Cargando…

Acute thrombus formation on phosphorilcholine surface modified flow diverters

PURPOSE: Thromboembolic complications remain a limitation of flow diverting stents. We hypothesize that phosphorilcholine surface modified flow diverters (Pipeline Flex with Shield Technology, sPED) would have less acute thrombus formation on the device surface compared with the classic Pipeline Emb...

Descripción completa

Detalles Bibliográficos
Autores principales: Marosfoi, Miklos, Clarencon, Frederic, Langan, Erin T, King, Robert M, Brooks, Olivia W, Tamura, Takamisu, Wainwright, John M, Gounis, Matthew J, Vedantham, Srinivasan, Puri, Ajit S
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5869458/
https://www.ncbi.nlm.nih.gov/pubmed/28689183
http://dx.doi.org/10.1136/neurintsurg-2017-013175
_version_ 1783309291866816512
author Marosfoi, Miklos
Clarencon, Frederic
Langan, Erin T
King, Robert M
Brooks, Olivia W
Tamura, Takamisu
Wainwright, John M
Gounis, Matthew J
Vedantham, Srinivasan
Puri, Ajit S
author_facet Marosfoi, Miklos
Clarencon, Frederic
Langan, Erin T
King, Robert M
Brooks, Olivia W
Tamura, Takamisu
Wainwright, John M
Gounis, Matthew J
Vedantham, Srinivasan
Puri, Ajit S
author_sort Marosfoi, Miklos
collection PubMed
description PURPOSE: Thromboembolic complications remain a limitation of flow diverting stents. We hypothesize that phosphorilcholine surface modified flow diverters (Pipeline Flex with Shield Technology, sPED) would have less acute thrombus formation on the device surface compared with the classic Pipeline Embolization device (cPED). METHODS: Elastase-induced aneurysms were created in 40 rabbits and randomly assigned to receive cPED or sPED devices with and without dual antiplatelet therapy (DAPT) (four groups, n=10/group). Angioplasty was performed to enhance apposition and create intimal injury for a pro-thrombotic environment. Both before and after angioplasty, the flow diverter was imaged with intravascular optical coherence tomography. The outcome measure was the number of predefined segments along the implant relative to the location of the aneurysm with a minimum of 0 (no clot formation) and maximum of 3 (all segments with thrombus). Clot formation over the device at ostia of branch arteries was assessed as either present or absent. RESULTS: Following angioplasty, the number of flow diverter segments with clots was significantly associated with the flow diverter (p<0.0001), but not with DAPT (p=0.3872) or aneurysm neck size (p=0.8555). The incidence rate for clots with cPED was 1.72 times more than with sPED. The clots on the flow diverter at the location corresponding to side branch ostia was significantly lower with sPED than with cPED (OR 0.180; 95% CI 0.044 to 0.734; p=0.0168), but was not associated with DAPT (p=0.3198). CONCLUSION: In the rabbit model, phosphorilcholine surface modified flow diverters are associated with less thrombus formation on the surface of the device.
format Online
Article
Text
id pubmed-5869458
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-58694582018-03-28 Acute thrombus formation on phosphorilcholine surface modified flow diverters Marosfoi, Miklos Clarencon, Frederic Langan, Erin T King, Robert M Brooks, Olivia W Tamura, Takamisu Wainwright, John M Gounis, Matthew J Vedantham, Srinivasan Puri, Ajit S J Neurointerv Surg Basic Science PURPOSE: Thromboembolic complications remain a limitation of flow diverting stents. We hypothesize that phosphorilcholine surface modified flow diverters (Pipeline Flex with Shield Technology, sPED) would have less acute thrombus formation on the device surface compared with the classic Pipeline Embolization device (cPED). METHODS: Elastase-induced aneurysms were created in 40 rabbits and randomly assigned to receive cPED or sPED devices with and without dual antiplatelet therapy (DAPT) (four groups, n=10/group). Angioplasty was performed to enhance apposition and create intimal injury for a pro-thrombotic environment. Both before and after angioplasty, the flow diverter was imaged with intravascular optical coherence tomography. The outcome measure was the number of predefined segments along the implant relative to the location of the aneurysm with a minimum of 0 (no clot formation) and maximum of 3 (all segments with thrombus). Clot formation over the device at ostia of branch arteries was assessed as either present or absent. RESULTS: Following angioplasty, the number of flow diverter segments with clots was significantly associated with the flow diverter (p<0.0001), but not with DAPT (p=0.3872) or aneurysm neck size (p=0.8555). The incidence rate for clots with cPED was 1.72 times more than with sPED. The clots on the flow diverter at the location corresponding to side branch ostia was significantly lower with sPED than with cPED (OR 0.180; 95% CI 0.044 to 0.734; p=0.0168), but was not associated with DAPT (p=0.3198). CONCLUSION: In the rabbit model, phosphorilcholine surface modified flow diverters are associated with less thrombus formation on the surface of the device. BMJ Publishing Group 2018-04 2017-07-08 /pmc/articles/PMC5869458/ /pubmed/28689183 http://dx.doi.org/10.1136/neurintsurg-2017-013175 Text en © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted. This is an Open Access article distributed in accordance with the terms of the Creative Commons Attribution (CC BY 4.0) license, which permits others to distribute, remix, adapt and build upon this work, for commercial use, provided the original work is properly cited. See: http://creativecommons.org/licenses/by/4.0/
spellingShingle Basic Science
Marosfoi, Miklos
Clarencon, Frederic
Langan, Erin T
King, Robert M
Brooks, Olivia W
Tamura, Takamisu
Wainwright, John M
Gounis, Matthew J
Vedantham, Srinivasan
Puri, Ajit S
Acute thrombus formation on phosphorilcholine surface modified flow diverters
title Acute thrombus formation on phosphorilcholine surface modified flow diverters
title_full Acute thrombus formation on phosphorilcholine surface modified flow diverters
title_fullStr Acute thrombus formation on phosphorilcholine surface modified flow diverters
title_full_unstemmed Acute thrombus formation on phosphorilcholine surface modified flow diverters
title_short Acute thrombus formation on phosphorilcholine surface modified flow diverters
title_sort acute thrombus formation on phosphorilcholine surface modified flow diverters
topic Basic Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5869458/
https://www.ncbi.nlm.nih.gov/pubmed/28689183
http://dx.doi.org/10.1136/neurintsurg-2017-013175
work_keys_str_mv AT marosfoimiklos acutethrombusformationonphosphorilcholinesurfacemodifiedflowdiverters
AT clarenconfrederic acutethrombusformationonphosphorilcholinesurfacemodifiedflowdiverters
AT langanerint acutethrombusformationonphosphorilcholinesurfacemodifiedflowdiverters
AT kingrobertm acutethrombusformationonphosphorilcholinesurfacemodifiedflowdiverters
AT brooksoliviaw acutethrombusformationonphosphorilcholinesurfacemodifiedflowdiverters
AT tamuratakamisu acutethrombusformationonphosphorilcholinesurfacemodifiedflowdiverters
AT wainwrightjohnm acutethrombusformationonphosphorilcholinesurfacemodifiedflowdiverters
AT gounismatthewj acutethrombusformationonphosphorilcholinesurfacemodifiedflowdiverters
AT vedanthamsrinivasan acutethrombusformationonphosphorilcholinesurfacemodifiedflowdiverters
AT puriajits acutethrombusformationonphosphorilcholinesurfacemodifiedflowdiverters