Cargando…

Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia

Thoracoscopic prosthetic repair of congenital diaphragmatic hernia (CDH) is a well-established and safe technique in experienced hands but the patching procedure is technically demanding and time consuming. To address the challenges associated with this process (confined working space and restricted...

Descripción completa

Detalles Bibliográficos
Autores principales: Poupalou, Anna, Vrancken, Celine, Vanderveken, Erwin, Steyaert, Henri
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Georg Thieme Verlag KG 2018
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5864520/
https://www.ncbi.nlm.nih.gov/pubmed/29577002
http://dx.doi.org/10.1055/s-0037-1612618
_version_ 1783308530650972160
author Poupalou, Anna
Vrancken, Celine
Vanderveken, Erwin
Steyaert, Henri
author_facet Poupalou, Anna
Vrancken, Celine
Vanderveken, Erwin
Steyaert, Henri
author_sort Poupalou, Anna
collection PubMed
description Thoracoscopic prosthetic repair of congenital diaphragmatic hernia (CDH) is a well-established and safe technique in experienced hands but the patching procedure is technically demanding and time consuming. To address the challenges associated with this process (confined working space and restricted time), the aim of this article is to assess the potential improvements in feasibility, efficacy, and safety of patch fixation by using nonabsorbable helicoidal tacks in neonates and infants for the repair of large CDH by thoracoscopy. The new technique has all the advantages of minimal invasive surgery in very young children combined with the advantages of reduced operating time and increased simplicity, and may be a good option in cases of recurrence.
format Online
Article
Text
id pubmed-5864520
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Georg Thieme Verlag KG
record_format MEDLINE/PubMed
spelling pubmed-58645202018-03-23 Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia Poupalou, Anna Vrancken, Celine Vanderveken, Erwin Steyaert, Henri European J Pediatr Surg Rep Thoracoscopic prosthetic repair of congenital diaphragmatic hernia (CDH) is a well-established and safe technique in experienced hands but the patching procedure is technically demanding and time consuming. To address the challenges associated with this process (confined working space and restricted time), the aim of this article is to assess the potential improvements in feasibility, efficacy, and safety of patch fixation by using nonabsorbable helicoidal tacks in neonates and infants for the repair of large CDH by thoracoscopy. The new technique has all the advantages of minimal invasive surgery in very young children combined with the advantages of reduced operating time and increased simplicity, and may be a good option in cases of recurrence. Georg Thieme Verlag KG 2018-01 2018-03-22 /pmc/articles/PMC5864520/ /pubmed/29577002 http://dx.doi.org/10.1055/s-0037-1612618 Text en https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Poupalou, Anna
Vrancken, Celine
Vanderveken, Erwin
Steyaert, Henri
Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia
title Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia
title_full Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia
title_fullStr Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia
title_full_unstemmed Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia
title_short Use of Nonabsorbable Spiral Tacks for Mesh Reinforcement in Thoracoscopic Repair of Congenital Diaphragmatic Hernia
title_sort use of nonabsorbable spiral tacks for mesh reinforcement in thoracoscopic repair of congenital diaphragmatic hernia
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5864520/
https://www.ncbi.nlm.nih.gov/pubmed/29577002
http://dx.doi.org/10.1055/s-0037-1612618
work_keys_str_mv AT poupalouanna useofnonabsorbablespiraltacksformeshreinforcementinthoracoscopicrepairofcongenitaldiaphragmatichernia
AT vranckenceline useofnonabsorbablespiraltacksformeshreinforcementinthoracoscopicrepairofcongenitaldiaphragmatichernia
AT vandervekenerwin useofnonabsorbablespiraltacksformeshreinforcementinthoracoscopicrepairofcongenitaldiaphragmatichernia
AT steyaerthenri useofnonabsorbablespiraltacksformeshreinforcementinthoracoscopicrepairofcongenitaldiaphragmatichernia