Cargando…

Evaluation of performance of Streamlined Liner of the Pharynx Airway™, Laryngeal Mask Airway-ProSeal and endotracheal tube in prone position: A prospective, randomised study

BACKGROUND AND AIMS: Airway used in prone position should be efficacious and safe. The Streamlined Liner of the Pharynx Airway (SLIPA™) and Laryngeal Mask Airway-ProSeal (PLMA) provide better airway seal and protection against aspiration. We planned to evaluate the performance of SLIPA™, PLMA and en...

Descripción completa

Detalles Bibliográficos
Autores principales: Hegde, Harihar Vishwanath, Bandi, Joshiraj, Mudakanagoudar, Mahantesh S, Honnannavar, Kiran A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5881318/
https://www.ncbi.nlm.nih.gov/pubmed/29643550
http://dx.doi.org/10.4103/ija.IJA_691_17
_version_ 1783311297745518592
author Hegde, Harihar Vishwanath
Bandi, Joshiraj
Mudakanagoudar, Mahantesh S
Honnannavar, Kiran A
author_facet Hegde, Harihar Vishwanath
Bandi, Joshiraj
Mudakanagoudar, Mahantesh S
Honnannavar, Kiran A
author_sort Hegde, Harihar Vishwanath
collection PubMed
description BACKGROUND AND AIMS: Airway used in prone position should be efficacious and safe. The Streamlined Liner of the Pharynx Airway (SLIPA™) and Laryngeal Mask Airway-ProSeal (PLMA) provide better airway seal and protection against aspiration. We planned to evaluate the performance of SLIPA™, PLMA and endotracheal tube (ETT) in prone position. METHODS: 114 adult patients undergoing elective surgery in prone position under general anaesthesia were randomised into Group-T (ETT), Group-S (SLIPA™) and Group-P (PLMA). Airways were inserted in supine position and patients turned prone subsequently. Airway characteristics, ventilatory parameters and complications were noted. One-way analysis of variance, Mann–Whitney U-test and Chi-square or Fisher's exact test were used. RESULTS: Tidal volumes, peak airway pressure and compliance were comparable at all times. Leak pressure was significantly higher (P < 0.001) in Group-T (mean leak pressure = 40 cmH(2)O) when compared to Group-S and Group-P at all the times of recording, and there was no significant difference between Group-S and Group-P. The number of patients requiring airway/neck manipulation in prone position was significantly higher (P < 0.001) in Group-S (19 [55.9%]) when the three groups were compared (none in Group-T) and in comparison with Group-P (5 [14.7%], P < 0.001). On airway removal, the incidence of complications and airway reaction was significantly higher in Group-T. Group-S had a significantly higher incidence of dysphagia at 2 h postoperatively. CONCLUSION: ETT was most efficacious. SLIPA™ and PLMA were efficacious, safe and less stimulating to the airway during removal. More patients required SLIPA™ airway/neck manipulation.
format Online
Article
Text
id pubmed-5881318
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-58813182018-04-11 Evaluation of performance of Streamlined Liner of the Pharynx Airway™, Laryngeal Mask Airway-ProSeal and endotracheal tube in prone position: A prospective, randomised study Hegde, Harihar Vishwanath Bandi, Joshiraj Mudakanagoudar, Mahantesh S Honnannavar, Kiran A Indian J Anaesth Original Article BACKGROUND AND AIMS: Airway used in prone position should be efficacious and safe. The Streamlined Liner of the Pharynx Airway (SLIPA™) and Laryngeal Mask Airway-ProSeal (PLMA) provide better airway seal and protection against aspiration. We planned to evaluate the performance of SLIPA™, PLMA and endotracheal tube (ETT) in prone position. METHODS: 114 adult patients undergoing elective surgery in prone position under general anaesthesia were randomised into Group-T (ETT), Group-S (SLIPA™) and Group-P (PLMA). Airways were inserted in supine position and patients turned prone subsequently. Airway characteristics, ventilatory parameters and complications were noted. One-way analysis of variance, Mann–Whitney U-test and Chi-square or Fisher's exact test were used. RESULTS: Tidal volumes, peak airway pressure and compliance were comparable at all times. Leak pressure was significantly higher (P < 0.001) in Group-T (mean leak pressure = 40 cmH(2)O) when compared to Group-S and Group-P at all the times of recording, and there was no significant difference between Group-S and Group-P. The number of patients requiring airway/neck manipulation in prone position was significantly higher (P < 0.001) in Group-S (19 [55.9%]) when the three groups were compared (none in Group-T) and in comparison with Group-P (5 [14.7%], P < 0.001). On airway removal, the incidence of complications and airway reaction was significantly higher in Group-T. Group-S had a significantly higher incidence of dysphagia at 2 h postoperatively. CONCLUSION: ETT was most efficacious. SLIPA™ and PLMA were efficacious, safe and less stimulating to the airway during removal. More patients required SLIPA™ airway/neck manipulation. Medknow Publications & Media Pvt Ltd 2018-03 /pmc/articles/PMC5881318/ /pubmed/29643550 http://dx.doi.org/10.4103/ija.IJA_691_17 Text en Copyright: © 2018 Indian Journal of Anaesthesia http://creativecommons.org/licenses/by-nc-sa/3.0 This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 3.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as the author is credited and the new creations are licensed under the identical terms.
spellingShingle Original Article
Hegde, Harihar Vishwanath
Bandi, Joshiraj
Mudakanagoudar, Mahantesh S
Honnannavar, Kiran A
Evaluation of performance of Streamlined Liner of the Pharynx Airway™, Laryngeal Mask Airway-ProSeal and endotracheal tube in prone position: A prospective, randomised study
title Evaluation of performance of Streamlined Liner of the Pharynx Airway™, Laryngeal Mask Airway-ProSeal and endotracheal tube in prone position: A prospective, randomised study
title_full Evaluation of performance of Streamlined Liner of the Pharynx Airway™, Laryngeal Mask Airway-ProSeal and endotracheal tube in prone position: A prospective, randomised study
title_fullStr Evaluation of performance of Streamlined Liner of the Pharynx Airway™, Laryngeal Mask Airway-ProSeal and endotracheal tube in prone position: A prospective, randomised study
title_full_unstemmed Evaluation of performance of Streamlined Liner of the Pharynx Airway™, Laryngeal Mask Airway-ProSeal and endotracheal tube in prone position: A prospective, randomised study
title_short Evaluation of performance of Streamlined Liner of the Pharynx Airway™, Laryngeal Mask Airway-ProSeal and endotracheal tube in prone position: A prospective, randomised study
title_sort evaluation of performance of streamlined liner of the pharynx airway™, laryngeal mask airway-proseal and endotracheal tube in prone position: a prospective, randomised study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5881318/
https://www.ncbi.nlm.nih.gov/pubmed/29643550
http://dx.doi.org/10.4103/ija.IJA_691_17
work_keys_str_mv AT hegdehariharvishwanath evaluationofperformanceofstreamlinedlinerofthepharynxairwaylaryngealmaskairwayprosealandendotrachealtubeinpronepositionaprospectiverandomisedstudy
AT bandijoshiraj evaluationofperformanceofstreamlinedlinerofthepharynxairwaylaryngealmaskairwayprosealandendotrachealtubeinpronepositionaprospectiverandomisedstudy
AT mudakanagoudarmahanteshs evaluationofperformanceofstreamlinedlinerofthepharynxairwaylaryngealmaskairwayprosealandendotrachealtubeinpronepositionaprospectiverandomisedstudy
AT honnannavarkirana evaluationofperformanceofstreamlinedlinerofthepharynxairwaylaryngealmaskairwayprosealandendotrachealtubeinpronepositionaprospectiverandomisedstudy