PURPOSE: Annotation of meaningful landmark ground truth on DCE-MRI is difficult and laborious. Motion correction methods applied to DCE-MRI of the liver are thus mostly evaluated using qualitative or indirect measures. We propose a novel landmark annotation scheme that facilitates the generation of...

Descripción completa

Detalles Bibliográficos
Autores principales: Strehlow, Jan, Spahr, Nadine, Rühaak, Jan, Laue, Hendrik, Abolmaali, Nasreddin, Preusser, Tobias, Schenk, Andrea
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5880871/
https://www.ncbi.nlm.nih.gov/pubmed/29473128
http://dx.doi.org/10.1007/s11548-018-1710-1
Descripción
Sumario:PURPOSE: Annotation of meaningful landmark ground truth on DCE-MRI is difficult and laborious. Motion correction methods applied to DCE-MRI of the liver are thus mostly evaluated using qualitative or indirect measures. We propose a novel landmark annotation scheme that facilitates the generation of landmark ground truth on larger clinical datasets. METHODS: In our annotation scheme, landmarks are equally distributed over all time points of all available dataset cases and annotated by multiple observers on a per-pair basis. The scheme is used to annotate 26 DCE-MRI of the liver. A subset of the ground truth is used to optimize parameters of a deformable motion correction. Several variants of the motion correction are evaluated on the remaining cases with respect to distances of corresponding landmarks after registration, deformation field properties, and qualitative measures. RESULTS: A landmark ground truth on 26 cases could be generated in under 12 h per observer with a mean inter-observer distance below the mean voxel diagonal. Furthermore, the landmarks are spatially well distributed within the liver. Parameter optimization significantly improves the performance of the motion correction, and landmark distance after registration is 2 mm. Qualitative evaluation of the motion correction reflects the quantitative results. CONCLUSIONS: The annotation scheme makes a landmark-based evaluation of motion corrections for hepatic DCE-MRI practically feasible for larger clinical datasets. The comparably large number of cases enables both optimization and evaluation of motion correction methods. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s11548-018-1710-1) contains supplementary material, which is available to authorized users.