Cargando…
A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies
OBJECT: The aim of this study is to demonstrate the differences between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stenting device and the Flow Redirection Endoluminal Device (FRED) using a series of bench-top evaluations and optical coherence tomography (OCT) images in a cadave...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5869451/ https://www.ncbi.nlm.nih.gov/pubmed/28939583 http://dx.doi.org/10.1136/neurintsurg-2017-013074 |
_version_ | 1783309290254106624 |
---|---|
author | Matsuda, Yoshikazu Chung, Joonho Keigher, Kiffon Lopes, Demetrius |
author_facet | Matsuda, Yoshikazu Chung, Joonho Keigher, Kiffon Lopes, Demetrius |
author_sort | Matsuda, Yoshikazu |
collection | PubMed |
description | OBJECT: The aim of this study is to demonstrate the differences between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stenting device and the Flow Redirection Endoluminal Device (FRED) using a series of bench-top evaluations and optical coherence tomography (OCT) images in a cadaveric preparation of the basilar artery. METHODS: The first part of the evaluation was bench-top microscopic documentation of metal coverage for LVIS Blue and FRED stents. OCT images of the cerebral vessels and deployed stents were acquired using OCT intravascular imaging. The stents were deployed from the left posterior cerebral artery to the basilar artery in a fresh frozen cadaver. Wall apposition and the relationship to jailed perforators were evaluated. RESULTS: The metal coverage along the inner curves of the LVIS Blue stent was similar to that along the outer curves of the FRED stent. The LVIS Blue stent cell size was compatible for crossing with the tested microcatheters after deployment of the stent. The LVIS Blue stent showed better wall apposition and less coverage of the perforator than the FRED stent in the cadaver experiment. CONCLUSIONS: LVIS Blue has a good crossing profile for microcatheters, better wall apposition, and less perforator coverage than FRED. These are desirable features in territories with high densities of perforators such as the posterior circulation. |
format | Online Article Text |
id | pubmed-5869451 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-58694512018-03-28 A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies Matsuda, Yoshikazu Chung, Joonho Keigher, Kiffon Lopes, Demetrius J Neurointerv Surg New Devices OBJECT: The aim of this study is to demonstrate the differences between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stenting device and the Flow Redirection Endoluminal Device (FRED) using a series of bench-top evaluations and optical coherence tomography (OCT) images in a cadaveric preparation of the basilar artery. METHODS: The first part of the evaluation was bench-top microscopic documentation of metal coverage for LVIS Blue and FRED stents. OCT images of the cerebral vessels and deployed stents were acquired using OCT intravascular imaging. The stents were deployed from the left posterior cerebral artery to the basilar artery in a fresh frozen cadaver. Wall apposition and the relationship to jailed perforators were evaluated. RESULTS: The metal coverage along the inner curves of the LVIS Blue stent was similar to that along the outer curves of the FRED stent. The LVIS Blue stent cell size was compatible for crossing with the tested microcatheters after deployment of the stent. The LVIS Blue stent showed better wall apposition and less coverage of the perforator than the FRED stent in the cadaver experiment. CONCLUSIONS: LVIS Blue has a good crossing profile for microcatheters, better wall apposition, and less perforator coverage than FRED. These are desirable features in territories with high densities of perforators such as the posterior circulation. BMJ Publishing Group 2018-03 2017-09-22 /pmc/articles/PMC5869451/ /pubmed/28939583 http://dx.doi.org/10.1136/neurintsurg-2017-013074 Text en Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/ This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
spellingShingle | New Devices Matsuda, Yoshikazu Chung, Joonho Keigher, Kiffon Lopes, Demetrius A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies |
title | A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies |
title_full | A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies |
title_fullStr | A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies |
title_full_unstemmed | A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies |
title_short | A comparison between the new Low-profile Visualized Intraluminal Support (LVIS Blue) stent and the Flow Redirection Endoluminal Device (FRED) in bench-top and cadaver studies |
title_sort | comparison between the new low-profile visualized intraluminal support (lvis blue) stent and the flow redirection endoluminal device (fred) in bench-top and cadaver studies |
topic | New Devices |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5869451/ https://www.ncbi.nlm.nih.gov/pubmed/28939583 http://dx.doi.org/10.1136/neurintsurg-2017-013074 |
work_keys_str_mv | AT matsudayoshikazu acomparisonbetweenthenewlowprofilevisualizedintraluminalsupportlvisbluestentandtheflowredirectionendoluminaldevicefredinbenchtopandcadaverstudies AT chungjoonho acomparisonbetweenthenewlowprofilevisualizedintraluminalsupportlvisbluestentandtheflowredirectionendoluminaldevicefredinbenchtopandcadaverstudies AT keigherkiffon acomparisonbetweenthenewlowprofilevisualizedintraluminalsupportlvisbluestentandtheflowredirectionendoluminaldevicefredinbenchtopandcadaverstudies AT lopesdemetrius acomparisonbetweenthenewlowprofilevisualizedintraluminalsupportlvisbluestentandtheflowredirectionendoluminaldevicefredinbenchtopandcadaverstudies AT matsudayoshikazu comparisonbetweenthenewlowprofilevisualizedintraluminalsupportlvisbluestentandtheflowredirectionendoluminaldevicefredinbenchtopandcadaverstudies AT chungjoonho comparisonbetweenthenewlowprofilevisualizedintraluminalsupportlvisbluestentandtheflowredirectionendoluminaldevicefredinbenchtopandcadaverstudies AT keigherkiffon comparisonbetweenthenewlowprofilevisualizedintraluminalsupportlvisbluestentandtheflowredirectionendoluminaldevicefredinbenchtopandcadaverstudies AT lopesdemetrius comparisonbetweenthenewlowprofilevisualizedintraluminalsupportlvisbluestentandtheflowredirectionendoluminaldevicefredinbenchtopandcadaverstudies |