Cargando…

The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs

BACKGROUND: Several radiological methods for measuring the anteversion of the acetabular component after total hip arthroplasty (THA) exist, and no single standardized method has been established. We evaluated the reliability and accuracy of six widely utilized methods (Liaw et al., Lewinnek et al.,...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Yang Soo, Shin, Won Chul, Lee, Sang Min, Kwak, Sang Ho, Bae, Jung Yun, Suh, Kuen Tak
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5879940/
https://www.ncbi.nlm.nih.gov/pubmed/29609639
http://dx.doi.org/10.1186/s13018-018-0767-4
_version_ 1783311086524563456
author Park, Yang Soo
Shin, Won Chul
Lee, Sang Min
Kwak, Sang Ho
Bae, Jung Yun
Suh, Kuen Tak
author_facet Park, Yang Soo
Shin, Won Chul
Lee, Sang Min
Kwak, Sang Ho
Bae, Jung Yun
Suh, Kuen Tak
author_sort Park, Yang Soo
collection PubMed
description BACKGROUND: Several radiological methods for measuring the anteversion of the acetabular component after total hip arthroplasty (THA) exist, and no single standardized method has been established. We evaluated the reliability and accuracy of six widely utilized methods (Liaw et al., Lewinnek et al., Widmer, Hassan et al., Ackland et al., and Woo and Morrey) for measuring anteversion on plain radiographs, using a reference standard in the same definition obtained from the PolyWare programme. METHODS: We reviewed 71 patients who underwent primary unilateral THA. The anteversion of the acetabular component was measured on pelvis AP radiographs using five different methods (Liaw et al., Lewinnek et al., Widmer, Hassan et al., and Ackland et al.) and on cross-table lateral radiographs using the method of Woo and Morrey. The values obtained using the PolyWare programme, which determines the anteversion of the acetabular component by edge detection, were regarded as the reference standard. RESULTS: Intra- and inter-observer reliabilities were excellent for all methods using plain radiographs, including the PolyWare programme. The method of Liaw et al. obtained values similar to those obtained using the PolyWare programme and was thus considered accurate (P = 0.447). However, values obtained using the other five methods significantly differed from those obtained using the PolyWare programme and were thus considered less accurate (P < 0.001, P < 0.001, P < 0.001, P = 0.007, and P < 0.001, respectively). CONCLUSION: The method of Liaw et al. is more accurate than other methods using plain radiographs for the measurement of the anteversion of the acetabular component after THA, with reference to the anteversion obtained from the PolyWare programme.
format Online
Article
Text
id pubmed-5879940
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-58799402018-04-04 The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs Park, Yang Soo Shin, Won Chul Lee, Sang Min Kwak, Sang Ho Bae, Jung Yun Suh, Kuen Tak J Orthop Surg Res Research Article BACKGROUND: Several radiological methods for measuring the anteversion of the acetabular component after total hip arthroplasty (THA) exist, and no single standardized method has been established. We evaluated the reliability and accuracy of six widely utilized methods (Liaw et al., Lewinnek et al., Widmer, Hassan et al., Ackland et al., and Woo and Morrey) for measuring anteversion on plain radiographs, using a reference standard in the same definition obtained from the PolyWare programme. METHODS: We reviewed 71 patients who underwent primary unilateral THA. The anteversion of the acetabular component was measured on pelvis AP radiographs using five different methods (Liaw et al., Lewinnek et al., Widmer, Hassan et al., and Ackland et al.) and on cross-table lateral radiographs using the method of Woo and Morrey. The values obtained using the PolyWare programme, which determines the anteversion of the acetabular component by edge detection, were regarded as the reference standard. RESULTS: Intra- and inter-observer reliabilities were excellent for all methods using plain radiographs, including the PolyWare programme. The method of Liaw et al. obtained values similar to those obtained using the PolyWare programme and was thus considered accurate (P = 0.447). However, values obtained using the other five methods significantly differed from those obtained using the PolyWare programme and were thus considered less accurate (P < 0.001, P < 0.001, P < 0.001, P = 0.007, and P < 0.001, respectively). CONCLUSION: The method of Liaw et al. is more accurate than other methods using plain radiographs for the measurement of the anteversion of the acetabular component after THA, with reference to the anteversion obtained from the PolyWare programme. BioMed Central 2018-04-02 /pmc/articles/PMC5879940/ /pubmed/29609639 http://dx.doi.org/10.1186/s13018-018-0767-4 Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.
spellingShingle Research Article
Park, Yang Soo
Shin, Won Chul
Lee, Sang Min
Kwak, Sang Ho
Bae, Jung Yun
Suh, Kuen Tak
The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs
title The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs
title_full The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs
title_fullStr The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs
title_full_unstemmed The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs
title_short The best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs
title_sort best method for evaluating anteversion of the acetabular component after total hip arthroplasty on plain radiographs
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5879940/
https://www.ncbi.nlm.nih.gov/pubmed/29609639
http://dx.doi.org/10.1186/s13018-018-0767-4
work_keys_str_mv AT parkyangsoo thebestmethodforevaluatinganteversionoftheacetabularcomponentaftertotalhiparthroplastyonplainradiographs
AT shinwonchul thebestmethodforevaluatinganteversionoftheacetabularcomponentaftertotalhiparthroplastyonplainradiographs
AT leesangmin thebestmethodforevaluatinganteversionoftheacetabularcomponentaftertotalhiparthroplastyonplainradiographs
AT kwaksangho thebestmethodforevaluatinganteversionoftheacetabularcomponentaftertotalhiparthroplastyonplainradiographs
AT baejungyun thebestmethodforevaluatinganteversionoftheacetabularcomponentaftertotalhiparthroplastyonplainradiographs
AT suhkuentak thebestmethodforevaluatinganteversionoftheacetabularcomponentaftertotalhiparthroplastyonplainradiographs
AT parkyangsoo bestmethodforevaluatinganteversionoftheacetabularcomponentaftertotalhiparthroplastyonplainradiographs
AT shinwonchul bestmethodforevaluatinganteversionoftheacetabularcomponentaftertotalhiparthroplastyonplainradiographs
AT leesangmin bestmethodforevaluatinganteversionoftheacetabularcomponentaftertotalhiparthroplastyonplainradiographs
AT kwaksangho bestmethodforevaluatinganteversionoftheacetabularcomponentaftertotalhiparthroplastyonplainradiographs
AT baejungyun bestmethodforevaluatinganteversionoftheacetabularcomponentaftertotalhiparthroplastyonplainradiographs
AT suhkuentak bestmethodforevaluatinganteversionoftheacetabularcomponentaftertotalhiparthroplastyonplainradiographs