Method and phantom to study combined effects of in‐plane (x,y) and z‐axis resolution for 3D CT imaging

Increasingly, the advent of multislice CT scanners, volume CT scanners, and total body spiral acquisition modes has led to the use of Multi Planar Reconstruction and 3D datasets. In considering 3D resolution properties of a CT system it is important to note that both the in‐plane (x,y) and z‐axis (s...

Descripción completa

Detalles Bibliográficos
Autores principales: Goodenough, David, Levy, Josh, Kristinsson, Smari, Fredriksson, Jesper, Olafsdottir, Hildur, Healy, Austin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5874118/
https://www.ncbi.nlm.nih.gov/pubmed/27685130
http://dx.doi.org/10.1120/jacmp.v17i5.6294
_version_ 1783310108531359744
author Goodenough, David
Levy, Josh
Kristinsson, Smari
Fredriksson, Jesper
Olafsdottir, Hildur
Healy, Austin
author_facet Goodenough, David
Levy, Josh
Kristinsson, Smari
Fredriksson, Jesper
Olafsdottir, Hildur
Healy, Austin
author_sort Goodenough, David
collection PubMed
description Increasingly, the advent of multislice CT scanners, volume CT scanners, and total body spiral acquisition modes has led to the use of Multi Planar Reconstruction and 3D datasets. In considering 3D resolution properties of a CT system it is important to note that both the in‐plane (x,y) and z‐axis (slice thickness) influence the visualization and detection of objects within the scanned volume. This study investigates ways to consider both the in‐plane resolution and the z‐axis resolution in a single phantom wherein analytic or visualized analysis can yield information on these combined effects. A new phantom called the “Wave Phantom” is developed that can be used to sample the 3D resolution properties of a CT image, including in–plane (x,y) and z‐axis information. The key development in this Wave Phantom is the incorporation of a z‐axis aspect of a more traditional step (bar) resolution gauge phantom. The phantom can be examined visually wherein a cutoff level may be seen; and/or the analytic analysis of the various characteristics of the waveform profile by including amplitude, frequency, and slope (rate of climb) of the peaks, can be extracted from the Wave Pattern using mathematical analysis such as the Fourier transform. The combined effect of changes in in‐plane resolution and z‐axis (thickness), are shown, as well as the effect of changes in either in‐plane resolution, or z‐axis thickness. Examples of visual images of the Wave pattern as well as the analytic characteristics of the various harmonics of a periodic Wave pattern resulting from changes in resolution filter and/or slice thickness, and position in the field of view are shown. The Wave Phantom offers a promising way to investigate 3D resolution results from combined effect of in‐plane (x‐y) and z‐axis resolution as contrasted to the use of simple 2D resolution gauges that need to be used with separate measures of z‐axis dependency, such as angled ramps. It offers both a visual pattern as well as a pattern amenable to analytic analysis using Fourier Transform methods, and is believed to offer an image quality test closer to the diagnostic task where the 2D image has the hidden third (z) axis effects. PACS number(s): 87.57.Q‐
format Online
Article
Text
id pubmed-5874118
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-58741182018-04-02 Method and phantom to study combined effects of in‐plane (x,y) and z‐axis resolution for 3D CT imaging Goodenough, David Levy, Josh Kristinsson, Smari Fredriksson, Jesper Olafsdottir, Hildur Healy, Austin J Appl Clin Med Phys Medical Imaging Increasingly, the advent of multislice CT scanners, volume CT scanners, and total body spiral acquisition modes has led to the use of Multi Planar Reconstruction and 3D datasets. In considering 3D resolution properties of a CT system it is important to note that both the in‐plane (x,y) and z‐axis (slice thickness) influence the visualization and detection of objects within the scanned volume. This study investigates ways to consider both the in‐plane resolution and the z‐axis resolution in a single phantom wherein analytic or visualized analysis can yield information on these combined effects. A new phantom called the “Wave Phantom” is developed that can be used to sample the 3D resolution properties of a CT image, including in–plane (x,y) and z‐axis information. The key development in this Wave Phantom is the incorporation of a z‐axis aspect of a more traditional step (bar) resolution gauge phantom. The phantom can be examined visually wherein a cutoff level may be seen; and/or the analytic analysis of the various characteristics of the waveform profile by including amplitude, frequency, and slope (rate of climb) of the peaks, can be extracted from the Wave Pattern using mathematical analysis such as the Fourier transform. The combined effect of changes in in‐plane resolution and z‐axis (thickness), are shown, as well as the effect of changes in either in‐plane resolution, or z‐axis thickness. Examples of visual images of the Wave pattern as well as the analytic characteristics of the various harmonics of a periodic Wave pattern resulting from changes in resolution filter and/or slice thickness, and position in the field of view are shown. The Wave Phantom offers a promising way to investigate 3D resolution results from combined effect of in‐plane (x‐y) and z‐axis resolution as contrasted to the use of simple 2D resolution gauges that need to be used with separate measures of z‐axis dependency, such as angled ramps. It offers both a visual pattern as well as a pattern amenable to analytic analysis using Fourier Transform methods, and is believed to offer an image quality test closer to the diagnostic task where the 2D image has the hidden third (z) axis effects. PACS number(s): 87.57.Q‐ John Wiley and Sons Inc. 2016-09-08 /pmc/articles/PMC5874118/ /pubmed/27685130 http://dx.doi.org/10.1120/jacmp.v17i5.6294 Text en © 2016 The Authors. This is an open access article under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/3.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Medical Imaging
Goodenough, David
Levy, Josh
Kristinsson, Smari
Fredriksson, Jesper
Olafsdottir, Hildur
Healy, Austin
Method and phantom to study combined effects of in‐plane (x,y) and z‐axis resolution for 3D CT imaging
title Method and phantom to study combined effects of in‐plane (x,y) and z‐axis resolution for 3D CT imaging
title_full Method and phantom to study combined effects of in‐plane (x,y) and z‐axis resolution for 3D CT imaging
title_fullStr Method and phantom to study combined effects of in‐plane (x,y) and z‐axis resolution for 3D CT imaging
title_full_unstemmed Method and phantom to study combined effects of in‐plane (x,y) and z‐axis resolution for 3D CT imaging
title_short Method and phantom to study combined effects of in‐plane (x,y) and z‐axis resolution for 3D CT imaging
title_sort method and phantom to study combined effects of in‐plane (x,y) and z‐axis resolution for 3d ct imaging
topic Medical Imaging
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5874118/
https://www.ncbi.nlm.nih.gov/pubmed/27685130
http://dx.doi.org/10.1120/jacmp.v17i5.6294
work_keys_str_mv AT goodenoughdavid methodandphantomtostudycombinedeffectsofinplanexyandzaxisresolutionfor3dctimaging
AT levyjosh methodandphantomtostudycombinedeffectsofinplanexyandzaxisresolutionfor3dctimaging
AT kristinssonsmari methodandphantomtostudycombinedeffectsofinplanexyandzaxisresolutionfor3dctimaging
AT fredrikssonjesper methodandphantomtostudycombinedeffectsofinplanexyandzaxisresolutionfor3dctimaging
AT olafsdottirhildur methodandphantomtostudycombinedeffectsofinplanexyandzaxisresolutionfor3dctimaging
AT healyaustin methodandphantomtostudycombinedeffectsofinplanexyandzaxisresolutionfor3dctimaging