Cargando…

Finite element analysis of biomechanical effects of total ankle arthroplasty on the foot

BACKGROUND: Total ankle arthroplasty is gaining popularity as an alternation to ankle arthrodesis for end-stage ankle arthritis. Owing to the complex anatomical characteristics of the ankle joint, total ankle arthroplasty has higher failure rates. Biomechanical exploration of the effects of total an...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Yan, Li, Zengyong, Wong, Duo Wai-Chi, Cheng, Cheng-Kung, Zhang, Ming
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Chinese Speaking Orthopaedic Society 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5866499/
https://www.ncbi.nlm.nih.gov/pubmed/29662779
http://dx.doi.org/10.1016/j.jot.2017.12.003
_version_ 1783308841422684160
author Wang, Yan
Li, Zengyong
Wong, Duo Wai-Chi
Cheng, Cheng-Kung
Zhang, Ming
author_facet Wang, Yan
Li, Zengyong
Wong, Duo Wai-Chi
Cheng, Cheng-Kung
Zhang, Ming
author_sort Wang, Yan
collection PubMed
description BACKGROUND: Total ankle arthroplasty is gaining popularity as an alternation to ankle arthrodesis for end-stage ankle arthritis. Owing to the complex anatomical characteristics of the ankle joint, total ankle arthroplasty has higher failure rates. Biomechanical exploration of the effects of total ankle arthroplasty on the foot and ankle is imperative for the precaution of postoperative complications. The objectives of this study are (1) to investigate the biomechanical differences of the foot and ankle between the foot with total ankle arthroplasty and the intact foot and (2) to investigate the performance of the three-component ankle prosthesis. METHODS: To understand the loading environment of the inner foot, comprehensive finite element models of an intact foot and a foot with total ankle arthroplasty were developed to simulate the stance phase of gait. Motion analysis on the model subject was conducted to obtain the boundary and loading conditions. The model was validated through comparison of plantar pressure and joint contact pressure between computational prediction and experimental measurement. A pressure mapping system was used to measure the plantar pressure during balanced standing and walking in the motion analysis experiment, and joint contact pressure at the talonavicular joint was measured in a cadaver foot. RESULTS: Plantar pressure, stress distribution in bones and implants and joint contact loading in the two models were compared, and motion of the prosthesis was analysed. Compared with the intact foot model, averaged contact pressure at the medial cuneonavicular joint increased by 67.4% at the second-peak instant. The maximum stress in the metatarsal bones increased by 19.8% and 31.3% at the mid-stance and second-peak instants, respectively. Force that was transmitted in three medial columns was 0.33, 0.53 and 1.15 times of body weight, respectively, at the first-peak, mid-stance and second-peak instants. The range of motion of the prosthetic ankle was constrained in the frontal plane. The lateral side of the prosthesis sustained higher loading than the medial side. CONCLUSION: Total ankle arthroplasty resulted in great increase of contact pressure at the medial cuneonavicular joint, making it sustain the highest contact pressure among all joints in the foot. The motion of the prosthesis was constrained in the frontal plane, and asymmetric loading was distributed in the bearing component of the ankle prosthesis in the mediolateral direction. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: Biomechanical variations resulted from total ankle arthroplasty may contribute to negative postoperative outcomes. The exploration of the biomechanical performance in this study might benefit the surgeons in the determination of surgical protocols to avoid complications. The analysis of the performance of the ankle prosthesis could enhance the knowledge of prosthetic design.
format Online
Article
Text
id pubmed-5866499
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Chinese Speaking Orthopaedic Society
record_format MEDLINE/PubMed
spelling pubmed-58664992018-04-16 Finite element analysis of biomechanical effects of total ankle arthroplasty on the foot Wang, Yan Li, Zengyong Wong, Duo Wai-Chi Cheng, Cheng-Kung Zhang, Ming J Orthop Translat Original Article BACKGROUND: Total ankle arthroplasty is gaining popularity as an alternation to ankle arthrodesis for end-stage ankle arthritis. Owing to the complex anatomical characteristics of the ankle joint, total ankle arthroplasty has higher failure rates. Biomechanical exploration of the effects of total ankle arthroplasty on the foot and ankle is imperative for the precaution of postoperative complications. The objectives of this study are (1) to investigate the biomechanical differences of the foot and ankle between the foot with total ankle arthroplasty and the intact foot and (2) to investigate the performance of the three-component ankle prosthesis. METHODS: To understand the loading environment of the inner foot, comprehensive finite element models of an intact foot and a foot with total ankle arthroplasty were developed to simulate the stance phase of gait. Motion analysis on the model subject was conducted to obtain the boundary and loading conditions. The model was validated through comparison of plantar pressure and joint contact pressure between computational prediction and experimental measurement. A pressure mapping system was used to measure the plantar pressure during balanced standing and walking in the motion analysis experiment, and joint contact pressure at the talonavicular joint was measured in a cadaver foot. RESULTS: Plantar pressure, stress distribution in bones and implants and joint contact loading in the two models were compared, and motion of the prosthesis was analysed. Compared with the intact foot model, averaged contact pressure at the medial cuneonavicular joint increased by 67.4% at the second-peak instant. The maximum stress in the metatarsal bones increased by 19.8% and 31.3% at the mid-stance and second-peak instants, respectively. Force that was transmitted in three medial columns was 0.33, 0.53 and 1.15 times of body weight, respectively, at the first-peak, mid-stance and second-peak instants. The range of motion of the prosthetic ankle was constrained in the frontal plane. The lateral side of the prosthesis sustained higher loading than the medial side. CONCLUSION: Total ankle arthroplasty resulted in great increase of contact pressure at the medial cuneonavicular joint, making it sustain the highest contact pressure among all joints in the foot. The motion of the prosthesis was constrained in the frontal plane, and asymmetric loading was distributed in the bearing component of the ankle prosthesis in the mediolateral direction. THE TRANSLATIONAL POTENTIAL OF THIS ARTICLE: Biomechanical variations resulted from total ankle arthroplasty may contribute to negative postoperative outcomes. The exploration of the biomechanical performance in this study might benefit the surgeons in the determination of surgical protocols to avoid complications. The analysis of the performance of the ankle prosthesis could enhance the knowledge of prosthetic design. Chinese Speaking Orthopaedic Society 2017-12-30 /pmc/articles/PMC5866499/ /pubmed/29662779 http://dx.doi.org/10.1016/j.jot.2017.12.003 Text en © 2017 The Authors http://creativecommons.org/licenses/by-nc-nd/4.0/ This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Original Article
Wang, Yan
Li, Zengyong
Wong, Duo Wai-Chi
Cheng, Cheng-Kung
Zhang, Ming
Finite element analysis of biomechanical effects of total ankle arthroplasty on the foot
title Finite element analysis of biomechanical effects of total ankle arthroplasty on the foot
title_full Finite element analysis of biomechanical effects of total ankle arthroplasty on the foot
title_fullStr Finite element analysis of biomechanical effects of total ankle arthroplasty on the foot
title_full_unstemmed Finite element analysis of biomechanical effects of total ankle arthroplasty on the foot
title_short Finite element analysis of biomechanical effects of total ankle arthroplasty on the foot
title_sort finite element analysis of biomechanical effects of total ankle arthroplasty on the foot
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5866499/
https://www.ncbi.nlm.nih.gov/pubmed/29662779
http://dx.doi.org/10.1016/j.jot.2017.12.003
work_keys_str_mv AT wangyan finiteelementanalysisofbiomechanicaleffectsoftotalanklearthroplastyonthefoot
AT lizengyong finiteelementanalysisofbiomechanicaleffectsoftotalanklearthroplastyonthefoot
AT wongduowaichi finiteelementanalysisofbiomechanicaleffectsoftotalanklearthroplastyonthefoot
AT chengchengkung finiteelementanalysisofbiomechanicaleffectsoftotalanklearthroplastyonthefoot
AT zhangming finiteelementanalysisofbiomechanicaleffectsoftotalanklearthroplastyonthefoot