Cargando…

Increased Incidence of Visual Field Abnormalities as Determined by Frequency Doubling Technology Perimetry in High Computer Users Among Japanese Workers: A Retrospective Cohort Study

BACKGROUND: This retrospective cohort study primarily aimed to investigate the possible association of computer use with visual field abnormalities (VFA) among Japanese workers. METHODS: The study included 2,377 workers (mean age 45.7 [standard deviation, 8.3] years; 2,229 men and 148 women) who ini...

Descripción completa

Detalles Bibliográficos
Autores principales: Nakano, Tadashi, Hayashi, Takeshi, Nakagawa, Toru, Honda, Toru, Owada, Satoshi, Endo, Hitoshi, Tatemichi, Masayuki
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Japan Epidemiological Association 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5865013/
https://www.ncbi.nlm.nih.gov/pubmed/29176274
http://dx.doi.org/10.2188/jea.JE20170004
_version_ 1783308607141445632
author Nakano, Tadashi
Hayashi, Takeshi
Nakagawa, Toru
Honda, Toru
Owada, Satoshi
Endo, Hitoshi
Tatemichi, Masayuki
author_facet Nakano, Tadashi
Hayashi, Takeshi
Nakagawa, Toru
Honda, Toru
Owada, Satoshi
Endo, Hitoshi
Tatemichi, Masayuki
author_sort Nakano, Tadashi
collection PubMed
description BACKGROUND: This retrospective cohort study primarily aimed to investigate the possible association of computer use with visual field abnormalities (VFA) among Japanese workers. METHODS: The study included 2,377 workers (mean age 45.7 [standard deviation, 8.3] years; 2,229 men and 148 women) who initially exhibited no VFA during frequency doubling technology perimetry (FDT) testing. Subjects then underwent annual follow-up FDT testing for 7 years, and VFA were determined using a FDT-test protocol (FDT-VFA). Subjects with FDT-VFA were examined by ophthalmologists. Baseline data about the mean duration of computer use during a 5-year period and refractive errors were obtained via self-administered questionnaire and evaluations for refractive errors (use of eyeglasses or contact lenses), respectively. RESULTS: A Cox proportional hazard analysis demonstrated that heavy computer users (>8 hr/day) had a significantly increased risk of FDT-VFA (hazard ratio [HR] 2.85; 95% confidence interval [CI], 1.26–6.48) relative to light users (<4 hr/day), and this association was strengthened among subjects with refractive errors (HR 4.48; 95% CI, 1.87–10.74). The computer usage history also significantly correlated with FDT-VFA among subject with refractive errors (P < 0.05), and 73.1% of subjects with FDT-VFA and refractive errors were diagnosed with glaucoma or ocular hypertension. CONCLUSIONS: The incidence of FDT-VFA appears to be increased among Japanese workers who are heavy computer users, particularly if they have refractive errors. Further investigations of epidemiology and causality are warranted.
format Online
Article
Text
id pubmed-5865013
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Japan Epidemiological Association
record_format MEDLINE/PubMed
spelling pubmed-58650132018-04-05 Increased Incidence of Visual Field Abnormalities as Determined by Frequency Doubling Technology Perimetry in High Computer Users Among Japanese Workers: A Retrospective Cohort Study Nakano, Tadashi Hayashi, Takeshi Nakagawa, Toru Honda, Toru Owada, Satoshi Endo, Hitoshi Tatemichi, Masayuki J Epidemiol Short Communication BACKGROUND: This retrospective cohort study primarily aimed to investigate the possible association of computer use with visual field abnormalities (VFA) among Japanese workers. METHODS: The study included 2,377 workers (mean age 45.7 [standard deviation, 8.3] years; 2,229 men and 148 women) who initially exhibited no VFA during frequency doubling technology perimetry (FDT) testing. Subjects then underwent annual follow-up FDT testing for 7 years, and VFA were determined using a FDT-test protocol (FDT-VFA). Subjects with FDT-VFA were examined by ophthalmologists. Baseline data about the mean duration of computer use during a 5-year period and refractive errors were obtained via self-administered questionnaire and evaluations for refractive errors (use of eyeglasses or contact lenses), respectively. RESULTS: A Cox proportional hazard analysis demonstrated that heavy computer users (>8 hr/day) had a significantly increased risk of FDT-VFA (hazard ratio [HR] 2.85; 95% confidence interval [CI], 1.26–6.48) relative to light users (<4 hr/day), and this association was strengthened among subjects with refractive errors (HR 4.48; 95% CI, 1.87–10.74). The computer usage history also significantly correlated with FDT-VFA among subject with refractive errors (P < 0.05), and 73.1% of subjects with FDT-VFA and refractive errors were diagnosed with glaucoma or ocular hypertension. CONCLUSIONS: The incidence of FDT-VFA appears to be increased among Japanese workers who are heavy computer users, particularly if they have refractive errors. Further investigations of epidemiology and causality are warranted. Japan Epidemiological Association 2018-04-05 /pmc/articles/PMC5865013/ /pubmed/29176274 http://dx.doi.org/10.2188/jea.JE20170004 Text en © 2017 Tadashi Nakano et al. https://creativecommons.org/licenses/by/4.0/ This is an open access article distributed under the terms of Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Short Communication
Nakano, Tadashi
Hayashi, Takeshi
Nakagawa, Toru
Honda, Toru
Owada, Satoshi
Endo, Hitoshi
Tatemichi, Masayuki
Increased Incidence of Visual Field Abnormalities as Determined by Frequency Doubling Technology Perimetry in High Computer Users Among Japanese Workers: A Retrospective Cohort Study
title Increased Incidence of Visual Field Abnormalities as Determined by Frequency Doubling Technology Perimetry in High Computer Users Among Japanese Workers: A Retrospective Cohort Study
title_full Increased Incidence of Visual Field Abnormalities as Determined by Frequency Doubling Technology Perimetry in High Computer Users Among Japanese Workers: A Retrospective Cohort Study
title_fullStr Increased Incidence of Visual Field Abnormalities as Determined by Frequency Doubling Technology Perimetry in High Computer Users Among Japanese Workers: A Retrospective Cohort Study
title_full_unstemmed Increased Incidence of Visual Field Abnormalities as Determined by Frequency Doubling Technology Perimetry in High Computer Users Among Japanese Workers: A Retrospective Cohort Study
title_short Increased Incidence of Visual Field Abnormalities as Determined by Frequency Doubling Technology Perimetry in High Computer Users Among Japanese Workers: A Retrospective Cohort Study
title_sort increased incidence of visual field abnormalities as determined by frequency doubling technology perimetry in high computer users among japanese workers: a retrospective cohort study
topic Short Communication
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5865013/
https://www.ncbi.nlm.nih.gov/pubmed/29176274
http://dx.doi.org/10.2188/jea.JE20170004
work_keys_str_mv AT nakanotadashi increasedincidenceofvisualfieldabnormalitiesasdeterminedbyfrequencydoublingtechnologyperimetryinhighcomputerusersamongjapaneseworkersaretrospectivecohortstudy
AT hayashitakeshi increasedincidenceofvisualfieldabnormalitiesasdeterminedbyfrequencydoublingtechnologyperimetryinhighcomputerusersamongjapaneseworkersaretrospectivecohortstudy
AT nakagawatoru increasedincidenceofvisualfieldabnormalitiesasdeterminedbyfrequencydoublingtechnologyperimetryinhighcomputerusersamongjapaneseworkersaretrospectivecohortstudy
AT hondatoru increasedincidenceofvisualfieldabnormalitiesasdeterminedbyfrequencydoublingtechnologyperimetryinhighcomputerusersamongjapaneseworkersaretrospectivecohortstudy
AT owadasatoshi increasedincidenceofvisualfieldabnormalitiesasdeterminedbyfrequencydoublingtechnologyperimetryinhighcomputerusersamongjapaneseworkersaretrospectivecohortstudy
AT endohitoshi increasedincidenceofvisualfieldabnormalitiesasdeterminedbyfrequencydoublingtechnologyperimetryinhighcomputerusersamongjapaneseworkersaretrospectivecohortstudy
AT tatemichimasayuki increasedincidenceofvisualfieldabnormalitiesasdeterminedbyfrequencydoublingtechnologyperimetryinhighcomputerusersamongjapaneseworkersaretrospectivecohortstudy