Wear Behaviours and Oxidation Effects on Different UHMWPE Acetabular Cups Using a Hip Joint Simulator

Given the long-term problem of polyethylene wear, medical interest in the new improved cross-linked polyethylene (XLPE), with or without the adding of vitamin E, has risen. The main aim of this study is to gain further insights into the mutual effects of radiation cross-linking and addition of vitam...

Descripción completa

Detalles Bibliográficos
Autores principales: Affatato, Saverio, Ruggiero, Alessandro, Jaber, Sami Abdel, Merola, Massimiliano, Bracco, Pierangiola
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5873012/
https://www.ncbi.nlm.nih.gov/pubmed/29547536
http://dx.doi.org/10.3390/ma11030433
_version_ 1783309958834552832
author Affatato, Saverio
Ruggiero, Alessandro
Jaber, Sami Abdel
Merola, Massimiliano
Bracco, Pierangiola
author_facet Affatato, Saverio
Ruggiero, Alessandro
Jaber, Sami Abdel
Merola, Massimiliano
Bracco, Pierangiola
author_sort Affatato, Saverio
collection PubMed
description Given the long-term problem of polyethylene wear, medical interest in the new improved cross-linked polyethylene (XLPE), with or without the adding of vitamin E, has risen. The main aim of this study is to gain further insights into the mutual effects of radiation cross-linking and addition of vitamin E on the wear performance of ultra-high-molecular-weight polyethylene (UHMWPE). We tested four different batches of polyethylene (namely, a standard one, a vitamin E-stabilized, and two cross-linked) in a hip joint simulator for five million cycles where bovine calf serum was used as lubricant. The acetabular cups were then analyzed using a confocal profilometer to characterize the surface topography. Moreover; the cups were analyzed by using Fourier Transformed Infrared Spectroscopy and Differential Scanning Calorimetry in order to assess the chemical characteristics of the pristine materials. Comparing the different cups’ configuration, mass loss was found to be higher for standard polyethylene than for the other combinations. Mass loss negatively correlated to the cross-link density of the polyethylenes. None of the tested formulations showed evidence of oxidative degradation. We found no correlation between roughness parameters and wear. Furthermore, we found significantly differences in the wear behavior of all the acetabular cups. XLPEs exhibited lower weight loss, which has potential for reduced wear and decreased osteolysis. However, surface topography revealed smoother surfaces of the standard and vitamin E stabilized polyethylene than on the cross-linked samples. This observation suggests incipient crack generations on the rough and scratched surfaces of the cross-linked polyethylene liners.
format Online
Article
Text
id pubmed-5873012
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-58730122018-03-30 Wear Behaviours and Oxidation Effects on Different UHMWPE Acetabular Cups Using a Hip Joint Simulator Affatato, Saverio Ruggiero, Alessandro Jaber, Sami Abdel Merola, Massimiliano Bracco, Pierangiola Materials (Basel) Article Given the long-term problem of polyethylene wear, medical interest in the new improved cross-linked polyethylene (XLPE), with or without the adding of vitamin E, has risen. The main aim of this study is to gain further insights into the mutual effects of radiation cross-linking and addition of vitamin E on the wear performance of ultra-high-molecular-weight polyethylene (UHMWPE). We tested four different batches of polyethylene (namely, a standard one, a vitamin E-stabilized, and two cross-linked) in a hip joint simulator for five million cycles where bovine calf serum was used as lubricant. The acetabular cups were then analyzed using a confocal profilometer to characterize the surface topography. Moreover; the cups were analyzed by using Fourier Transformed Infrared Spectroscopy and Differential Scanning Calorimetry in order to assess the chemical characteristics of the pristine materials. Comparing the different cups’ configuration, mass loss was found to be higher for standard polyethylene than for the other combinations. Mass loss negatively correlated to the cross-link density of the polyethylenes. None of the tested formulations showed evidence of oxidative degradation. We found no correlation between roughness parameters and wear. Furthermore, we found significantly differences in the wear behavior of all the acetabular cups. XLPEs exhibited lower weight loss, which has potential for reduced wear and decreased osteolysis. However, surface topography revealed smoother surfaces of the standard and vitamin E stabilized polyethylene than on the cross-linked samples. This observation suggests incipient crack generations on the rough and scratched surfaces of the cross-linked polyethylene liners. MDPI 2018-03-16 /pmc/articles/PMC5873012/ /pubmed/29547536 http://dx.doi.org/10.3390/ma11030433 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Affatato, Saverio
Ruggiero, Alessandro
Jaber, Sami Abdel
Merola, Massimiliano
Bracco, Pierangiola
Wear Behaviours and Oxidation Effects on Different UHMWPE Acetabular Cups Using a Hip Joint Simulator
title Wear Behaviours and Oxidation Effects on Different UHMWPE Acetabular Cups Using a Hip Joint Simulator
title_full Wear Behaviours and Oxidation Effects on Different UHMWPE Acetabular Cups Using a Hip Joint Simulator
title_fullStr Wear Behaviours and Oxidation Effects on Different UHMWPE Acetabular Cups Using a Hip Joint Simulator
title_full_unstemmed Wear Behaviours and Oxidation Effects on Different UHMWPE Acetabular Cups Using a Hip Joint Simulator
title_short Wear Behaviours and Oxidation Effects on Different UHMWPE Acetabular Cups Using a Hip Joint Simulator
title_sort wear behaviours and oxidation effects on different uhmwpe acetabular cups using a hip joint simulator
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5873012/
https://www.ncbi.nlm.nih.gov/pubmed/29547536
http://dx.doi.org/10.3390/ma11030433
work_keys_str_mv AT affatatosaverio wearbehavioursandoxidationeffectsondifferentuhmwpeacetabularcupsusingahipjointsimulator
AT ruggieroalessandro wearbehavioursandoxidationeffectsondifferentuhmwpeacetabularcupsusingahipjointsimulator
AT jabersamiabdel wearbehavioursandoxidationeffectsondifferentuhmwpeacetabularcupsusingahipjointsimulator
AT merolamassimiliano wearbehavioursandoxidationeffectsondifferentuhmwpeacetabularcupsusingahipjointsimulator
AT braccopierangiola wearbehavioursandoxidationeffectsondifferentuhmwpeacetabularcupsusingahipjointsimulator