Cargando…
Submillimeter alignment of more than three contiguous vertebrae in spinal SRS/SBRT with 6‐degree couch
The purpose of this study is to identify regions of spinal column in which more than three contiguous vertebrae can be reliably and quickly aligned within 1 mm using a 6‐degree (6D) couch and full body immobilization device. We analyzed 45 cases treated over a 3‐month period. Each case was aligned u...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5875814/ https://www.ncbi.nlm.nih.gov/pubmed/28786235 http://dx.doi.org/10.1002/acm2.12153 |
_version_ | 1783310418070994944 |
---|---|
author | Wang, Xin Zhao, Zhongxiang Luo, Dershan Yang, James N. Yang, Jinzhong Chang, Eric L. Brown, Paul D. Li, Jing McAleer, Mary F. Ghia, Amol J. |
author_facet | Wang, Xin Zhao, Zhongxiang Luo, Dershan Yang, James N. Yang, Jinzhong Chang, Eric L. Brown, Paul D. Li, Jing McAleer, Mary F. Ghia, Amol J. |
author_sort | Wang, Xin |
collection | PubMed |
description | The purpose of this study is to identify regions of spinal column in which more than three contiguous vertebrae can be reliably and quickly aligned within 1 mm using a 6‐degree (6D) couch and full body immobilization device. We analyzed 45 cases treated over a 3‐month period. Each case was aligned using ExacTrac x‐ray positioning system with integrated 6D couch to be within 1° and 1 mm in all six dimensions. Cone‐Beam computed tomography (CBCT) with at least 17.5 cm field of view (FOV) in the superior–inferior direction was taken immediately after ExacTrac positioning. It was used to examine the residual error of five to nine contiguous vertebrae visible in the FOV. The residual error of each vertebra was determined by expanding/contracting the vertebrae contour with a margin in millimeter integrals on the planning CT such that the new contours would enclose the corresponding vertebrae contour on CBCT. Submillimeter initial setup accuracy was consistently achieved in 98% (40/41) cases for a span of five or more vertebrae starting from T2 vertebra and extending caudally to S5. The curvature of spinal column along the cervical region and cervicothoracic junction was not easily reproducible between treatment and simulation. Fifty‐seven percent (8/14) of cases in this region had residual setup error of more than 1 mm in nearby vertebrae after alignment using 6D couch with image guidance. In conclusion, 6D couch integrated with image guidance is convenient and accurately corrects small rotational shifts. Consequently, more than three contiguous vertebrae can be aligned within 1 mm with immobilization that reliably reproduces the curvature of the thoracic and lumbar spinal column. Ability of accurate setup is becoming less a concern in limiting the use of stereotactic radiosurgery or stereotactic body radiation therapy to treat multilevel spinal target. |
format | Online Article Text |
id | pubmed-5875814 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-58758142018-04-02 Submillimeter alignment of more than three contiguous vertebrae in spinal SRS/SBRT with 6‐degree couch Wang, Xin Zhao, Zhongxiang Luo, Dershan Yang, James N. Yang, Jinzhong Chang, Eric L. Brown, Paul D. Li, Jing McAleer, Mary F. Ghia, Amol J. J Appl Clin Med Phys Radiation Oncology Physics The purpose of this study is to identify regions of spinal column in which more than three contiguous vertebrae can be reliably and quickly aligned within 1 mm using a 6‐degree (6D) couch and full body immobilization device. We analyzed 45 cases treated over a 3‐month period. Each case was aligned using ExacTrac x‐ray positioning system with integrated 6D couch to be within 1° and 1 mm in all six dimensions. Cone‐Beam computed tomography (CBCT) with at least 17.5 cm field of view (FOV) in the superior–inferior direction was taken immediately after ExacTrac positioning. It was used to examine the residual error of five to nine contiguous vertebrae visible in the FOV. The residual error of each vertebra was determined by expanding/contracting the vertebrae contour with a margin in millimeter integrals on the planning CT such that the new contours would enclose the corresponding vertebrae contour on CBCT. Submillimeter initial setup accuracy was consistently achieved in 98% (40/41) cases for a span of five or more vertebrae starting from T2 vertebra and extending caudally to S5. The curvature of spinal column along the cervical region and cervicothoracic junction was not easily reproducible between treatment and simulation. Fifty‐seven percent (8/14) of cases in this region had residual setup error of more than 1 mm in nearby vertebrae after alignment using 6D couch with image guidance. In conclusion, 6D couch integrated with image guidance is convenient and accurately corrects small rotational shifts. Consequently, more than three contiguous vertebrae can be aligned within 1 mm with immobilization that reliably reproduces the curvature of the thoracic and lumbar spinal column. Ability of accurate setup is becoming less a concern in limiting the use of stereotactic radiosurgery or stereotactic body radiation therapy to treat multilevel spinal target. John Wiley and Sons Inc. 2017-08-08 /pmc/articles/PMC5875814/ /pubmed/28786235 http://dx.doi.org/10.1002/acm2.12153 Text en © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Wang, Xin Zhao, Zhongxiang Luo, Dershan Yang, James N. Yang, Jinzhong Chang, Eric L. Brown, Paul D. Li, Jing McAleer, Mary F. Ghia, Amol J. Submillimeter alignment of more than three contiguous vertebrae in spinal SRS/SBRT with 6‐degree couch |
title | Submillimeter alignment of more than three contiguous vertebrae in spinal SRS/SBRT with 6‐degree couch |
title_full | Submillimeter alignment of more than three contiguous vertebrae in spinal SRS/SBRT with 6‐degree couch |
title_fullStr | Submillimeter alignment of more than three contiguous vertebrae in spinal SRS/SBRT with 6‐degree couch |
title_full_unstemmed | Submillimeter alignment of more than three contiguous vertebrae in spinal SRS/SBRT with 6‐degree couch |
title_short | Submillimeter alignment of more than three contiguous vertebrae in spinal SRS/SBRT with 6‐degree couch |
title_sort | submillimeter alignment of more than three contiguous vertebrae in spinal srs/sbrt with 6‐degree couch |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5875814/ https://www.ncbi.nlm.nih.gov/pubmed/28786235 http://dx.doi.org/10.1002/acm2.12153 |
work_keys_str_mv | AT wangxin submillimeteralignmentofmorethanthreecontiguousvertebraeinspinalsrssbrtwith6degreecouch AT zhaozhongxiang submillimeteralignmentofmorethanthreecontiguousvertebraeinspinalsrssbrtwith6degreecouch AT luodershan submillimeteralignmentofmorethanthreecontiguousvertebraeinspinalsrssbrtwith6degreecouch AT yangjamesn submillimeteralignmentofmorethanthreecontiguousvertebraeinspinalsrssbrtwith6degreecouch AT yangjinzhong submillimeteralignmentofmorethanthreecontiguousvertebraeinspinalsrssbrtwith6degreecouch AT changericl submillimeteralignmentofmorethanthreecontiguousvertebraeinspinalsrssbrtwith6degreecouch AT brownpauld submillimeteralignmentofmorethanthreecontiguousvertebraeinspinalsrssbrtwith6degreecouch AT lijing submillimeteralignmentofmorethanthreecontiguousvertebraeinspinalsrssbrtwith6degreecouch AT mcaleermaryf submillimeteralignmentofmorethanthreecontiguousvertebraeinspinalsrssbrtwith6degreecouch AT ghiaamolj submillimeteralignmentofmorethanthreecontiguousvertebraeinspinalsrssbrtwith6degreecouch |