The FieldTrip-SimBio pipeline for EEG forward solutions
BACKGROUND: Accurately solving the electroencephalography (EEG) forward problem is crucial for precise EEG source analysis. Previous studies have shown that the use of multicompartment head models in combination with the finite element method (FEM) can yield high accuracies both numerically and with...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5870695/ https://www.ncbi.nlm.nih.gov/pubmed/29580236 http://dx.doi.org/10.1186/s12938-018-0463-y |
_version_ | 1783309535815925760 |
---|---|
author | Vorwerk, Johannes Oostenveld, Robert Piastra, Maria Carla Magyari, Lilla Wolters, Carsten H. |
author_facet | Vorwerk, Johannes Oostenveld, Robert Piastra, Maria Carla Magyari, Lilla Wolters, Carsten H. |
author_sort | Vorwerk, Johannes |
collection | PubMed |
description | BACKGROUND: Accurately solving the electroencephalography (EEG) forward problem is crucial for precise EEG source analysis. Previous studies have shown that the use of multicompartment head models in combination with the finite element method (FEM) can yield high accuracies both numerically and with regard to the geometrical approximation of the human head. However, the workload for the generation of multicompartment head models has often been too high and the use of publicly available FEM implementations too complicated for a wider application of FEM in research studies. In this paper, we present a MATLAB-based pipeline that aims to resolve this lack of easy-to-use integrated software solutions. The presented pipeline allows for the easy application of five-compartment head models with the FEM within the FieldTrip toolbox for EEG source analysis. METHODS: The FEM from the SimBio toolbox, more specifically the St. Venant approach, was integrated into the FieldTrip toolbox. We give a short sketch of the implementation and its application, and we perform a source localization of somatosensory evoked potentials (SEPs) using this pipeline. We then evaluate the accuracy that can be achieved using the automatically generated five-compartment hexahedral head model [skin, skull, cerebrospinal fluid (CSF), gray matter, white matter] in comparison to a highly accurate tetrahedral head model that was generated on the basis of a semiautomatic segmentation with very careful and time-consuming manual corrections. RESULTS: The source analysis of the SEP data correctly localizes the P20 component and achieves a high goodness of fit. The subsequent comparison to the highly detailed tetrahedral head model shows that the automatically generated five-compartment head model performs about as well as a highly detailed four-compartment head model (skin, skull, CSF, brain). This is a significant improvement in comparison to a three-compartment head model, which is frequently used in praxis, since the importance of modeling the CSF compartment has been shown in a variety of studies. CONCLUSION: The presented pipeline facilitates the use of five-compartment head models with the FEM for EEG source analysis. The accuracy with which the EEG forward problem can thereby be solved is increased compared to the commonly used three-compartment head models, and more reliable EEG source reconstruction results can be obtained. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12938-018-0463-y) contains supplementary material, which is available to authorized users. |
format | Online Article Text |
id | pubmed-5870695 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-58706952018-03-29 The FieldTrip-SimBio pipeline for EEG forward solutions Vorwerk, Johannes Oostenveld, Robert Piastra, Maria Carla Magyari, Lilla Wolters, Carsten H. Biomed Eng Online Software BACKGROUND: Accurately solving the electroencephalography (EEG) forward problem is crucial for precise EEG source analysis. Previous studies have shown that the use of multicompartment head models in combination with the finite element method (FEM) can yield high accuracies both numerically and with regard to the geometrical approximation of the human head. However, the workload for the generation of multicompartment head models has often been too high and the use of publicly available FEM implementations too complicated for a wider application of FEM in research studies. In this paper, we present a MATLAB-based pipeline that aims to resolve this lack of easy-to-use integrated software solutions. The presented pipeline allows for the easy application of five-compartment head models with the FEM within the FieldTrip toolbox for EEG source analysis. METHODS: The FEM from the SimBio toolbox, more specifically the St. Venant approach, was integrated into the FieldTrip toolbox. We give a short sketch of the implementation and its application, and we perform a source localization of somatosensory evoked potentials (SEPs) using this pipeline. We then evaluate the accuracy that can be achieved using the automatically generated five-compartment hexahedral head model [skin, skull, cerebrospinal fluid (CSF), gray matter, white matter] in comparison to a highly accurate tetrahedral head model that was generated on the basis of a semiautomatic segmentation with very careful and time-consuming manual corrections. RESULTS: The source analysis of the SEP data correctly localizes the P20 component and achieves a high goodness of fit. The subsequent comparison to the highly detailed tetrahedral head model shows that the automatically generated five-compartment head model performs about as well as a highly detailed four-compartment head model (skin, skull, CSF, brain). This is a significant improvement in comparison to a three-compartment head model, which is frequently used in praxis, since the importance of modeling the CSF compartment has been shown in a variety of studies. CONCLUSION: The presented pipeline facilitates the use of five-compartment head models with the FEM for EEG source analysis. The accuracy with which the EEG forward problem can thereby be solved is increased compared to the commonly used three-compartment head models, and more reliable EEG source reconstruction results can be obtained. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1186/s12938-018-0463-y) contains supplementary material, which is available to authorized users. BioMed Central 2018-03-27 /pmc/articles/PMC5870695/ /pubmed/29580236 http://dx.doi.org/10.1186/s12938-018-0463-y Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated. |
spellingShingle | Software Vorwerk, Johannes Oostenveld, Robert Piastra, Maria Carla Magyari, Lilla Wolters, Carsten H. The FieldTrip-SimBio pipeline for EEG forward solutions |
title | The FieldTrip-SimBio pipeline for EEG forward solutions |
title_full | The FieldTrip-SimBio pipeline for EEG forward solutions |
title_fullStr | The FieldTrip-SimBio pipeline for EEG forward solutions |
title_full_unstemmed | The FieldTrip-SimBio pipeline for EEG forward solutions |
title_short | The FieldTrip-SimBio pipeline for EEG forward solutions |
title_sort | fieldtrip-simbio pipeline for eeg forward solutions |
topic | Software |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5870695/ https://www.ncbi.nlm.nih.gov/pubmed/29580236 http://dx.doi.org/10.1186/s12938-018-0463-y |
work_keys_str_mv | AT vorwerkjohannes thefieldtripsimbiopipelineforeegforwardsolutions AT oostenveldrobert thefieldtripsimbiopipelineforeegforwardsolutions AT piastramariacarla thefieldtripsimbiopipelineforeegforwardsolutions AT magyarililla thefieldtripsimbiopipelineforeegforwardsolutions AT wolterscarstenh thefieldtripsimbiopipelineforeegforwardsolutions AT vorwerkjohannes fieldtripsimbiopipelineforeegforwardsolutions AT oostenveldrobert fieldtripsimbiopipelineforeegforwardsolutions AT piastramariacarla fieldtripsimbiopipelineforeegforwardsolutions AT magyarililla fieldtripsimbiopipelineforeegforwardsolutions AT wolterscarstenh fieldtripsimbiopipelineforeegforwardsolutions |