Preterm Infant Feeding: A Mechanistic Comparison between a Vacuum Triggered Novel Teat and Breastfeeding
The goal for preterm infants is to achieve full oral feeds quickly and ultimately progress to full breastfeeding. Supplementary oral feeds are often given when the mother is not available to breastfeed. Bottles typically deliver milk in a different fashion compared to breastfeeding, which is thought...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5872794/ https://www.ncbi.nlm.nih.gov/pubmed/29562703 http://dx.doi.org/10.3390/nu10030376 |
_version_ | 1783309916492005376 |
---|---|
author | Geddes, Donna Kok, Chooi Nancarrow, Kathryn Hepworth, Anna Simmer, Karen |
author_facet | Geddes, Donna Kok, Chooi Nancarrow, Kathryn Hepworth, Anna Simmer, Karen |
author_sort | Geddes, Donna |
collection | PubMed |
description | The goal for preterm infants is to achieve full oral feeds quickly and ultimately progress to full breastfeeding. Supplementary oral feeds are often given when the mother is not available to breastfeed. Bottles typically deliver milk in a different fashion compared to breastfeeding, which is thought to hamper transition to full breastfeeding. The aim of this study was to compare the sucking dynamics of preterm infants fed at the breast to feeding with an experimental novel teat (NT) designed to release milk only upon the application of vacuum. Simultaneous ultrasound imaging of the infant oral cavity and measurement of intra-oral vacuum was performed during a breastfeed and a feed with the NT. Test weighs were used to measure milk intake. Linear mixed effects models were performed to investigate differences by feed type, and simultaneous linear regression was performed to investigate individual patterns. Tongue movement was not different between breastfeeding and the NT. Intra-oral vacuums (median (interquartile range: IQR)) were significantly lower with the NT (Baseline vacuum: −5.8 mmHg (−11.0, 0.1); Peak: 40.0 mmHg (−54.6, −27.1)) compared to breastfeeding (Baseline: −31.1 mmHg (−60.0, −12.7); Peak: −106.2 mmHg (−153.0, −65.5)). Milk intake was significantly higher with the NT (33 mL (22.5, 42.5)) compared to the breastfeed (12 mL (3, 15.5)). The novel teat encouraged a similar tongue action to breastfeeding, and infants transferred a greater volume of milk with the novel teat. Intra-oral vacuums were lower in strength with the novel teat compared to the breast. Use of the novel teat for the training of sucking dynamics in preterm infants has the potential to improve breastfeeding success and requires further investigation. |
format | Online Article Text |
id | pubmed-5872794 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-58727942018-03-30 Preterm Infant Feeding: A Mechanistic Comparison between a Vacuum Triggered Novel Teat and Breastfeeding Geddes, Donna Kok, Chooi Nancarrow, Kathryn Hepworth, Anna Simmer, Karen Nutrients Article The goal for preterm infants is to achieve full oral feeds quickly and ultimately progress to full breastfeeding. Supplementary oral feeds are often given when the mother is not available to breastfeed. Bottles typically deliver milk in a different fashion compared to breastfeeding, which is thought to hamper transition to full breastfeeding. The aim of this study was to compare the sucking dynamics of preterm infants fed at the breast to feeding with an experimental novel teat (NT) designed to release milk only upon the application of vacuum. Simultaneous ultrasound imaging of the infant oral cavity and measurement of intra-oral vacuum was performed during a breastfeed and a feed with the NT. Test weighs were used to measure milk intake. Linear mixed effects models were performed to investigate differences by feed type, and simultaneous linear regression was performed to investigate individual patterns. Tongue movement was not different between breastfeeding and the NT. Intra-oral vacuums (median (interquartile range: IQR)) were significantly lower with the NT (Baseline vacuum: −5.8 mmHg (−11.0, 0.1); Peak: 40.0 mmHg (−54.6, −27.1)) compared to breastfeeding (Baseline: −31.1 mmHg (−60.0, −12.7); Peak: −106.2 mmHg (−153.0, −65.5)). Milk intake was significantly higher with the NT (33 mL (22.5, 42.5)) compared to the breastfeed (12 mL (3, 15.5)). The novel teat encouraged a similar tongue action to breastfeeding, and infants transferred a greater volume of milk with the novel teat. Intra-oral vacuums were lower in strength with the novel teat compared to the breast. Use of the novel teat for the training of sucking dynamics in preterm infants has the potential to improve breastfeeding success and requires further investigation. MDPI 2018-03-19 /pmc/articles/PMC5872794/ /pubmed/29562703 http://dx.doi.org/10.3390/nu10030376 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Geddes, Donna Kok, Chooi Nancarrow, Kathryn Hepworth, Anna Simmer, Karen Preterm Infant Feeding: A Mechanistic Comparison between a Vacuum Triggered Novel Teat and Breastfeeding |
title | Preterm Infant Feeding: A Mechanistic Comparison between a Vacuum Triggered Novel Teat and Breastfeeding |
title_full | Preterm Infant Feeding: A Mechanistic Comparison between a Vacuum Triggered Novel Teat and Breastfeeding |
title_fullStr | Preterm Infant Feeding: A Mechanistic Comparison between a Vacuum Triggered Novel Teat and Breastfeeding |
title_full_unstemmed | Preterm Infant Feeding: A Mechanistic Comparison between a Vacuum Triggered Novel Teat and Breastfeeding |
title_short | Preterm Infant Feeding: A Mechanistic Comparison between a Vacuum Triggered Novel Teat and Breastfeeding |
title_sort | preterm infant feeding: a mechanistic comparison between a vacuum triggered novel teat and breastfeeding |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5872794/ https://www.ncbi.nlm.nih.gov/pubmed/29562703 http://dx.doi.org/10.3390/nu10030376 |
work_keys_str_mv | AT geddesdonna preterminfantfeedingamechanisticcomparisonbetweenavacuumtriggerednovelteatandbreastfeeding AT kokchooi preterminfantfeedingamechanisticcomparisonbetweenavacuumtriggerednovelteatandbreastfeeding AT nancarrowkathryn preterminfantfeedingamechanisticcomparisonbetweenavacuumtriggerednovelteatandbreastfeeding AT hepworthanna preterminfantfeedingamechanisticcomparisonbetweenavacuumtriggerednovelteatandbreastfeeding AT simmerkaren preterminfantfeedingamechanisticcomparisonbetweenavacuumtriggerednovelteatandbreastfeeding |