Technical note: TROG 15.01 SPARK trial multi‐institutional imaging dose measurement

PURPOSE: The Trans‐Tasman Radiation Oncology Group (TROG) 15.01 Stereotactic Prostate Adaptive Radiotherapy utilizing Kilovoltage intrafraction monitoring (SPARK) trial is a multicenter trial using Kilovoltage Intrafraction Monitoring (KIM) to monitor prostate position during the delivery of prostat...

Descripción completa

Detalles Bibliográficos
Autores principales: Legge, Kimberley, Greer, Peter B., Keall, Paul J., Booth, Jeremy T., Arumugam, Sankar, Moodie, Trevor, Nguyen, Doan T., Martin, Jarad, O'Connor, Daryl John, Lehmann, Joerg
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5875840/
https://www.ncbi.nlm.nih.gov/pubmed/28766904
http://dx.doi.org/10.1002/acm2.12151
_version_ 1783310423516250112
author Legge, Kimberley
Greer, Peter B.
Keall, Paul J.
Booth, Jeremy T.
Arumugam, Sankar
Moodie, Trevor
Nguyen, Doan T.
Martin, Jarad
O'Connor, Daryl John
Lehmann, Joerg
author_facet Legge, Kimberley
Greer, Peter B.
Keall, Paul J.
Booth, Jeremy T.
Arumugam, Sankar
Moodie, Trevor
Nguyen, Doan T.
Martin, Jarad
O'Connor, Daryl John
Lehmann, Joerg
author_sort Legge, Kimberley
collection PubMed
description PURPOSE: The Trans‐Tasman Radiation Oncology Group (TROG) 15.01 Stereotactic Prostate Adaptive Radiotherapy utilizing Kilovoltage intrafraction monitoring (SPARK) trial is a multicenter trial using Kilovoltage Intrafraction Monitoring (KIM) to monitor prostate position during the delivery of prostate radiation therapy. KIM increases the accuracy of prostate radiation therapy treatments and allows for hypofractionation. However, an additional imaging dose is delivered to the patient. A standardized procedure to determine the imaging dose per frame delivered using KIM was developed and applied at four radiation therapy centers on three different types of linear accelerator. METHODS: Dose per frame for kilovoltage imaging in fluoroscopy mode was measured in air at isocenter using an ion chamber. Beam quality and dose were determined for a Varian Clinac iX linear accelerator, a Varian Trilogy, four Varian Truebeams and one Elekta Synergy at four different radiation therapy centers. The imaging parameters used on the Varian machines were 125 kV, 80 mA, and 13 ms. The Elekta machine was measured at 120 kV, 80 mA, and 12 ms. Absorbed doses to the skin and the prostate for a typical SBRT prostate treatment length were estimated according to the IPEMB protocol. RESULTS: The average dose per kV frame to the skin was 0.24 ± 0.03 mGy. The average estimated absorbed dose to the prostate for all five treatment fractions across all machines measured was 39.9 ± 2.6 mGy for 1 Hz imaging, 199.7 ± 13.2 mGy for 5 Hz imaging and 439.3 ± 29.0 mGy for 11 Hz imaging. CONCLUSIONS: All machines measured agreed to within 20%. Additional dose to the prostate from using KIM is at most 1.3% of the prescribed dose of 36.25 Gy in five fractions delivered during the trial.
format Online
Article
Text
id pubmed-5875840
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-58758402018-04-02 Technical note: TROG 15.01 SPARK trial multi‐institutional imaging dose measurement Legge, Kimberley Greer, Peter B. Keall, Paul J. Booth, Jeremy T. Arumugam, Sankar Moodie, Trevor Nguyen, Doan T. Martin, Jarad O'Connor, Daryl John Lehmann, Joerg J Appl Clin Med Phys Technical Notes PURPOSE: The Trans‐Tasman Radiation Oncology Group (TROG) 15.01 Stereotactic Prostate Adaptive Radiotherapy utilizing Kilovoltage intrafraction monitoring (SPARK) trial is a multicenter trial using Kilovoltage Intrafraction Monitoring (KIM) to monitor prostate position during the delivery of prostate radiation therapy. KIM increases the accuracy of prostate radiation therapy treatments and allows for hypofractionation. However, an additional imaging dose is delivered to the patient. A standardized procedure to determine the imaging dose per frame delivered using KIM was developed and applied at four radiation therapy centers on three different types of linear accelerator. METHODS: Dose per frame for kilovoltage imaging in fluoroscopy mode was measured in air at isocenter using an ion chamber. Beam quality and dose were determined for a Varian Clinac iX linear accelerator, a Varian Trilogy, four Varian Truebeams and one Elekta Synergy at four different radiation therapy centers. The imaging parameters used on the Varian machines were 125 kV, 80 mA, and 13 ms. The Elekta machine was measured at 120 kV, 80 mA, and 12 ms. Absorbed doses to the skin and the prostate for a typical SBRT prostate treatment length were estimated according to the IPEMB protocol. RESULTS: The average dose per kV frame to the skin was 0.24 ± 0.03 mGy. The average estimated absorbed dose to the prostate for all five treatment fractions across all machines measured was 39.9 ± 2.6 mGy for 1 Hz imaging, 199.7 ± 13.2 mGy for 5 Hz imaging and 439.3 ± 29.0 mGy for 11 Hz imaging. CONCLUSIONS: All machines measured agreed to within 20%. Additional dose to the prostate from using KIM is at most 1.3% of the prescribed dose of 36.25 Gy in five fractions delivered during the trial. John Wiley and Sons Inc. 2017-08-02 /pmc/articles/PMC5875840/ /pubmed/28766904 http://dx.doi.org/10.1002/acm2.12151 Text en © 2017 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, Inc. on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Technical Notes
Legge, Kimberley
Greer, Peter B.
Keall, Paul J.
Booth, Jeremy T.
Arumugam, Sankar
Moodie, Trevor
Nguyen, Doan T.
Martin, Jarad
O'Connor, Daryl John
Lehmann, Joerg
Technical note: TROG 15.01 SPARK trial multi‐institutional imaging dose measurement
title Technical note: TROG 15.01 SPARK trial multi‐institutional imaging dose measurement
title_full Technical note: TROG 15.01 SPARK trial multi‐institutional imaging dose measurement
title_fullStr Technical note: TROG 15.01 SPARK trial multi‐institutional imaging dose measurement
title_full_unstemmed Technical note: TROG 15.01 SPARK trial multi‐institutional imaging dose measurement
title_short Technical note: TROG 15.01 SPARK trial multi‐institutional imaging dose measurement
title_sort technical note: trog 15.01 spark trial multi‐institutional imaging dose measurement
topic Technical Notes
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5875840/
https://www.ncbi.nlm.nih.gov/pubmed/28766904
http://dx.doi.org/10.1002/acm2.12151
work_keys_str_mv AT leggekimberley technicalnotetrog1501sparktrialmultiinstitutionalimagingdosemeasurement
AT greerpeterb technicalnotetrog1501sparktrialmultiinstitutionalimagingdosemeasurement
AT keallpaulj technicalnotetrog1501sparktrialmultiinstitutionalimagingdosemeasurement
AT boothjeremyt technicalnotetrog1501sparktrialmultiinstitutionalimagingdosemeasurement
AT arumugamsankar technicalnotetrog1501sparktrialmultiinstitutionalimagingdosemeasurement
AT moodietrevor technicalnotetrog1501sparktrialmultiinstitutionalimagingdosemeasurement
AT nguyendoant technicalnotetrog1501sparktrialmultiinstitutionalimagingdosemeasurement
AT martinjarad technicalnotetrog1501sparktrialmultiinstitutionalimagingdosemeasurement
AT oconnordaryljohn technicalnotetrog1501sparktrialmultiinstitutionalimagingdosemeasurement
AT lehmannjoerg technicalnotetrog1501sparktrialmultiinstitutionalimagingdosemeasurement