A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies

OBJECT: The aim of this study is to demonstrate the differences between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stenting device and the Flow Redirection Endoluminal Device (FRED) using a series of bench-top evaluations and optical coherence tomography (OCT) images in a cadave...

Descripción completa

Detalles Bibliográficos
Autores principales: Matsuda, Yoshikazu, Chung, Joonho, Keigher, Kiffon, Lopes, Demetrius
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5869451/
https://www.ncbi.nlm.nih.gov/pubmed/28939583
http://dx.doi.org/10.1136/neurintsurg-2017-013074
_version_ 1783309290254106624
author Matsuda, Yoshikazu
Chung, Joonho
Keigher, Kiffon
Lopes, Demetrius
author_facet Matsuda, Yoshikazu
Chung, Joonho
Keigher, Kiffon
Lopes, Demetrius
author_sort Matsuda, Yoshikazu
collection PubMed
description OBJECT: The aim of this study is to demonstrate the differences between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stenting device and the Flow Redirection Endoluminal Device (FRED) using a series of bench-top evaluations and optical coherence tomography (OCT) images in a cadaveric preparation of the basilar artery. METHODS: The first part of the evaluation was bench-top microscopic documentation of metal coverage for LVIS Blue and FRED stents. OCT images of the cerebral vessels and deployed stents were acquired using OCT intravascular imaging. The stents were deployed from the left posterior cerebral artery to the basilar artery in a fresh frozen cadaver. Wall apposition and the relationship to jailed perforators were evaluated. RESULTS: The metal coverage along the inner curves of the LVIS Blue stent was similar to that along the outer curves of the FRED stent. The LVIS Blue stent cell size was compatible for crossing with the tested microcatheters after deployment of the stent. The LVIS Blue stent showed better wall apposition and less coverage of the perforator than the FRED stent in the cadaver experiment. CONCLUSIONS: LVIS Blue has a good crossing profile for microcatheters, better wall apposition, and less perforator coverage than FRED. These are desirable features in territories with high densities of perforators such as the posterior circulation.
format Online
Article
Text
id pubmed-5869451
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-58694512018-03-28 A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies Matsuda, Yoshikazu Chung, Joonho Keigher, Kiffon Lopes, Demetrius J Neurointerv Surg New Devices OBJECT: The aim of this study is to demonstrate the differences between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stenting device and the Flow Redirection Endoluminal Device (FRED) using a series of bench-top evaluations and optical coherence tomography (OCT) images in a cadaveric preparation of the basilar artery. METHODS: The first part of the evaluation was bench-top microscopic documentation of metal coverage for LVIS Blue and FRED stents. OCT images of the cerebral vessels and deployed stents were acquired using OCT intravascular imaging. The stents were deployed from the left posterior cerebral artery to the basilar artery in a fresh frozen cadaver. Wall apposition and the relationship to jailed perforators were evaluated. RESULTS: The metal coverage along the inner curves of the LVIS Blue stent was similar to that along the outer curves of the FRED stent. The LVIS Blue stent cell size was compatible for crossing with the tested microcatheters after deployment of the stent. The LVIS Blue stent showed better wall apposition and less coverage of the perforator than the FRED stent in the cadaver experiment. CONCLUSIONS: LVIS Blue has a good crossing profile for microcatheters, better wall apposition, and less perforator coverage than FRED. These are desirable features in territories with high densities of perforators such as the posterior circulation. BMJ Publishing Group 2018-03 2017-09-22 /pmc/articles/PMC5869451/ /pubmed/28939583 http://dx.doi.org/10.1136/neurintsurg-2017-013074 Text en Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/ This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/
spellingShingle New Devices
Matsuda, Yoshikazu
Chung, Joonho
Keigher, Kiffon
Lopes, Demetrius
A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies
title A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies
title_full A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies
title_fullStr A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies
title_full_unstemmed A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies
title_short A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies
title_sort comparison between the new low-profile visualized intraluminal support (lvis blue) stent and the flow redirection endoluminal device (fred) in bench-top and cadaver studies
topic New Devices
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5869451/
https://www.ncbi.nlm.nih.gov/pubmed/28939583
http://dx.doi.org/10.1136/neurintsurg-2017-013074
work_keys_str_mv AT matsudayoshikazu acomparisonbetweenthenewlowprofilevisualizedintraluminalsupportlvisbluestentandtheflowredirectionendoluminaldevicefredinbenchtopandcadaverstudies
AT chungjoonho acomparisonbetweenthenewlowprofilevisualizedintraluminalsupportlvisbluestentandtheflowredirectionendoluminaldevicefredinbenchtopandcadaverstudies
AT keigherkiffon acomparisonbetweenthenewlowprofilevisualizedintraluminalsupportlvisbluestentandtheflowredirectionendoluminaldevicefredinbenchtopandcadaverstudies
AT lopesdemetrius acomparisonbetweenthenewlowprofilevisualizedintraluminalsupportlvisbluestentandtheflowredirectionendoluminaldevicefredinbenchtopandcadaverstudies
AT matsudayoshikazu comparisonbetweenthenewlowprofilevisualizedintraluminalsupportlvisbluestentandtheflowredirectionendoluminaldevicefredinbenchtopandcadaverstudies
AT chungjoonho comparisonbetweenthenewlowprofilevisualizedintraluminalsupportlvisbluestentandtheflowredirectionendoluminaldevicefredinbenchtopandcadaverstudies
AT keigherkiffon comparisonbetweenthenewlowprofilevisualizedintraluminalsupportlvisbluestentandtheflowredirectionendoluminaldevicefredinbenchtopandcadaverstudies
AT lopesdemetrius comparisonbetweenthenewlowprofilevisualizedintraluminalsupportlvisbluestentandtheflowredirectionendoluminaldevicefredinbenchtopandcadaverstudies