Case Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use

INTRODUCTION: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in whic...

Descripción completa

Detalles Bibliográficos
Autores principales: Subramaniam, Thavakumar, Casserly, Paula
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Mashhad University of Medical Sciences 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5866493/
https://www.ncbi.nlm.nih.gov/pubmed/29594081
_version_ 1783308840033320960
author Subramaniam, Thavakumar
Casserly, Paula
author_facet Subramaniam, Thavakumar
Casserly, Paula
author_sort Subramaniam, Thavakumar
collection PubMed
description INTRODUCTION: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in which the pharyngeal distortion by the LMA cuff resulted in an iatrogenic complication. CASE REPORT: A 38-year-old female with a background of multiple myeloma was referred to the otolaryngology team for an open cervical lymph node biopsy. The patient was in remission after a 2 year post chemotherapy treatment, but now presented with a 4-week history of persistent nodal enlargement. During the elective procedure, pharyngeal distortion from the laryngeal airway mask used for airway management resulted in an iatrogenic pharyngeal injury. This case is reported to highlight the importance of communication between the surgeon and anesthetist about the mode of airway management in open neck surgery. CONCLUSION: Communication between the otolaryngologist and anesthetist is pertinent when selecting the method of airway management in open neck procedures. A LMA should be used with caution during open neck procedures, with the surgeon recognizing the potential for pharyngeal distortion.
format Online
Article
Text
id pubmed-5866493
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Mashhad University of Medical Sciences
record_format MEDLINE/PubMed
spelling pubmed-58664932018-03-28 Case Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use Subramaniam, Thavakumar Casserly, Paula Iran J Otorhinolaryngol Case Report INTRODUCTION: The laryngeal mask airway (LMA) is a safe method to establish airway control during general anaesthesia. In otolaryngology surgery, the use of a LMA is well established in ear surgery; however, the use of a LMA during open neck procedures remains controversial. We report a case in which the pharyngeal distortion by the LMA cuff resulted in an iatrogenic complication. CASE REPORT: A 38-year-old female with a background of multiple myeloma was referred to the otolaryngology team for an open cervical lymph node biopsy. The patient was in remission after a 2 year post chemotherapy treatment, but now presented with a 4-week history of persistent nodal enlargement. During the elective procedure, pharyngeal distortion from the laryngeal airway mask used for airway management resulted in an iatrogenic pharyngeal injury. This case is reported to highlight the importance of communication between the surgeon and anesthetist about the mode of airway management in open neck surgery. CONCLUSION: Communication between the otolaryngologist and anesthetist is pertinent when selecting the method of airway management in open neck procedures. A LMA should be used with caution during open neck procedures, with the surgeon recognizing the potential for pharyngeal distortion. Mashhad University of Medical Sciences 2018-03 /pmc/articles/PMC5866493/ /pubmed/29594081 Text en This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Case Report
Subramaniam, Thavakumar
Casserly, Paula
Case Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use
title Case Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use
title_full Case Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use
title_fullStr Case Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use
title_full_unstemmed Case Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use
title_short Case Report of an open Neck Procedure Complication Associated with Laryngeal Mask Airway Use
title_sort case report of an open neck procedure complication associated with laryngeal mask airway use
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5866493/
https://www.ncbi.nlm.nih.gov/pubmed/29594081
work_keys_str_mv AT subramaniamthavakumar casereportofanopenneckprocedurecomplicationassociatedwithlaryngealmaskairwayuse
AT casserlypaula casereportofanopenneckprocedurecomplicationassociatedwithlaryngealmaskairwayuse