Cargando…
Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam CT dose estimations
The purpose of this study was to implement full/half bowtie filter models in a commercial treatment planning system (TPS) to calculate kilovoltage (kV) cone‐beam CT (CBCT) doses of Varian On‐Board Imager (OBI) kV X‐ray imaging system. The full/half bowtie filter models were created as compensators i...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2016
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5874958/ https://www.ncbi.nlm.nih.gov/pubmed/27074480 http://dx.doi.org/10.1120/jacmp.v17i2.5988 |
_version_ | 1783310269649256448 |
---|---|
author | Kim, Sangroh Alaei, Parham |
author_facet | Kim, Sangroh Alaei, Parham |
author_sort | Kim, Sangroh |
collection | PubMed |
description | The purpose of this study was to implement full/half bowtie filter models in a commercial treatment planning system (TPS) to calculate kilovoltage (kV) cone‐beam CT (CBCT) doses of Varian On‐Board Imager (OBI) kV X‐ray imaging system. The full/half bowtie filter models were created as compensators in Pinnacle TPS using MATLAB software. The physical profiles of both bowtie filters were imported and hard‐coded in the MATLAB system. Pinnacle scripts were written to import bowtie filter models into Pinnacle treatment plans. Bowtie filter‐free kV X‐ray beam models were commissioned and the bowtie filter models were validated by analyzing the lateral and percent‐depth‐dose (PDD) profiles of anterior/posterior X‐ray beams in water phantoms. A CT dose index (CTDI) phantom was employed to calculate CTDI and weighted CTDI values for pelvis and pelvis‐spotlight CBCT protocols. A five‐year‐old pediatric anthropomorphic phantom was utilized to evaluate absorbed and effective doses (ED) for standard and low‐dose head CBCT protocols. The CBCT dose calculation results were compared to ion chamber (IC) and Monte Carlo (MC) data for the CTDI phantom and MOSFET and MC results for the pediatric phantom, respectively. The differences of lateral and PDD profiles between TPS calculations and IC measurements were within 6%. The CTDI and weighted CTDI values of the TPS were respectively within 0.25 cGy and 0.08 cGy compared to IC measurements. The absorbed doses ranged from 0 to 7.22 cGy for the standard dose CBCT and 0 to 1.56 cGy for the low‐dose CBCT. The ED values were found to be 36‐38 mSv and 7‐8 mSv for the standard and low‐dose CBCT protocols, respectively. This study demonstrated that the established full/half bowtie filter beam models can produce reasonable dose calculation results. Further study is to be performed to evaluate the models in clinical situations. PACS number(s): 87.57.uq |
format | Online Article Text |
id | pubmed-5874958 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2016 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-58749582018-04-02 Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam CT dose estimations Kim, Sangroh Alaei, Parham J Appl Clin Med Phys Radiation Oncology Physics The purpose of this study was to implement full/half bowtie filter models in a commercial treatment planning system (TPS) to calculate kilovoltage (kV) cone‐beam CT (CBCT) doses of Varian On‐Board Imager (OBI) kV X‐ray imaging system. The full/half bowtie filter models were created as compensators in Pinnacle TPS using MATLAB software. The physical profiles of both bowtie filters were imported and hard‐coded in the MATLAB system. Pinnacle scripts were written to import bowtie filter models into Pinnacle treatment plans. Bowtie filter‐free kV X‐ray beam models were commissioned and the bowtie filter models were validated by analyzing the lateral and percent‐depth‐dose (PDD) profiles of anterior/posterior X‐ray beams in water phantoms. A CT dose index (CTDI) phantom was employed to calculate CTDI and weighted CTDI values for pelvis and pelvis‐spotlight CBCT protocols. A five‐year‐old pediatric anthropomorphic phantom was utilized to evaluate absorbed and effective doses (ED) for standard and low‐dose head CBCT protocols. The CBCT dose calculation results were compared to ion chamber (IC) and Monte Carlo (MC) data for the CTDI phantom and MOSFET and MC results for the pediatric phantom, respectively. The differences of lateral and PDD profiles between TPS calculations and IC measurements were within 6%. The CTDI and weighted CTDI values of the TPS were respectively within 0.25 cGy and 0.08 cGy compared to IC measurements. The absorbed doses ranged from 0 to 7.22 cGy for the standard dose CBCT and 0 to 1.56 cGy for the low‐dose CBCT. The ED values were found to be 36‐38 mSv and 7‐8 mSv for the standard and low‐dose CBCT protocols, respectively. This study demonstrated that the established full/half bowtie filter beam models can produce reasonable dose calculation results. Further study is to be performed to evaluate the models in clinical situations. PACS number(s): 87.57.uq John Wiley and Sons Inc. 2016-03-08 /pmc/articles/PMC5874958/ /pubmed/27074480 http://dx.doi.org/10.1120/jacmp.v17i2.5988 Text en © 2016 The Authors. This is an open access article under the terms of the http://creativecommons.org/licenses/by/3.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Kim, Sangroh Alaei, Parham Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam CT dose estimations |
title | Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam CT dose estimations |
title_full | Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam CT dose estimations |
title_fullStr | Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam CT dose estimations |
title_full_unstemmed | Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam CT dose estimations |
title_short | Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam CT dose estimations |
title_sort | implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam ct dose estimations |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5874958/ https://www.ncbi.nlm.nih.gov/pubmed/27074480 http://dx.doi.org/10.1120/jacmp.v17i2.5988 |
work_keys_str_mv | AT kimsangroh implementationoffullhalfbowtiefiltermodelsinacommercialtreatmentplanningsystemforkilovoltageconebeamctdoseestimations AT alaeiparham implementationoffullhalfbowtiefiltermodelsinacommercialtreatmentplanningsystemforkilovoltageconebeamctdoseestimations |