Cargando…

Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam CT dose estimations

The purpose of this study was to implement full/half bowtie filter models in a commercial treatment planning system (TPS) to calculate kilovoltage (kV) cone‐beam CT (CBCT) doses of Varian On‐Board Imager (OBI) kV X‐ray imaging system. The full/half bowtie filter models were created as compensators i...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Sangroh, Alaei, Parham
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2016
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5874958/
https://www.ncbi.nlm.nih.gov/pubmed/27074480
http://dx.doi.org/10.1120/jacmp.v17i2.5988
_version_ 1783310269649256448
author Kim, Sangroh
Alaei, Parham
author_facet Kim, Sangroh
Alaei, Parham
author_sort Kim, Sangroh
collection PubMed
description The purpose of this study was to implement full/half bowtie filter models in a commercial treatment planning system (TPS) to calculate kilovoltage (kV) cone‐beam CT (CBCT) doses of Varian On‐Board Imager (OBI) kV X‐ray imaging system. The full/half bowtie filter models were created as compensators in Pinnacle TPS using MATLAB software. The physical profiles of both bowtie filters were imported and hard‐coded in the MATLAB system. Pinnacle scripts were written to import bowtie filter models into Pinnacle treatment plans. Bowtie filter‐free kV X‐ray beam models were commissioned and the bowtie filter models were validated by analyzing the lateral and percent‐depth‐dose (PDD) profiles of anterior/posterior X‐ray beams in water phantoms. A CT dose index (CTDI) phantom was employed to calculate CTDI and weighted CTDI values for pelvis and pelvis‐spotlight CBCT protocols. A five‐year‐old pediatric anthropomorphic phantom was utilized to evaluate absorbed and effective doses (ED) for standard and low‐dose head CBCT protocols. The CBCT dose calculation results were compared to ion chamber (IC) and Monte Carlo (MC) data for the CTDI phantom and MOSFET and MC results for the pediatric phantom, respectively. The differences of lateral and PDD profiles between TPS calculations and IC measurements were within 6%. The CTDI and weighted CTDI values of the TPS were respectively within 0.25 cGy and 0.08 cGy compared to IC measurements. The absorbed doses ranged from 0 to 7.22 cGy for the standard dose CBCT and 0 to 1.56 cGy for the low‐dose CBCT. The ED values were found to be 36‐38 mSv and 7‐8 mSv for the standard and low‐dose CBCT protocols, respectively. This study demonstrated that the established full/half bowtie filter beam models can produce reasonable dose calculation results. Further study is to be performed to evaluate the models in clinical situations. PACS number(s): 87.57.uq
format Online
Article
Text
id pubmed-5874958
institution National Center for Biotechnology Information
language English
publishDate 2016
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-58749582018-04-02 Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam CT dose estimations Kim, Sangroh Alaei, Parham J Appl Clin Med Phys Radiation Oncology Physics The purpose of this study was to implement full/half bowtie filter models in a commercial treatment planning system (TPS) to calculate kilovoltage (kV) cone‐beam CT (CBCT) doses of Varian On‐Board Imager (OBI) kV X‐ray imaging system. The full/half bowtie filter models were created as compensators in Pinnacle TPS using MATLAB software. The physical profiles of both bowtie filters were imported and hard‐coded in the MATLAB system. Pinnacle scripts were written to import bowtie filter models into Pinnacle treatment plans. Bowtie filter‐free kV X‐ray beam models were commissioned and the bowtie filter models were validated by analyzing the lateral and percent‐depth‐dose (PDD) profiles of anterior/posterior X‐ray beams in water phantoms. A CT dose index (CTDI) phantom was employed to calculate CTDI and weighted CTDI values for pelvis and pelvis‐spotlight CBCT protocols. A five‐year‐old pediatric anthropomorphic phantom was utilized to evaluate absorbed and effective doses (ED) for standard and low‐dose head CBCT protocols. The CBCT dose calculation results were compared to ion chamber (IC) and Monte Carlo (MC) data for the CTDI phantom and MOSFET and MC results for the pediatric phantom, respectively. The differences of lateral and PDD profiles between TPS calculations and IC measurements were within 6%. The CTDI and weighted CTDI values of the TPS were respectively within 0.25 cGy and 0.08 cGy compared to IC measurements. The absorbed doses ranged from 0 to 7.22 cGy for the standard dose CBCT and 0 to 1.56 cGy for the low‐dose CBCT. The ED values were found to be 36‐38 mSv and 7‐8 mSv for the standard and low‐dose CBCT protocols, respectively. This study demonstrated that the established full/half bowtie filter beam models can produce reasonable dose calculation results. Further study is to be performed to evaluate the models in clinical situations. PACS number(s): 87.57.uq John Wiley and Sons Inc. 2016-03-08 /pmc/articles/PMC5874958/ /pubmed/27074480 http://dx.doi.org/10.1120/jacmp.v17i2.5988 Text en © 2016 The Authors. This is an open access article under the terms of the http://creativecommons.org/licenses/by/3.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Kim, Sangroh
Alaei, Parham
Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam CT dose estimations
title Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam CT dose estimations
title_full Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam CT dose estimations
title_fullStr Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam CT dose estimations
title_full_unstemmed Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam CT dose estimations
title_short Implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam CT dose estimations
title_sort implementation of full/half bowtie filter models in a commercial treatment planning system for kilovoltage cone‐beam ct dose estimations
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5874958/
https://www.ncbi.nlm.nih.gov/pubmed/27074480
http://dx.doi.org/10.1120/jacmp.v17i2.5988
work_keys_str_mv AT kimsangroh implementationoffullhalfbowtiefiltermodelsinacommercialtreatmentplanningsystemforkilovoltageconebeamctdoseestimations
AT alaeiparham implementationoffullhalfbowtiefiltermodelsinacommercialtreatmentplanningsystemforkilovoltageconebeamctdoseestimations