert, Henri |
author_sort | Poupalou, Anna |
collection | PubMed |
description | Thoracoscopic prosthetic repair of congenital diaphragmatic hernia (CDH) is a well-established and safe technique in experienced hands but the patching procedure is technically demanding and time consuming. To address the challenges associated with this process (confined working space and restricted time), the aim of this article is to assess the potential improvements in feasibility, efficacy, and safety of patch fixation by using nonabsorbable helicoidal tacks in neonates and infants for the repair of large CDH by thoracoscopy. The new technique has all the advantages of minimal invasive surgery in very young children combined with the advantages of reduced operating time and increased simplicity, and may be a good option in cases of recurrence. |
format | Online Article Text |
id | pubmed-5864520 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Georg Thieme Verlag KG |
record_format | MEDLINE/PubMed |
spelling | pubmed-58645202018-03-23 Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia Poupalou, Anna Vrancken, Celine Vanderveken, Erwin Steyaert, Henri European J Pediatr Surg Rep Thoracoscopic prosthetic repair of congenital diaphragmatic hernia (CDH) is a well-established and safe technique in experienced hands but the patching procedure is technically demanding and time consuming. To address the challenges associated with this process (confined working space and restricted time), the aim of this article is to assess the potential improvements in feasibility, efficacy, and safety of patch fixation by using nonabsorbable helicoidal tacks in neonates and infants for the repair of large CDH by thoracoscopy. The new technique has all the advantages of minimal invasive surgery in very young children combined with the advantages of reduced operating time and increased simplicity, and may be a good option in cases of recurrence. Georg Thieme Verlag KG 2018-01 2018-03-22 /pmc/articles/PMC5864520/ /pubmed/29577002 http://dx.doi.org/10.1055/s-0037-1612618 Text en https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Poupalou, Anna Vrancken, Celine Vanderveken, Erwin Steyaert, Henri Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia |
title | Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia |
title_full | Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia |
title_fullStr | Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia |
title_full_unstemmed | Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia |
title_short | Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia |
title_sort | use of nonabsorbable spiral tacks for mesh reinforcement in thoracoscopic repair of congenital diaphragmatic hernia |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5864520/ https://www.ncbi.nlm.nih.gov/pubmed/29577002 http://dx.doi.org/10.1055/s-0037-1612618 |
work_keys_str_mv | AT poupalouanna useofnonabsorbablespiraltacksformeshreinforcementinthoracoscopicrepairofcongenitaldiaphragmatichernia AT vranckenceline useofnonabsorbablespiraltacksformeshreinforcementinthoracoscopicrepairofcongenitaldiaphragmatichernia AT vandervekenerwin useofnonabsorbablespiraltacksformeshreinforcementinthoracoscopicrepairofcongenitaldiaphragmatichernia AT steyaerthenri useofnonabsorbablespiraltacksformeshreinforcementinthoracoscopicrepairofcongenitaldiaphragmatichernia |