Technical Note: Monte Carlo calculations of the AAPM TG‐43 brachytherapy dosimetry parameters for a new titanium‐encapsulated Yb‐169 source

Due to a number of distinct advantages resulting from the relatively low energy gamma ray spectrum of Yb‐169, various designs of Yb‐169 sources have been developed over the years for brachytherapy applications. Lately, Yb‐169 has also been suggested as an effective and practical radioisotope option...

Descripción completa

Detalles Bibliográficos
Autores principales: Reynoso, Francisco J., Munro III, John J., Cho, Sang Hyun
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5875832/
https://www.ncbi.nlm.nih.gov/pubmed/28585277
http://dx.doi.org/10.1002/acm2.12111
_version_ 1783310422078652416
author Reynoso, Francisco J.
Munro III, John J.
Cho, Sang Hyun
author_facet Reynoso, Francisco J.
Munro III, John J.
Cho, Sang Hyun
author_sort Reynoso, Francisco J.
collection PubMed
description Due to a number of distinct advantages resulting from the relatively low energy gamma ray spectrum of Yb‐169, various designs of Yb‐169 sources have been developed over the years for brachytherapy applications. Lately, Yb‐169 has also been suggested as an effective and practical radioisotope option for a novel radiation treatment approach often known as gold nanoparticle‐aided radiation therapy (GNRT). In a recently published study, the current investigators used the Monte Carlo N‐Particle Version 5 (MCNP5) code to design a novel titanium‐encapsulated Yb‐169 source optimized for GNRT applications. In this study, the original MC source model was modified to accurately match the specifications of the manufactured Yb‐169 source. The modified MC model was then used to obtain a complete set of the AAPM TG‐43 parameters for the new titanium‐encapsulated Yb‐169 source. The MC‐calculated dose rate constant for this titanium‐encapsulated Yb‐169 source was 1.19 ± 0.03 [Formula: see text] , indicating no significant change from the values reported for stainless steel‐encapsulated Yb‐169 sources. The source anisotropy and radial dose function for the new source were also found similar to those reported for the stainless steel‐encapsulated Yb‐169 sources. The current results suggest that the use of titanium, instead of stainless steel, to encapsulate the Yb‐169 core would not lead to any major change in the dosimetric characteristics of the Yb‐169 source. The results also show that the titanium encapsulation of the Yb‐169 source could be accomplished while meeting the design goals as described in the current investigators’ published MC optimization study for GNRT applications.
format Online
Article
Text
id pubmed-5875832
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-58758322018-04-02 Technical Note: Monte Carlo calculations of the AAPM TG‐43 brachytherapy dosimetry parameters for a new titanium‐encapsulated Yb‐169 source Reynoso, Francisco J. Munro III, John J. Cho, Sang Hyun J Appl Clin Med Phys Radiation Oncology Physics Due to a number of distinct advantages resulting from the relatively low energy gamma ray spectrum of Yb‐169, various designs of Yb‐169 sources have been developed over the years for brachytherapy applications. Lately, Yb‐169 has also been suggested as an effective and practical radioisotope option for a novel radiation treatment approach often known as gold nanoparticle‐aided radiation therapy (GNRT). In a recently published study, the current investigators used the Monte Carlo N‐Particle Version 5 (MCNP5) code to design a novel titanium‐encapsulated Yb‐169 source optimized for GNRT applications. In this study, the original MC source model was modified to accurately match the specifications of the manufactured Yb‐169 source. The modified MC model was then used to obtain a complete set of the AAPM TG‐43 parameters for the new titanium‐encapsulated Yb‐169 source. The MC‐calculated dose rate constant for this titanium‐encapsulated Yb‐169 source was 1.19 ± 0.03 [Formula: see text] , indicating no significant change from the values reported for stainless steel‐encapsulated Yb‐169 sources. The source anisotropy and radial dose function for the new source were also found similar to those reported for the stainless steel‐encapsulated Yb‐169 sources. The current results suggest that the use of titanium, instead of stainless steel, to encapsulate the Yb‐169 core would not lead to any major change in the dosimetric characteristics of the Yb‐169 source. The results also show that the titanium encapsulation of the Yb‐169 source could be accomplished while meeting the design goals as described in the current investigators’ published MC optimization study for GNRT applications. John Wiley and Sons Inc. 2017-06-06 /pmc/articles/PMC5875832/ /pubmed/28585277 http://dx.doi.org/10.1002/acm2.12111 Text en © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Radiation Oncology Physics
Reynoso, Francisco J.
Munro III, John J.
Cho, Sang Hyun
Technical Note: Monte Carlo calculations of the AAPM TG‐43 brachytherapy dosimetry parameters for a new titanium‐encapsulated Yb‐169 source
title Technical Note: Monte Carlo calculations of the AAPM TG‐43 brachytherapy dosimetry parameters for a new titanium‐encapsulated Yb‐169 source
title_full Technical Note: Monte Carlo calculations of the AAPM TG‐43 brachytherapy dosimetry parameters for a new titanium‐encapsulated Yb‐169 source
title_fullStr Technical Note: Monte Carlo calculations of the AAPM TG‐43 brachytherapy dosimetry parameters for a new titanium‐encapsulated Yb‐169 source
title_full_unstemmed Technical Note: Monte Carlo calculations of the AAPM TG‐43 brachytherapy dosimetry parameters for a new titanium‐encapsulated Yb‐169 source
title_short Technical Note: Monte Carlo calculations of the AAPM TG‐43 brachytherapy dosimetry parameters for a new titanium‐encapsulated Yb‐169 source
title_sort technical note: monte carlo calculations of the aapm tg‐43 brachytherapy dosimetry parameters for a new titanium‐encapsulated yb‐169 source
topic Radiation Oncology Physics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5875832/
https://www.ncbi.nlm.nih.gov/pubmed/28585277
http://dx.doi.org/10.1002/acm2.12111
work_keys_str_mv AT reynosofranciscoj technicalnotemontecarlocalculationsoftheaapmtg43brachytherapydosimetryparametersforanewtitaniumencapsulatedyb169source
AT munroiiijohnj technicalnotemontecarlocalculationsoftheaapmtg43brachytherapydosimetryparametersforanewtitaniumencapsulatedyb169source
AT chosanghyun technicalnotemontecarlocalculationsoftheaapmtg43brachytherapydosimetryparametersforanewtitaniumencapsulatedyb169source