Cargando…
Norepinephrine versus Ephedrine to Maintain Arterial Blood Pressure during Spinal Anesthesia for Cesarean Delivery: A Prospective Double-blinded Trial
BACKGROUND: Ephedrine was conventionally regarded as the first-choice drug to maintain maternal blood pressure during spinal anesthesia for cesarean delivery, due to its stimulant activity on α- and β-adrenergic receptors. Norepinephrine is a weak β-adrenergic and potent α-adrenergic receptor agonis...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5872901/ https://www.ncbi.nlm.nih.gov/pubmed/29628561 http://dx.doi.org/10.4103/aer.AER_204_17 |
Sumario: | BACKGROUND: Ephedrine was conventionally regarded as the first-choice drug to maintain maternal blood pressure during spinal anesthesia for cesarean delivery, due to its stimulant activity on α- and β-adrenergic receptors. Norepinephrine is a weak β-adrenergic and potent α-adrenergic receptor agonist. Therefore, it may be suitable for maintaining blood pressure with less chronotropic effects compared to ephedrine. PATIENTS AND METHODS: One hundred and forty healthy patients having cesarean delivery under spinal anesthesia were randomized to Group N (n = 61) who received a prophylactic bolus of norepinephrine 5 μg intravenous (i.v.) at the time of intrathecal block or Group E (n = 61) who received a prophylactic bolus of i.v. ephedrine 10 mg. Rescue i.v. bolus interventions of norepinephrine 5 μg or ephedrine 10 mg were given as required to maintain systolic blood pressure. Maternal and fetal hemodynamic variables, Apgar score, and number of boluses of vasopressors used were recorded. RESULTS: The numbers of maternal hypotension and hypertension episodes and the frequency of bradycardia and tachycardia were significantly lower in Group N compared with Group E (P = 0.02, 0.003, 0.0002, and 0.008, respectively). The number of boluses of vasopressors used was also lower in Group N (P = 0.005). Uterine artery pulsatility index was lower in Group N compared to Group E (P = 0.01) when measured 5 min after spinal anesthesia. Moreover, it was higher at 5 min in Group E when compared with the baseline readings in the same group (P = 0.001). CONCLUSIONS: Norepinephrine is a suitable and potent drug to counterbalance the hemodynamic effects of spinal anesthesia during cesarean delivery. |
---|