Cargando…

Investigation on using high‐energy proton beam for total body irradiation (TBI)

This work investigated the possibility of using proton beam for total body irradiation (TBI). We hypothesized the broad‐slow‐rising entrance dose from a monoenergetic proton beam can deliver a uniform dose to patient with varied thickness. Comparing to photon‐based TBI, it would not require any pati...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Miao, Qin, Nan, Jia, Xun, Zou, Wei J., Khan, Atif, Yue, Ning J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5874114/
https://www.ncbi.nlm.nih.gov/pubmed/27685117
http://dx.doi.org/10.1120/jacmp.v17i5.6223
_version_ 1783310107606515712
author Zhang, Miao
Qin, Nan
Jia, Xun
Zou, Wei J.
Khan, Atif
Yue, Ning J.
author_facet Zhang, Miao
Qin, Nan
Jia, Xun
Zou, Wei J.
Khan, Atif
Yue, Ning J.
author_sort Zhang, Miao
collection PubMed
description This work investigated the possibility of using proton beam for total body irradiation (TBI). We hypothesized the broad‐slow‐rising entrance dose from a monoenergetic proton beam can deliver a uniform dose to patient with varied thickness. Comparing to photon‐based TBI, it would not require any patient‐specific compensator or beam spoiler. The hypothesis was first tested by simulating 250 MeV, 275 MeV, and 300 MeV protons irradiating a wedge‐shaped water phantom in a paired opposing arrangement using Monte Carlo (MC) method. To allow [Formula: see text] dose variation, the maximum water equivalent thickness (WET) of a treatable patient separation was 29 cm for 250 MeV proton, and [Formula: see text] for 275 MeV and 300 MeV proton. The compared 6 MV photon can only treat patients with up to 15.5 cm water‐equivalent separation. In the second step, we simulated the dose deposition from the same beams on a patient's whole‐body CT scan. The maximum patient separation in WET was 23 cm. The calculated whole‐body dose variations were [Formula: see text] , [Formula: see text] , and [Formula: see text] for 250 MeV proton, 275 MeV proton, 300 MeV proton, and 6 MV photon. At last, we tested the current machine capability to deliver a monoenergetic proton beam with a large uniform field. Experiments were performed on a compact double scattering single‐gantry proton system. With its C‐shaped gantry design, the source‐to‐surface distance (SSD) reached 7 m. The measured dose deposition curve had 22 cm relatively flat entrance region. The full width half maximum field size was measured 105 cm. The current scatter filter had to be redesigned to produce a uniform intensity at such treatment distance. In conclusion, this work demonstrated the possibility of using proton beam for TBI. The current commercially available proton machines would soon be ready for such task. PACS number(s): 87.53.Bn, 87.55.K‐, 87.55.‐x, 87.56.‐v
format Online
Article
Text
id pubmed-5874114
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-58741142018-04-02 Investigation on using high‐energy proton beam for total body irradiation (TBI) Zhang, Miao Qin, Nan Jia, Xun Zou, Wei J. Khan, Atif Yue, Ning J. J Appl Clin Med Phys Radiation Oncology Physics This work investigated the possibility of using proton beam for total body irradiation (TBI). We hypothesized the broad‐slow‐rising entrance dose from a monoenergetic proton beam can deliver a uniform dose to patient with varied thickness. Comparing to photon‐based TBI, it would not require any patient‐specific compensator or beam spoiler. The hypothesis was first tested by simulating 250 MeV, 275 MeV, and 300 MeV protons irradiating a wedge‐shaped water phantom in a paired opposing arrangement using Monte Carlo (MC) method. To allow [Formula: see text] dose variation, the maximum water equivalent thickness (WET) of a treatable patient separation was 29 cm for 250 MeV proton, and [Formula: see text] for 275 MeV and 300 MeV proton. The compared 6 MV photon can only treat patients with up to 15.5 cm water‐equivalent separation. In the second step, we simulated the dose deposition from the same beams on a patient's whole‐body CT scan. The maximum patient separation in WET was 23 cm. The calculated whole‐body dose variations were [Formula: see text] , [Formula: see text] , and [Formula: see text] for 250 MeV proton, 275 MeV proton, 300 MeV proton, and 6 MV photon. At last, we tested the current machine capability to deliver a monoenergetic proton beam with a large uniform field. Experiments were performed on a compact double scattering single‐gantry proton system. With its C‐shaped gantry design, the source‐to‐surface distance (SSD) reached 7 m. The measured dose deposition curve had 22 cm relatively flat entrance region. The full width half maximum field size was measured 105 cm. The current scatter filter had to be redesigned to produce a uniform intensity at such treatment distance. In conclusion, this work demonstrated the possibility of using proton beam for TBI. The current commercially available proton machines would soon be ready for such task. PACS number(s): 87.53.Bn, 87.55.K‐, 87.55.‐x, 87.56.‐v John Wiley and Sons Inc. 2016-09-08 /pmc/articles/PMC5874114/ /pubmed/27685117 http://dx.doi.org/10.1120/jacmp.v17i5.6223 Text en © 2016 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Zhang, Miao
Qin, Nan
Jia, Xun
Zou, Wei J.
Khan, Atif
Yue, Ning J.
Investigation on using high‐energy proton beam for total body irradiation (TBI)
title Investigation on using high‐energy proton beam for total body irradiation (TBI)
title_full Investigation on using high‐energy proton beam for total body irradiation (TBI)
title_fullStr Investigation on using high‐energy proton beam for total body irradiation (TBI)
title_full_unstemmed Investigation on using high‐energy proton beam for total body irradiation (TBI)
title_short Investigation on using high‐energy proton beam for total body irradiation (TBI)
title_sort investigation on using high‐energy proton beam for total body irradiation (tbi)
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5874114/
https://www.ncbi.nlm.nih.gov/pubmed/27685117
http://dx.doi.org/10.1120/jacmp.v17i5.6223
work_keys_str_mv AT zhangmiao investigationonusinghighenergyprotonbeamfortotalbodyirradiationtbi
AT qinnan investigationonusinghighenergyprotonbeamfortotalbodyirradiationtbi
AT jiaxun investigationonusinghighenergyprotonbeamfortotalbodyirradiationtbi
AT zouweij investigationonusinghighenergyprotonbeamfortotalbodyirradiationtbi
AT khanatif investigationonusinghighenergyprotonbeamfortotalbodyirradiationtbi
AT yueningj investigationonusinghighenergyprotonbeamfortotalbodyirradiationtbi