Cargando…

Revisiting fetal dose during radiation therapy: evaluating treatment techniques and a custom shield

To create a comprehensive dataset of peripheral dose (PD) measurements from a new generation of linear accelerators with and without the presence of a newly designed fetal shield, PD measurements were performed to evaluate the effects of depth, field size, distance from the field edge, collimator an...

Descripción completa

Detalles Bibliográficos
Autores principales: Owrangi, Amir M., Roberts, Donald A., Covington, Elizabeth L., Hayman, James A., Masi, Kathryn M., Lee, Choonik, Moran, Jean M., Prisciandaro, Joann I.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5874082/
https://www.ncbi.nlm.nih.gov/pubmed/27685109
http://dx.doi.org/10.1120/jacmp.v17i5.6135
_version_ 1783310100317863936
author Owrangi, Amir M.
Roberts, Donald A.
Covington, Elizabeth L.
Hayman, James A.
Masi, Kathryn M.
Lee, Choonik
Moran, Jean M.
Prisciandaro, Joann I.
author_facet Owrangi, Amir M.
Roberts, Donald A.
Covington, Elizabeth L.
Hayman, James A.
Masi, Kathryn M.
Lee, Choonik
Moran, Jean M.
Prisciandaro, Joann I.
author_sort Owrangi, Amir M.
collection PubMed
description To create a comprehensive dataset of peripheral dose (PD) measurements from a new generation of linear accelerators with and without the presence of a newly designed fetal shield, PD measurements were performed to evaluate the effects of depth, field size, distance from the field edge, collimator angle, and beam modifiers for common treatment protocols and modalities. A custom fetal lead shield was designed and made for our department that allows external beam treatments from multiple angles while minimizing the need to adjust the shield during patient treatments. PD measurements were acquired for a comprehensive series of static fields on a stack of Solid Water. Additionally, PDs from various clinically relevant treatment scenarios for pregnant patients were measured using an anthropomorphic phantom that was abutted to a stack of Solid Water. As expected, the PD decreased as the distance from the field edge increased and the field size decreased. On average, a PD reduction was observed when a 90° collimator rotation was applied and/or when the tertiary MLCs and jaws defined the field aperture. However, the effect of the collimator rotation (90° versus 0°) in PD reduction was not found to be clinically significant when the tertiary MLCs were used to define the field aperture. In the presence of both the MLCs and the fetal shield, the PD was reduced by 58% at a distance of 10 cm from the field edge. The newly designed fetal shield may effectively reduce fetal dose and is relatively easy to setup. Due to its design, we are able to use a broad range of treatment techniques and beam angles. We believe the acquired comprehensive PD dataset collected with and without the fetal shield will be useful for treatment teams to estimate fetal dose and help guide decisions on treatment techniques without the need to perform pretreatment phantom measurements. PACS number(s): 87.53.Bn, 87.55.D‐, 87.55.N
format Online
Article
Text
id pubmed-5874082
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-58740822018-04-02 Revisiting fetal dose during radiation therapy: evaluating treatment techniques and a custom shield Owrangi, Amir M. Roberts, Donald A. Covington, Elizabeth L. Hayman, James A. Masi, Kathryn M. Lee, Choonik Moran, Jean M. Prisciandaro, Joann I. J Appl Clin Med Phys Radiation Oncology Physics To create a comprehensive dataset of peripheral dose (PD) measurements from a new generation of linear accelerators with and without the presence of a newly designed fetal shield, PD measurements were performed to evaluate the effects of depth, field size, distance from the field edge, collimator angle, and beam modifiers for common treatment protocols and modalities. A custom fetal lead shield was designed and made for our department that allows external beam treatments from multiple angles while minimizing the need to adjust the shield during patient treatments. PD measurements were acquired for a comprehensive series of static fields on a stack of Solid Water. Additionally, PDs from various clinically relevant treatment scenarios for pregnant patients were measured using an anthropomorphic phantom that was abutted to a stack of Solid Water. As expected, the PD decreased as the distance from the field edge increased and the field size decreased. On average, a PD reduction was observed when a 90° collimator rotation was applied and/or when the tertiary MLCs and jaws defined the field aperture. However, the effect of the collimator rotation (90° versus 0°) in PD reduction was not found to be clinically significant when the tertiary MLCs were used to define the field aperture. In the presence of both the MLCs and the fetal shield, the PD was reduced by 58% at a distance of 10 cm from the field edge. The newly designed fetal shield may effectively reduce fetal dose and is relatively easy to setup. Due to its design, we are able to use a broad range of treatment techniques and beam angles. We believe the acquired comprehensive PD dataset collected with and without the fetal shield will be useful for treatment teams to estimate fetal dose and help guide decisions on treatment techniques without the need to perform pretreatment phantom measurements. PACS number(s): 87.53.Bn, 87.55.D‐, 87.55.N John Wiley and Sons Inc. 2016-09-08 /pmc/articles/PMC5874082/ /pubmed/27685109 http://dx.doi.org/10.1120/jacmp.v17i5.6135 Text en © 2016 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Owrangi, Amir M.
Roberts, Donald A.
Covington, Elizabeth L.
Hayman, James A.
Masi, Kathryn M.
Lee, Choonik
Moran, Jean M.
Prisciandaro, Joann I.
Revisiting fetal dose during radiation therapy: evaluating treatment techniques and a custom shield
title Revisiting fetal dose during radiation therapy: evaluating treatment techniques and a custom shield
title_full Revisiting fetal dose during radiation therapy: evaluating treatment techniques and a custom shield
title_fullStr Revisiting fetal dose during radiation therapy: evaluating treatment techniques and a custom shield
title_full_unstemmed Revisiting fetal dose during radiation therapy: evaluating treatment techniques and a custom shield
title_short Revisiting fetal dose during radiation therapy: evaluating treatment techniques and a custom shield
title_sort revisiting fetal dose during radiation therapy: evaluating treatment techniques and a custom shield
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5874082/
https://www.ncbi.nlm.nih.gov/pubmed/27685109
http://dx.doi.org/10.1120/jacmp.v17i5.6135
work_keys_str_mv AT owrangiamirm revisitingfetaldoseduringradiationtherapyevaluatingtreatmenttechniquesandacustomshield
AT robertsdonalda revisitingfetaldoseduringradiationtherapyevaluatingtreatmenttechniquesandacustomshield
AT covingtonelizabethl revisitingfetaldoseduringradiationtherapyevaluatingtreatmenttechniquesandacustomshield
AT haymanjamesa revisitingfetaldoseduringradiationtherapyevaluatingtreatmenttechniquesandacustomshield
AT masikathrynm revisitingfetaldoseduringradiationtherapyevaluatingtreatmenttechniquesandacustomshield
AT leechoonik revisitingfetaldoseduringradiationtherapyevaluatingtreatmenttechniquesandacustomshield
AT moranjeanm revisitingfetaldoseduringradiationtherapyevaluatingtreatmenttechniquesandacustomshield
AT prisciandarojoanni revisitingfetaldoseduringradiationtherapyevaluatingtreatmenttechniquesandacustomshield