Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy

Chest wall radiation therapy treatment delivery was monitored using a 5 mm thick radiochromic poly(vinyl alcohol) cryogel that also provided buildup material. The cryogels were used to detect positioning errors and measure the impact of shifts for a chest wall treatment that was delivered to a RANDO...

Descripción completa

Detalles Bibliográficos
Autores principales: Eyadeh, Molham M., Weston, Mark A., Juhasz, Janos, Diamond, Kevin R.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5874105/
https://www.ncbi.nlm.nih.gov/pubmed/27685110
http://dx.doi.org/10.1120/jacmp.v17i5.6148
_version_ 1783310105548161024
author Eyadeh, Molham M.
Weston, Mark A.
Juhasz, Janos
Diamond, Kevin R.
author_facet Eyadeh, Molham M.
Weston, Mark A.
Juhasz, Janos
Diamond, Kevin R.
author_sort Eyadeh, Molham M.
collection PubMed
description Chest wall radiation therapy treatment delivery was monitored using a 5 mm thick radiochromic poly(vinyl alcohol) cryogel that also provided buildup material. The cryogels were used to detect positioning errors and measure the impact of shifts for a chest wall treatment that was delivered to a RANDO phantom. The phantom was shifted by [Formula: see text] , and [Formula: see text] from the planned position in the anterior/posterior (A/P) direction; these shifts represent setup errors and the uncertainty associated with lung filling during breath‐hold. The two‐dimensional absolute dose distributions measured in the cryogel at the planned position were compared with the distributions at all shifts from this position using gamma analysis ([Formula: see text] , 10% threshold). For shifts of [Formula: see text] , and [Formula: see text] the passing rates ranged from 94.3% to 95.6%, 74.0% to 78.8%, and 17.5% to 22.5%, respectively. These results are consistent with the same gamma analysis performed on dose planes calculated in the middle of the cryogel and on the phantom surface using our treatment planning system, which ranged from 94.3% to 95.0%, 76.8% to 77.9%, and 23.5% to 24.3%, respectively. The Pinnacle dose planes were then scaled empirically and compared to the cryogel measurements. Using the same gamma metric, the pass rates ranged from 97.0% to 98.4%. The results of this study suggest that cryogels may be used as both a buildup material and to evaluate errors in chest wall treatment positioning during deep‐inspiration breath‐hold delivery. The cryogels are sensitive to A/P chest wall shifts of less than 3 mm, which potentially allows for the detection of clinically relevant errors. PACS number(s): 87.55.km, 87.57.uq
format Online
Article
Text
id pubmed-5874105
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-58741052018-04-02 Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy Eyadeh, Molham M. Weston, Mark A. Juhasz, Janos Diamond, Kevin R. J Appl Clin Med Phys Radiation Oncology Physics Chest wall radiation therapy treatment delivery was monitored using a 5 mm thick radiochromic poly(vinyl alcohol) cryogel that also provided buildup material. The cryogels were used to detect positioning errors and measure the impact of shifts for a chest wall treatment that was delivered to a RANDO phantom. The phantom was shifted by [Formula: see text] , and [Formula: see text] from the planned position in the anterior/posterior (A/P) direction; these shifts represent setup errors and the uncertainty associated with lung filling during breath‐hold. The two‐dimensional absolute dose distributions measured in the cryogel at the planned position were compared with the distributions at all shifts from this position using gamma analysis ([Formula: see text] , 10% threshold). For shifts of [Formula: see text] , and [Formula: see text] the passing rates ranged from 94.3% to 95.6%, 74.0% to 78.8%, and 17.5% to 22.5%, respectively. These results are consistent with the same gamma analysis performed on dose planes calculated in the middle of the cryogel and on the phantom surface using our treatment planning system, which ranged from 94.3% to 95.0%, 76.8% to 77.9%, and 23.5% to 24.3%, respectively. The Pinnacle dose planes were then scaled empirically and compared to the cryogel measurements. Using the same gamma metric, the pass rates ranged from 97.0% to 98.4%. The results of this study suggest that cryogels may be used as both a buildup material and to evaluate errors in chest wall treatment positioning during deep‐inspiration breath‐hold delivery. The cryogels are sensitive to A/P chest wall shifts of less than 3 mm, which potentially allows for the detection of clinically relevant errors. PACS number(s): 87.55.km, 87.57.uq John Wiley and Sons Inc. 2016-09-08 /pmc/articles/PMC5874105/ /pubmed/27685110 http://dx.doi.org/10.1120/jacmp.v17i5.6148 Text en © 2016 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Eyadeh, Molham M.
Weston, Mark A.
Juhasz, Janos
Diamond, Kevin R.
Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy
title Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy
title_full Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy
title_fullStr Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy
title_full_unstemmed Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy
title_short Translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy
title_sort translucent poly(vinyl alcohol) cryogel dosimeters for simultaneous dose buildup and monitoring during chest wall radiation therapy
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5874105/
https://www.ncbi.nlm.nih.gov/pubmed/27685110
http://dx.doi.org/10.1120/jacmp.v17i5.6148
work_keys_str_mv AT eyadehmolhamm translucentpolyvinylalcoholcryogeldosimetersforsimultaneousdosebuildupandmonitoringduringchestwallradiationtherapy
AT westonmarka translucentpolyvinylalcoholcryogeldosimetersforsimultaneousdosebuildupandmonitoringduringchestwallradiationtherapy
AT juhaszjanos translucentpolyvinylalcoholcryogeldosimetersforsimultaneousdosebuildupandmonitoringduringchestwallradiationtherapy
AT diamondkevinr translucentpolyvinylalcoholcryogeldosimetersforsimultaneousdosebuildupandmonitoringduringchestwallradiationtherapy