Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors
Partial discharges (PD) measurement provides valuable information for the condition assessment of the insulation status of high-voltage (HV) electrical installations. During the last three decades, several PD sensors and measuring techniques have been developed to perform accurate diagnostics when P...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5877214/ https://www.ncbi.nlm.nih.gov/pubmed/29495601 http://dx.doi.org/10.3390/s18030720 |
_version_ | 1783310654510202880 |
---|---|
author | Álvarez Gómez, Fernando Albarracín-Sánchez, Ricardo Garnacho Vecino, Fernando Granizo Arrabé, Ricardo |
author_facet | Álvarez Gómez, Fernando Albarracín-Sánchez, Ricardo Garnacho Vecino, Fernando Granizo Arrabé, Ricardo |
author_sort | Álvarez Gómez, Fernando |
collection | PubMed |
description | Partial discharges (PD) measurement provides valuable information for the condition assessment of the insulation status of high-voltage (HV) electrical installations. During the last three decades, several PD sensors and measuring techniques have been developed to perform accurate diagnostics when PD measurements are carried out on-site and on-line. For utilities, the most attractive characteristics of on-line measurements are that once the sensors are installed in the grid, the electrical service is uninterrupted and that electrical systems are tested in real operating conditions. In medium-voltage (MV) and HV installations, one of the critical points where an insulation defect can occur is inside metal-clad switchgears (including the cable terminals connected to them). Thus, this kind of equipment is increasingly being monitored to carry out proper maintenance based on their condition. This paper presents a study concerning the application of different electromagnetic measuring techniques (compliant with IEC 62478 and IEC 60270 standards), together with the use of suitable sensors, which enable the evaluation of the insulation condition mainly in MV switchgears. The main scope is to give a general overview about appropriate types of electromagnetic measuring methods and sensors to be applied, while considering the level of detail and accuracy in the diagnosis and the particular fail-save requirements of the electrical installations where the switchgears are located. |
format | Online Article Text |
id | pubmed-5877214 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-58772142018-04-09 Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors Álvarez Gómez, Fernando Albarracín-Sánchez, Ricardo Garnacho Vecino, Fernando Granizo Arrabé, Ricardo Sensors (Basel) Article Partial discharges (PD) measurement provides valuable information for the condition assessment of the insulation status of high-voltage (HV) electrical installations. During the last three decades, several PD sensors and measuring techniques have been developed to perform accurate diagnostics when PD measurements are carried out on-site and on-line. For utilities, the most attractive characteristics of on-line measurements are that once the sensors are installed in the grid, the electrical service is uninterrupted and that electrical systems are tested in real operating conditions. In medium-voltage (MV) and HV installations, one of the critical points where an insulation defect can occur is inside metal-clad switchgears (including the cable terminals connected to them). Thus, this kind of equipment is increasingly being monitored to carry out proper maintenance based on their condition. This paper presents a study concerning the application of different electromagnetic measuring techniques (compliant with IEC 62478 and IEC 60270 standards), together with the use of suitable sensors, which enable the evaluation of the insulation condition mainly in MV switchgears. The main scope is to give a general overview about appropriate types of electromagnetic measuring methods and sensors to be applied, while considering the level of detail and accuracy in the diagnosis and the particular fail-save requirements of the electrical installations where the switchgears are located. MDPI 2018-02-28 /pmc/articles/PMC5877214/ /pubmed/29495601 http://dx.doi.org/10.3390/s18030720 Text en © 2018 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Álvarez Gómez, Fernando Albarracín-Sánchez, Ricardo Garnacho Vecino, Fernando Granizo Arrabé, Ricardo Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors |
title | Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors |
title_full | Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors |
title_fullStr | Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors |
title_full_unstemmed | Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors |
title_short | Diagnosis of Insulation Condition of MV Switchgears by Application of Different Partial Discharge Measuring Methods and Sensors |
title_sort | diagnosis of insulation condition of mv switchgears by application of different partial discharge measuring methods and sensors |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5877214/ https://www.ncbi.nlm.nih.gov/pubmed/29495601 http://dx.doi.org/10.3390/s18030720 |
work_keys_str_mv | AT alvarezgomezfernando diagnosisofinsulationconditionofmvswitchgearsbyapplicationofdifferentpartialdischargemeasuringmethodsandsensors AT albarracinsanchezricardo diagnosisofinsulationconditionofmvswitchgearsbyapplicationofdifferentpartialdischargemeasuringmethodsandsensors AT garnachovecinofernando diagnosisofinsulationconditionofmvswitchgearsbyapplicationofdifferentpartialdischargemeasuringmethodsandsensors AT granizoarrabericardo diagnosisofinsulationconditionofmvswitchgearsbyapplicationofdifferentpartialdischargemeasuringmethodsandsensors |