Landmark-based evaluation of a deformable motion correction for DCE-MRI of the liver

PURPOSE: Annotation of meaningful landmark ground truth on DCE-MRI is difficult and laborious. Motion correction methods applied to DCE-MRI of the liver are thus mostly evaluated using qualitative or indirect measures. We propose a novel landmark annotation scheme that facilitates the generation of...

Descripción completa

Detalles Bibliográficos
Autores principales: Strehlow, Jan, Spahr, Nadine, Rühaak, Jan, Laue, Hendrik, Abolmaali, Nasreddin, Preusser, Tobias, Schenk, Andrea
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5880871/
https://www.ncbi.nlm.nih.gov/pubmed/29473128
http://dx.doi.org/10.1007/s11548-018-1710-1
_version_ 1783311214733950976
author Strehlow, Jan
Spahr, Nadine
Rühaak, Jan
Laue, Hendrik
Abolmaali, Nasreddin
Preusser, Tobias
Schenk, Andrea
author_facet Strehlow, Jan
Spahr, Nadine
Rühaak, Jan
Laue, Hendrik
Abolmaali, Nasreddin
Preusser, Tobias
Schenk, Andrea
author_sort Strehlow, Jan
collection PubMed
description PURPOSE: Annotation of meaningful landmark ground truth on DCE-MRI is difficult and laborious. Motion correction methods applied to DCE-MRI of the liver are thus mostly evaluated using qualitative or indirect measures. We propose a novel landmark annotation scheme that facilitates the generation of landmark ground truth on larger clinical datasets. METHODS: In our annotation scheme, landmarks are equally distributed over all time points of all available dataset cases and annotated by multiple observers on a per-pair basis. The scheme is used to annotate 26 DCE-MRI of the liver. A subset of the ground truth is used to optimize parameters of a deformable motion correction. Several variants of the motion correction are evaluated on the remaining cases with respect to distances of corresponding landmarks after registration, deformation field properties, and qualitative measures. RESULTS: A landmark ground truth on 26 cases could be generated in under 12 h per observer with a mean inter-observer distance below the mean voxel diagonal. Furthermore, the landmarks are spatially well distributed within the liver. Parameter optimization significantly improves the performance of the motion correction, and landmark distance after registration is 2 mm. Qualitative evaluation of the motion correction reflects the quantitative results. CONCLUSIONS: The annotation scheme makes a landmark-based evaluation of motion corrections for hepatic DCE-MRI practically feasible for larger clinical datasets. The comparably large number of cases enables both optimization and evaluation of motion correction methods. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s11548-018-1710-1) contains supplementary material, which is available to authorized users.
format Online
Article
Text
id pubmed-5880871
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-58808712018-04-05 Landmark-based evaluation of a deformable motion correction for DCE-MRI of the liver Strehlow, Jan Spahr, Nadine Rühaak, Jan Laue, Hendrik Abolmaali, Nasreddin Preusser, Tobias Schenk, Andrea Int J Comput Assist Radiol Surg Original Article PURPOSE: Annotation of meaningful landmark ground truth on DCE-MRI is difficult and laborious. Motion correction methods applied to DCE-MRI of the liver are thus mostly evaluated using qualitative or indirect measures. We propose a novel landmark annotation scheme that facilitates the generation of landmark ground truth on larger clinical datasets. METHODS: In our annotation scheme, landmarks are equally distributed over all time points of all available dataset cases and annotated by multiple observers on a per-pair basis. The scheme is used to annotate 26 DCE-MRI of the liver. A subset of the ground truth is used to optimize parameters of a deformable motion correction. Several variants of the motion correction are evaluated on the remaining cases with respect to distances of corresponding landmarks after registration, deformation field properties, and qualitative measures. RESULTS: A landmark ground truth on 26 cases could be generated in under 12 h per observer with a mean inter-observer distance below the mean voxel diagonal. Furthermore, the landmarks are spatially well distributed within the liver. Parameter optimization significantly improves the performance of the motion correction, and landmark distance after registration is 2 mm. Qualitative evaluation of the motion correction reflects the quantitative results. CONCLUSIONS: The annotation scheme makes a landmark-based evaluation of motion corrections for hepatic DCE-MRI practically feasible for larger clinical datasets. The comparably large number of cases enables both optimization and evaluation of motion correction methods. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s11548-018-1710-1) contains supplementary material, which is available to authorized users. Springer International Publishing 2018-02-23 2018 /pmc/articles/PMC5880871/ /pubmed/29473128 http://dx.doi.org/10.1007/s11548-018-1710-1 Text en © The Author(s) 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Original Article
Strehlow, Jan
Spahr, Nadine
Rühaak, Jan
Laue, Hendrik
Abolmaali, Nasreddin
Preusser, Tobias
Schenk, Andrea
Landmark-based evaluation of a deformable motion correction for DCE-MRI of the liver
title Landmark-based evaluation of a deformable motion correction for DCE-MRI of the liver
title_full Landmark-based evaluation of a deformable motion correction for DCE-MRI of the liver
title_fullStr Landmark-based evaluation of a deformable motion correction for DCE-MRI of the liver
title_full_unstemmed Landmark-based evaluation of a deformable motion correction for DCE-MRI of the liver
title_short Landmark-based evaluation of a deformable motion correction for DCE-MRI of the liver
title_sort landmark-based evaluation of a deformable motion correction for dce-mri of the liver
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5880871/
https://www.ncbi.nlm.nih.gov/pubmed/29473128
http://dx.doi.org/10.1007/s11548-018-1710-1
work_keys_str_mv AT strehlowjan landmarkbasedevaluationofadeformablemotioncorrectionfordcemrioftheliver
AT spahrnadine landmarkbasedevaluationofadeformablemotioncorrectionfordcemrioftheliver
AT ruhaakjan landmarkbasedevaluationofadeformablemotioncorrectionfordcemrioftheliver
AT lauehendrik landmarkbasedevaluationofadeformablemotioncorrectionfordcemrioftheliver
AT abolmaalinasreddin landmarkbasedevaluationofadeformablemotioncorrectionfordcemrioftheliver
AT preussertobias landmarkbasedevaluationofadeformablemotioncorrectionfordcemrioftheliver
AT schenkandrea landmarkbasedevaluationofadeformablemotioncorrectionfordcemrioftheliver