Cargando…
Comparison of simulated keratometric changes following wavefront-guided and wavefront-optimized myopic laser-assisted in situ keratomileusis
PURPOSE: The aim of the study was to determine and compare the relationship between change in simulated keratometry (K) and degree of refractive correction in wavefront-guided (WFG) and wavefront-optimized (WFO) myopic laser-assisted in situ keratomileusis (LASIK). METHODS: A total of 51 patients we...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Dove Medical Press
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5880184/ https://www.ncbi.nlm.nih.gov/pubmed/29636597 http://dx.doi.org/10.2147/OPTH.S161387 |
_version_ | 1783311120447045632 |
---|---|
author | Lee, Wen-Shin Manche, Edward E |
author_facet | Lee, Wen-Shin Manche, Edward E |
author_sort | Lee, Wen-Shin |
collection | PubMed |
description | PURPOSE: The aim of the study was to determine and compare the relationship between change in simulated keratometry (K) and degree of refractive correction in wavefront-guided (WFG) and wavefront-optimized (WFO) myopic laser-assisted in situ keratomileusis (LASIK). METHODS: A total of 51 patients were prospectively randomized to WFG LASIK in one eye and WFO LASIK in the contralateral eye at the Byers Eye Institute, Stanford University. Changes in simulated K and refractive error were determined at 1 year post-operatively. Linear regression was employed to calculate the slope of change in simulated K (ΔK) for change in refractive error (ΔSE). The mean ratio (ΔK/ΔSE) was also calculated. RESULTS: The ratio of ΔK to ΔSE was larger for WFG LASIK compared to WFO LASIK when comparing the slope (ΔK/ΔSE) as determined by linear regression (0.85 vs 0.83, p = 0.04). Upon comparing the mean ratio (ΔK/ΔSE), subgroup analysis revealed that ΔK/ΔSE was larger for WFG LASIK for refractive corrections of >3.00 D and >4.00 D (0.89 vs 0.83; p = 0.0323 and 0.88 vs 0.83; p = 0.0466, respectively). Both linear regression and direct comparison of the mean ratio (ΔK/ΔSE) for refractive corrections <4.00 D and >4.00 D revealed no difference in ΔK/ΔSE between smaller and larger refractive corrections. CONCLUSION: WFO LASIK requires a smaller amount of corneal flattening compared to WFG LASIK for a given degree of refractive correction. For both, there was no significant difference in change in corneal curvature for a given degree of refractive error between smaller and larger corrections. |
format | Online Article Text |
id | pubmed-5880184 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Dove Medical Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-58801842018-04-10 Comparison of simulated keratometric changes following wavefront-guided and wavefront-optimized myopic laser-assisted in situ keratomileusis Lee, Wen-Shin Manche, Edward E Clin Ophthalmol Original Research PURPOSE: The aim of the study was to determine and compare the relationship between change in simulated keratometry (K) and degree of refractive correction in wavefront-guided (WFG) and wavefront-optimized (WFO) myopic laser-assisted in situ keratomileusis (LASIK). METHODS: A total of 51 patients were prospectively randomized to WFG LASIK in one eye and WFO LASIK in the contralateral eye at the Byers Eye Institute, Stanford University. Changes in simulated K and refractive error were determined at 1 year post-operatively. Linear regression was employed to calculate the slope of change in simulated K (ΔK) for change in refractive error (ΔSE). The mean ratio (ΔK/ΔSE) was also calculated. RESULTS: The ratio of ΔK to ΔSE was larger for WFG LASIK compared to WFO LASIK when comparing the slope (ΔK/ΔSE) as determined by linear regression (0.85 vs 0.83, p = 0.04). Upon comparing the mean ratio (ΔK/ΔSE), subgroup analysis revealed that ΔK/ΔSE was larger for WFG LASIK for refractive corrections of >3.00 D and >4.00 D (0.89 vs 0.83; p = 0.0323 and 0.88 vs 0.83; p = 0.0466, respectively). Both linear regression and direct comparison of the mean ratio (ΔK/ΔSE) for refractive corrections <4.00 D and >4.00 D revealed no difference in ΔK/ΔSE between smaller and larger refractive corrections. CONCLUSION: WFO LASIK requires a smaller amount of corneal flattening compared to WFG LASIK for a given degree of refractive correction. For both, there was no significant difference in change in corneal curvature for a given degree of refractive error between smaller and larger corrections. Dove Medical Press 2018-03-29 /pmc/articles/PMC5880184/ /pubmed/29636597 http://dx.doi.org/10.2147/OPTH.S161387 Text en © 2018 Lee and Manche. This work is published and licensed by Dove Medical Press Limited The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. |
spellingShingle | Original Research Lee, Wen-Shin Manche, Edward E Comparison of simulated keratometric changes following wavefront-guided and wavefront-optimized myopic laser-assisted in situ keratomileusis |
title | Comparison of simulated keratometric changes following wavefront-guided and wavefront-optimized myopic laser-assisted in situ keratomileusis |
title_full | Comparison of simulated keratometric changes following wavefront-guided and wavefront-optimized myopic laser-assisted in situ keratomileusis |
title_fullStr | Comparison of simulated keratometric changes following wavefront-guided and wavefront-optimized myopic laser-assisted in situ keratomileusis |
title_full_unstemmed | Comparison of simulated keratometric changes following wavefront-guided and wavefront-optimized myopic laser-assisted in situ keratomileusis |
title_short | Comparison of simulated keratometric changes following wavefront-guided and wavefront-optimized myopic laser-assisted in situ keratomileusis |
title_sort | comparison of simulated keratometric changes following wavefront-guided and wavefront-optimized myopic laser-assisted in situ keratomileusis |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5880184/ https://www.ncbi.nlm.nih.gov/pubmed/29636597 http://dx.doi.org/10.2147/OPTH.S161387 |
work_keys_str_mv | AT leewenshin comparisonofsimulatedkeratometricchangesfollowingwavefrontguidedandwavefrontoptimizedmyopiclaserassistedinsitukeratomileusis AT mancheedwarde comparisonofsimulatedkeratometricchangesfollowingwavefrontguidedandwavefrontoptimizedmyopiclaserassistedinsitukeratomileusis |