Cargando…

Evaluation of a newly developed chemiluminescence immunoassay for detecting cardiac troponin T

BACKGROUND: To evaluate the performance of a chemiluminescence detection kit for cardiac troponin T (cTnT). METHODS: According to the “Guiding principles on performance analysis of diagnostic reagents in vitro” and the Clinical and Laboratory Standards Institute (CLSI) Guidelines, we assessed the de...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Jingkun, Fang, Yizhen, Li, Peihua, Lin, Huayue, Jin, Hongwei, Gao, Lei, Ge, Shengxiang, Zhang, Zhong‐Ying
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5873270/
https://www.ncbi.nlm.nih.gov/pubmed/28940712
http://dx.doi.org/10.1002/jcla.22311
_version_ 1783310011459436544
author Wang, Jingkun
Fang, Yizhen
Li, Peihua
Lin, Huayue
Jin, Hongwei
Gao, Lei
Ge, Shengxiang
Zhang, Zhong‐Ying
author_facet Wang, Jingkun
Fang, Yizhen
Li, Peihua
Lin, Huayue
Jin, Hongwei
Gao, Lei
Ge, Shengxiang
Zhang, Zhong‐Ying
author_sort Wang, Jingkun
collection PubMed
description BACKGROUND: To evaluate the performance of a chemiluminescence detection kit for cardiac troponin T (cTnT). METHODS: According to the “Guiding principles on performance analysis of diagnostic reagents in vitro” and the Clinical and Laboratory Standards Institute (CLSI) Guidelines, we assessed the detection limit, linear range, reportable range, accuracy, precision, cross reactivity, interference factors, and matrix effect of the kit, and compared these parameters with that of the commercial electrochemiluminescence detection kit for cTnT (Roche). RESULTS: The minimum detection limit of the kit was 0.01 ng/mL. The linear range was 0.01 ng/mL‐25 ng/mL. The reportable range was from 0.01 ng/mL to 100 ng/mL. Precision within the batch was 2.9%‐6.4%, and precision between batches was 6.0%; the accuracy was good and the recovery rate reached 96.2%. The cross‐reaction test demonstrated that there was no reactivity between cTnT and a variety of troponins. Test results deviated by less than ±10% in the presence of hemoglobin ≤1000 μg/mL, bilirubin ≤250 μg/mL, triglycerides ≤11.25 mg/mL, and rheumatoid factor ≤206 U/mL, suggesting that kit results were not significantly interfered with these factors. Results from the matrix‐effect assessment revealed absence of a matrix effect in the tested serum samples. Correlation study revealed that the performance of the kit was very consistent with that of the Roche electrochemiluminescence detection kit (Kappa = 0.900, P < .001) with a high correlation (r = .903, P < .001) and a total matching rate of 95.00%. CONCLUSION: The performance of the evaluated chemiluminescence immunoquantitation kit for cTnT detection was acceptable in all tested parameters, fulfilling requirements for clinical applications.
format Online
Article
Text
id pubmed-5873270
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-58732702018-03-31 Evaluation of a newly developed chemiluminescence immunoassay for detecting cardiac troponin T Wang, Jingkun Fang, Yizhen Li, Peihua Lin, Huayue Jin, Hongwei Gao, Lei Ge, Shengxiang Zhang, Zhong‐Ying J Clin Lab Anal Research Articles BACKGROUND: To evaluate the performance of a chemiluminescence detection kit for cardiac troponin T (cTnT). METHODS: According to the “Guiding principles on performance analysis of diagnostic reagents in vitro” and the Clinical and Laboratory Standards Institute (CLSI) Guidelines, we assessed the detection limit, linear range, reportable range, accuracy, precision, cross reactivity, interference factors, and matrix effect of the kit, and compared these parameters with that of the commercial electrochemiluminescence detection kit for cTnT (Roche). RESULTS: The minimum detection limit of the kit was 0.01 ng/mL. The linear range was 0.01 ng/mL‐25 ng/mL. The reportable range was from 0.01 ng/mL to 100 ng/mL. Precision within the batch was 2.9%‐6.4%, and precision between batches was 6.0%; the accuracy was good and the recovery rate reached 96.2%. The cross‐reaction test demonstrated that there was no reactivity between cTnT and a variety of troponins. Test results deviated by less than ±10% in the presence of hemoglobin ≤1000 μg/mL, bilirubin ≤250 μg/mL, triglycerides ≤11.25 mg/mL, and rheumatoid factor ≤206 U/mL, suggesting that kit results were not significantly interfered with these factors. Results from the matrix‐effect assessment revealed absence of a matrix effect in the tested serum samples. Correlation study revealed that the performance of the kit was very consistent with that of the Roche electrochemiluminescence detection kit (Kappa = 0.900, P < .001) with a high correlation (r = .903, P < .001) and a total matching rate of 95.00%. CONCLUSION: The performance of the evaluated chemiluminescence immunoquantitation kit for cTnT detection was acceptable in all tested parameters, fulfilling requirements for clinical applications. John Wiley and Sons Inc. 2017-09-22 /pmc/articles/PMC5873270/ /pubmed/28940712 http://dx.doi.org/10.1002/jcla.22311 Text en © 2017 The Authors Journal of Clinical Laboratory Analysis Published by Wiley Periodicals, Inc. This is an open access article under the terms of the http://creativecommons.org/licenses/by-nc/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.
spellingShingle Research Articles
Wang, Jingkun
Fang, Yizhen
Li, Peihua
Lin, Huayue
Jin, Hongwei
Gao, Lei
Ge, Shengxiang
Zhang, Zhong‐Ying
Evaluation of a newly developed chemiluminescence immunoassay for detecting cardiac troponin T
title Evaluation of a newly developed chemiluminescence immunoassay for detecting cardiac troponin T
title_full Evaluation of a newly developed chemiluminescence immunoassay for detecting cardiac troponin T
title_fullStr Evaluation of a newly developed chemiluminescence immunoassay for detecting cardiac troponin T
title_full_unstemmed Evaluation of a newly developed chemiluminescence immunoassay for detecting cardiac troponin T
title_short Evaluation of a newly developed chemiluminescence immunoassay for detecting cardiac troponin T
title_sort evaluation of a newly developed chemiluminescence immunoassay for detecting cardiac troponin t
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5873270/
https://www.ncbi.nlm.nih.gov/pubmed/28940712
http://dx.doi.org/10.1002/jcla.22311
work_keys_str_mv AT wangjingkun evaluationofanewlydevelopedchemiluminescenceimmunoassayfordetectingcardiactroponint
AT fangyizhen evaluationofanewlydevelopedchemiluminescenceimmunoassayfordetectingcardiactroponint
AT lipeihua evaluationofanewlydevelopedchemiluminescenceimmunoassayfordetectingcardiactroponint
AT linhuayue evaluationofanewlydevelopedchemiluminescenceimmunoassayfordetectingcardiactroponint
AT jinhongwei evaluationofanewlydevelopedchemiluminescenceimmunoassayfordetectingcardiactroponint
AT gaolei evaluationofanewlydevelopedchemiluminescenceimmunoassayfordetectingcardiactroponint
AT geshengxiang evaluationofanewlydevelopedchemiluminescenceimmunoassayfordetectingcardiactroponint
AT zhangzhongying evaluationofanewlydevelopedchemiluminescenceimmunoassayfordetectingcardiactroponint