PURPOSE: The aim of this study was to describe different designs of semimonolithic crowns made of translucent and high-translucent zirconia materials and to evaluate the effect on fracture resistance and fracture mode. METHODS: One hundred crowns with different designs were produced and divided into...

Descripción completa

Detalles Bibliográficos
Autores principales: Bakitian, Fahad, Seweryniak, Przemek, Papia, Evaggelia, Larsson, Christel, Vult von Steyern, Per
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove Medical Press 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5878660/
https://www.ncbi.nlm.nih.gov/pubmed/29628778
http://dx.doi.org/10.2147/CCIDE.S157118
_version_ 1783310876765323264
author Bakitian, Fahad
Seweryniak, Przemek
Papia, Evaggelia
Larsson, Christel
Vult von Steyern, Per
author_facet Bakitian, Fahad
Seweryniak, Przemek
Papia, Evaggelia
Larsson, Christel
Vult von Steyern, Per
author_sort Bakitian, Fahad
collection PubMed
description PURPOSE: The aim of this study was to describe different designs of semimonolithic crowns made of translucent and high-translucent zirconia materials and to evaluate the effect on fracture resistance and fracture mode. METHODS: One hundred crowns with different designs were produced and divided into five groups (n=20): monolithic (M), partially veneered monolithic (semimonolithic) with 0.3 mm buccal veneer (SM0.3), semimonolithic with 0.5 mm buccal veneer (SM0.5), semimonolithic with 0.5 mm buccal veneer supported by wave design (SMW), and semimonolithic with 0.5 mm buccal veneer supported by occlusal cap design (SMC). Each group was divided into two subgroups (n=10) according to the materials used, translucent and high-translucent zirconia. All crowns underwent artificial aging before loading until fracture. Fracture mode analysis was performed. Fracture loads and fracture modes were analyzed using two-way ANOVA and Fisher’s exact probability tests (P≤0.05). RESULTS: SM0.3 design showed highest fracture loads with no significant difference compared to M and SMW designs (P>0.05). SM0.5 design showed lower fracture loads compared to SMW and SWC designs. Crowns made of translucent zirconia showed higher fracture loads compared to those made of high-translucent zirconia. M, SM0.3, and all but one of the SMC crowns showed complete fractures with significant differences in fracture mode compared to SMW and SM0.5 crowns with cohesive veneer fractures (P≤0.05). CONCLUSION: Translucent and high-translucent zirconia crowns might be used in combination with 0.3 mm microcoating porcelain layer with semimonolithic design to enhance the esthetic properties of restorations without significantly decreasing fracture resistance of the crowns. If 0.5 mm porcelain layer is needed for a semimonolithic crown, wave design or cap design might be used to increase fracture resistance. In both cases, fracture resistance gained is likely to be clinically sufficient as the registered fracture loads were high in relation to expected loads under clinical use.
format Online
Article
Text
id pubmed-5878660
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Dove Medical Press
record_format MEDLINE/PubMed
spelling pubmed-58786602018-04-06 Effect of different semimonolithic designs on fracture resistance and fracture mode of translucent and high-translucent zirconia crowns Bakitian, Fahad Seweryniak, Przemek Papia, Evaggelia Larsson, Christel Vult von Steyern, Per Clin Cosmet Investig Dent Original Research PURPOSE: The aim of this study was to describe different designs of semimonolithic crowns made of translucent and high-translucent zirconia materials and to evaluate the effect on fracture resistance and fracture mode. METHODS: One hundred crowns with different designs were produced and divided into five groups (n=20): monolithic (M), partially veneered monolithic (semimonolithic) with 0.3 mm buccal veneer (SM0.3), semimonolithic with 0.5 mm buccal veneer (SM0.5), semimonolithic with 0.5 mm buccal veneer supported by wave design (SMW), and semimonolithic with 0.5 mm buccal veneer supported by occlusal cap design (SMC). Each group was divided into two subgroups (n=10) according to the materials used, translucent and high-translucent zirconia. All crowns underwent artificial aging before loading until fracture. Fracture mode analysis was performed. Fracture loads and fracture modes were analyzed using two-way ANOVA and Fisher’s exact probability tests (P≤0.05). RESULTS: SM0.3 design showed highest fracture loads with no significant difference compared to M and SMW designs (P>0.05). SM0.5 design showed lower fracture loads compared to SMW and SWC designs. Crowns made of translucent zirconia showed higher fracture loads compared to those made of high-translucent zirconia. M, SM0.3, and all but one of the SMC crowns showed complete fractures with significant differences in fracture mode compared to SMW and SM0.5 crowns with cohesive veneer fractures (P≤0.05). CONCLUSION: Translucent and high-translucent zirconia crowns might be used in combination with 0.3 mm microcoating porcelain layer with semimonolithic design to enhance the esthetic properties of restorations without significantly decreasing fracture resistance of the crowns. If 0.5 mm porcelain layer is needed for a semimonolithic crown, wave design or cap design might be used to increase fracture resistance. In both cases, fracture resistance gained is likely to be clinically sufficient as the registered fracture loads were high in relation to expected loads under clinical use. Dove Medical Press 2018-03-28 /pmc/articles/PMC5878660/ /pubmed/29628778 http://dx.doi.org/10.2147/CCIDE.S157118 Text en © 2018 Bakitian et al. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.
spellingShingle Original Research
Bakitian, Fahad
Seweryniak, Przemek
Papia, Evaggelia
Larsson, Christel
Vult von Steyern, Per
Effect of different semimonolithic designs on fracture resistance and fracture mode of translucent and high-translucent zirconia crowns
title Effect of different semimonolithic designs on fracture resistance and fracture mode of translucent and high-translucent zirconia crowns
title_full Effect of different semimonolithic designs on fracture resistance and fracture mode of translucent and high-translucent zirconia crowns
title_fullStr Effect of different semimonolithic designs on fracture resistance and fracture mode of translucent and high-translucent zirconia crowns
title_full_unstemmed Effect of different semimonolithic designs on fracture resistance and fracture mode of translucent and high-translucent zirconia crowns
title_short Effect of different semimonolithic designs on fracture resistance and fracture mode of translucent and high-translucent zirconia crowns
title_sort effect of different semimonolithic designs on fracture resistance and fracture mode of translucent and high-translucent zirconia crowns
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5878660/
https://www.ncbi.nlm.nih.gov/pubmed/29628778
http://dx.doi.org/10.2147/CCIDE.S157118
work_keys_str_mv AT bakitianfahad effectofdifferentsemimonolithicdesignsonfractureresistanceandfracturemodeoftranslucentandhightranslucentzirconiacrowns
AT seweryniakprzemek effectofdifferentsemimonolithicdesignsonfractureresistanceandfracturemodeoftranslucentandhightranslucentzirconiacrowns
AT papiaevaggelia effectofdifferentsemimonolithicdesignsonfractureresistanceandfracturemodeoftranslucentandhightranslucentzirconiacrowns
AT larssonchristel effectofdifferentsemimonolithicdesignsonfractureresistanceandfracturemodeoftranslucentandhightranslucentzirconiacrowns
AT vultvonsteyernper effectofdifferentsemimonolithicdesignsonfractureresistanceandfracturemodeoftranslucentandhightranslucentzirconiacrowns