Cargando…

Comparison of Optic Nerve Sheath Diameter between both eyes: A Bedside Ultrasonography Approach

CONTEXT: Optic nerve sheath diameter (ONSD) has long been accepted as a reliable proxy of intracranial pressure especially in critical care and bedside settings. The present consensus is to measure ONSD in both eyes and take average value, which is cumbersome and a potential cause of discomfort to t...

Descripción completa

Detalles Bibliográficos
Autores principales: Yanamandra, Uday, Gupta, Amul, Bhattachar, Srinivasa A., Yanamandra, Sushma, Das, Subrat K., Patyal, Sagarika, Grewal, Rajan, Nair, Velu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5879856/
https://www.ncbi.nlm.nih.gov/pubmed/29657371
http://dx.doi.org/10.4103/ijccm.IJCCM_498_17
_version_ 1783311066405535744
author Yanamandra, Uday
Gupta, Amul
Bhattachar, Srinivasa A.
Yanamandra, Sushma
Das, Subrat K.
Patyal, Sagarika
Grewal, Rajan
Nair, Velu
author_facet Yanamandra, Uday
Gupta, Amul
Bhattachar, Srinivasa A.
Yanamandra, Sushma
Das, Subrat K.
Patyal, Sagarika
Grewal, Rajan
Nair, Velu
author_sort Yanamandra, Uday
collection PubMed
description CONTEXT: Optic nerve sheath diameter (ONSD) has long been accepted as a reliable proxy of intracranial pressure especially in critical care and bedside settings. The present consensus is to measure ONSD in both eyes and take average value, which is cumbersome and a potential cause of discomfort to the patient. AIM: We aim to compare the values of ONSD of the right and left eye in a random sample as measured by bedside ocular ultrasonography (USG) in Indian adults. SETTINGS AND DESIGN: This was a prospective study conducted from September 2012 to March 2013 in the Department of Internal Medicine of a tertiary care hospital situated at moderate high altitude (11,500 ft) in India. MATERIALS AND METHODS: Patients admitted with high altitude pulmonary edema (HAPE) were recruited by convenience sampling. The ONSD of both eyes were measured 3 mm behind the globe using a 7.5 MHz linear probe on the closed eyelids of supine subjects. STATISTICAL ANALYSIS: Analysis was done using SPSS 17.0. RESULTS: A total of 47 patients of HAPE were recruited to the study with daily ONSD recording of both eyes during the admission period. The mean ONSD of the left eye was 4.60 (standard deviation [SD] = 0.71) whereas the mean ONSD of right eye 4.59 (SD = 0.72). The ONSD of the right eye and left eye was strongly correlated (correlation coefficient = 0.98 with P < 0.0001). The mean difference in the ONSD of both eyes (right–left) was −0.0044 (SD = 0.11) which was not statistically significant (P = 0.533). CONCLUSION: Our results suggest that the difference in ONSD of both eyes is not statistically significant in disease or health. This study also suggests that the ONSD of either eye can be predicted by the other eye recordings. Based on these findings, it can be suggested that during ocular USG for routine bedside/research purposes it is sufficient to measure ONSD of any of the one eye to save time and avoid discomfort to the patient.
format Online
Article
Text
id pubmed-5879856
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-58798562018-04-13 Comparison of Optic Nerve Sheath Diameter between both eyes: A Bedside Ultrasonography Approach Yanamandra, Uday Gupta, Amul Bhattachar, Srinivasa A. Yanamandra, Sushma Das, Subrat K. Patyal, Sagarika Grewal, Rajan Nair, Velu Indian J Crit Care Med Research Article CONTEXT: Optic nerve sheath diameter (ONSD) has long been accepted as a reliable proxy of intracranial pressure especially in critical care and bedside settings. The present consensus is to measure ONSD in both eyes and take average value, which is cumbersome and a potential cause of discomfort to the patient. AIM: We aim to compare the values of ONSD of the right and left eye in a random sample as measured by bedside ocular ultrasonography (USG) in Indian adults. SETTINGS AND DESIGN: This was a prospective study conducted from September 2012 to March 2013 in the Department of Internal Medicine of a tertiary care hospital situated at moderate high altitude (11,500 ft) in India. MATERIALS AND METHODS: Patients admitted with high altitude pulmonary edema (HAPE) were recruited by convenience sampling. The ONSD of both eyes were measured 3 mm behind the globe using a 7.5 MHz linear probe on the closed eyelids of supine subjects. STATISTICAL ANALYSIS: Analysis was done using SPSS 17.0. RESULTS: A total of 47 patients of HAPE were recruited to the study with daily ONSD recording of both eyes during the admission period. The mean ONSD of the left eye was 4.60 (standard deviation [SD] = 0.71) whereas the mean ONSD of right eye 4.59 (SD = 0.72). The ONSD of the right eye and left eye was strongly correlated (correlation coefficient = 0.98 with P < 0.0001). The mean difference in the ONSD of both eyes (right–left) was −0.0044 (SD = 0.11) which was not statistically significant (P = 0.533). CONCLUSION: Our results suggest that the difference in ONSD of both eyes is not statistically significant in disease or health. This study also suggests that the ONSD of either eye can be predicted by the other eye recordings. Based on these findings, it can be suggested that during ocular USG for routine bedside/research purposes it is sufficient to measure ONSD of any of the one eye to save time and avoid discomfort to the patient. Medknow Publications & Media Pvt Ltd 2018-03 /pmc/articles/PMC5879856/ /pubmed/29657371 http://dx.doi.org/10.4103/ijccm.IJCCM_498_17 Text en Copyright: © 2018 Indian Journal of Critical Care Medicine http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Research Article
Yanamandra, Uday
Gupta, Amul
Bhattachar, Srinivasa A.
Yanamandra, Sushma
Das, Subrat K.
Patyal, Sagarika
Grewal, Rajan
Nair, Velu
Comparison of Optic Nerve Sheath Diameter between both eyes: A Bedside Ultrasonography Approach
title Comparison of Optic Nerve Sheath Diameter between both eyes: A Bedside Ultrasonography Approach
title_full Comparison of Optic Nerve Sheath Diameter between both eyes: A Bedside Ultrasonography Approach
title_fullStr Comparison of Optic Nerve Sheath Diameter between both eyes: A Bedside Ultrasonography Approach
title_full_unstemmed Comparison of Optic Nerve Sheath Diameter between both eyes: A Bedside Ultrasonography Approach
title_short Comparison of Optic Nerve Sheath Diameter between both eyes: A Bedside Ultrasonography Approach
title_sort comparison of optic nerve sheath diameter between both eyes: a bedside ultrasonography approach
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5879856/
https://www.ncbi.nlm.nih.gov/pubmed/29657371
http://dx.doi.org/10.4103/ijccm.IJCCM_498_17
work_keys_str_mv AT yanamandrauday comparisonofopticnervesheathdiameterbetweenbotheyesabedsideultrasonographyapproach
AT guptaamul comparisonofopticnervesheathdiameterbetweenbotheyesabedsideultrasonographyapproach
AT bhattacharsrinivasaa comparisonofopticnervesheathdiameterbetweenbotheyesabedsideultrasonographyapproach
AT yanamandrasushma comparisonofopticnervesheathdiameterbetweenbotheyesabedsideultrasonographyapproach
AT dassubratk comparisonofopticnervesheathdiameterbetweenbotheyesabedsideultrasonographyapproach
AT patyalsagarika comparisonofopticnervesheathdiameterbetweenbotheyesabedsideultrasonographyapproach
AT grewalrajan comparisonofopticnervesheathdiameterbetweenbotheyesabedsideultrasonographyapproach
AT nairvelu comparisonofopticnervesheathdiameterbetweenbotheyesabedsideultrasonographyapproach