Evaluation of radiation dose to organs during kilovoltage cone‐beam computed tomography using Monte Carlo simulation

Image‐guided techniques for radiation therapy have improved the precision of radiation delivery by sparing normal tissues. Cone‐beam computed tomography (CBCT) has emerged as a key technique for patient positioning and target localization in radiotherapy. Here, we investigated the imaging radiation...

Descripción completa

Detalles Bibliográficos
Autores principales: Son, Kihong, Cho, Seungryong, Kim, Jin Sung, Han, Youngyih, Ju, Sang Gyu, Choi, Doo Ho
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2014
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5875477/
https://www.ncbi.nlm.nih.gov/pubmed/24710444
http://dx.doi.org/10.1120/jacmp.v15i2.4556
_version_ 1783310352555966464
author Son, Kihong
Cho, Seungryong
Kim, Jin Sung
Han, Youngyih
Ju, Sang Gyu
Choi, Doo Ho
author_facet Son, Kihong
Cho, Seungryong
Kim, Jin Sung
Han, Youngyih
Ju, Sang Gyu
Choi, Doo Ho
author_sort Son, Kihong
collection PubMed
description Image‐guided techniques for radiation therapy have improved the precision of radiation delivery by sparing normal tissues. Cone‐beam computed tomography (CBCT) has emerged as a key technique for patient positioning and target localization in radiotherapy. Here, we investigated the imaging radiation dose delivered to radiosensitive organs of a patient during CBCT scan. The 4D extended cardiac‐torso (XCAT) phantom and Geant4 Application for Tomographic Emission (GATE) Monte Carlo (MC) simulation tool were used for the study. A computed tomography dose index (CTDI) standard polymethyl methacrylate (PMMA) phantom was used to validate the MC‐based dosimetric evaluation. We implemented an MC model of a clinical on‐board imager integrated with the Trilogy accelerator. The MC model's accuracy was validated by comparing its weighted CTDI (CTDIw) values with those of previous studies, which revealed good agreement. We calculated the absorbed doses of various human organs at different treatment sites such as the head‐and‐neck, chest, abdomen, and pelvis regions, in both standard CBCT scan mode (125 kVp, 80 mA, and 25 ms) and low‐dose scan mode (125 kVp, 40 mA, and 10 ms). In the former mode, the average absorbed doses of the organs in the head and neck and chest regions ranged 4.09‐8.28 cGy, whereas those of the organs in the abdomen and pelvis regions were 4.30‐7.48 cGy. In the latter mode, the absorbed doses of the organs in the head and neck and chest regions ranged 1.61‐1.89 cGy, whereas those of the organs in the abdomen and pelvis region ranged between 0.79‐1.85 cGy. The reduction in the radiation dose in the low‐dose mode compared to the standard mode was about 20%, which is in good agreement with previous reports. We opine that the findings of this study would significantly facilitate decisions regarding the administration of extra imaging doses to radiosensitive organs. PACS number: 87.57.uq
format Online
Article
Text
id pubmed-5875477
institution National Center for Biotechnology Information
language English
publishDate 2014
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-58754772018-04-02 Evaluation of radiation dose to organs during kilovoltage cone‐beam computed tomography using Monte Carlo simulation Son, Kihong Cho, Seungryong Kim, Jin Sung Han, Youngyih Ju, Sang Gyu Choi, Doo Ho J Appl Clin Med Phys Radiation Measurements Image‐guided techniques for radiation therapy have improved the precision of radiation delivery by sparing normal tissues. Cone‐beam computed tomography (CBCT) has emerged as a key technique for patient positioning and target localization in radiotherapy. Here, we investigated the imaging radiation dose delivered to radiosensitive organs of a patient during CBCT scan. The 4D extended cardiac‐torso (XCAT) phantom and Geant4 Application for Tomographic Emission (GATE) Monte Carlo (MC) simulation tool were used for the study. A computed tomography dose index (CTDI) standard polymethyl methacrylate (PMMA) phantom was used to validate the MC‐based dosimetric evaluation. We implemented an MC model of a clinical on‐board imager integrated with the Trilogy accelerator. The MC model's accuracy was validated by comparing its weighted CTDI (CTDIw) values with those of previous studies, which revealed good agreement. We calculated the absorbed doses of various human organs at different treatment sites such as the head‐and‐neck, chest, abdomen, and pelvis regions, in both standard CBCT scan mode (125 kVp, 80 mA, and 25 ms) and low‐dose scan mode (125 kVp, 40 mA, and 10 ms). In the former mode, the average absorbed doses of the organs in the head and neck and chest regions ranged 4.09‐8.28 cGy, whereas those of the organs in the abdomen and pelvis regions were 4.30‐7.48 cGy. In the latter mode, the absorbed doses of the organs in the head and neck and chest regions ranged 1.61‐1.89 cGy, whereas those of the organs in the abdomen and pelvis region ranged between 0.79‐1.85 cGy. The reduction in the radiation dose in the low‐dose mode compared to the standard mode was about 20%, which is in good agreement with previous reports. We opine that the findings of this study would significantly facilitate decisions regarding the administration of extra imaging doses to radiosensitive organs. PACS number: 87.57.uq John Wiley and Sons Inc. 2014-03-06 /pmc/articles/PMC5875477/ /pubmed/24710444 http://dx.doi.org/10.1120/jacmp.v15i2.4556 Text en © 2014 The Authors. This is an open access article under the terms of the http://creativecommons.org/licenses/by/3.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Measurements
Son, Kihong
Cho, Seungryong
Kim, Jin Sung
Han, Youngyih
Ju, Sang Gyu
Choi, Doo Ho
Evaluation of radiation dose to organs during kilovoltage cone‐beam computed tomography using Monte Carlo simulation
title Evaluation of radiation dose to organs during kilovoltage cone‐beam computed tomography using Monte Carlo simulation
title_full Evaluation of radiation dose to organs during kilovoltage cone‐beam computed tomography using Monte Carlo simulation
title_fullStr Evaluation of radiation dose to organs during kilovoltage cone‐beam computed tomography using Monte Carlo simulation
title_full_unstemmed Evaluation of radiation dose to organs during kilovoltage cone‐beam computed tomography using Monte Carlo simulation
title_short Evaluation of radiation dose to organs during kilovoltage cone‐beam computed tomography using Monte Carlo simulation
title_sort evaluation of radiation dose to organs during kilovoltage cone‐beam computed tomography using monte carlo simulation
topic Radiation Measurements
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5875477/
https://www.ncbi.nlm.nih.gov/pubmed/24710444
http://dx.doi.org/10.1120/jacmp.v15i2.4556
work_keys_str_mv AT sonkihong evaluationofradiationdosetoorgansduringkilovoltageconebeamcomputedtomographyusingmontecarlosimulation
AT choseungryong evaluationofradiationdosetoorgansduringkilovoltageconebeamcomputedtomographyusingmontecarlosimulation
AT kimjinsung evaluationofradiationdosetoorgansduringkilovoltageconebeamcomputedtomographyusingmontecarlosimulation
AT hanyoungyih evaluationofradiationdosetoorgansduringkilovoltageconebeamcomputedtomographyusingmontecarlosimulation
AT jusanggyu evaluationofradiationdosetoorgansduringkilovoltageconebeamcomputedtomographyusingmontecarlosimulation
AT choidooho evaluationofradiationdosetoorgansduringkilovoltageconebeamcomputedtomographyusingmontecarlosimulation