Dynamic spinal compression revealed by computed tomography myelography in overshunting-associated myelopathy: A case report

RATIONALE: OSAM is a rare ventriculoperitoneal (VP) shunt complication where cervical spinal cord compression by epidural venous plexus engorgement is caused by cerebrospinal fluid (CSF) overdrainage. Symmetrically indented deformity of the upper cervical spinal cord and surrounding epidural venous...

Descripción completa

Detalles Bibliográficos
Autores principales: Amano, Eiichiro, Ozaki, Kokoro, Egawa, Satoru, Suzuki, Motohiro, Hirai, Takashi, Ishibashi, Satoru, Ohkubo, Takuya, Yoshii, Toshitaka, Okawa, Atsushi, Yokota, Takanori
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5882412/
https://www.ncbi.nlm.nih.gov/pubmed/29517672
http://dx.doi.org/10.1097/MD.0000000000010082
_version_ 1783311463909163008
author Amano, Eiichiro
Ozaki, Kokoro
Egawa, Satoru
Suzuki, Motohiro
Hirai, Takashi
Ishibashi, Satoru
Ohkubo, Takuya
Yoshii, Toshitaka
Okawa, Atsushi
Yokota, Takanori
author_facet Amano, Eiichiro
Ozaki, Kokoro
Egawa, Satoru
Suzuki, Motohiro
Hirai, Takashi
Ishibashi, Satoru
Ohkubo, Takuya
Yoshii, Toshitaka
Okawa, Atsushi
Yokota, Takanori
author_sort Amano, Eiichiro
collection PubMed
description RATIONALE: OSAM is a rare ventriculoperitoneal (VP) shunt complication where cervical spinal cord compression by epidural venous plexus engorgement is caused by cerebrospinal fluid (CSF) overdrainage. Symmetrically indented deformity of the upper cervical spinal cord and surrounding epidural venous engorgement are characteristic radiological findings. Both of them are typically detected on magnetic resonance imaging (MRI) and enhanced computed tomography (CT). PATIENT CONCERNS: The 77-year-old man who underwent the placement of a VP shunt without an antisiphon device to treat post-subarachnoid hemorrhage (SAH) hydrocephalus presented with progressive quadriplegia 10 years postoperatively. DIAGNOSIS: MRI revealed a symmetrically indented spinal cord from the craniocervical junction (CCJ) to the C2 level and enhanced CT showed the epidural venous engorgement, which were characteristic radiological findings of overshunting-associated myelopathy (OSAM). However, MRI atypically failed to detect the engorged epidural vein and showed no compressive lesion around the spinal cord. INTERVENTION: In order to reveal how the cervical spinal cord was deformed and compressed by engorged epidural vein, CT myelography was performed. OUTCOMES: CT myelography proved that the epidural vein dynamically engorged and compressed the cervical spinal cord immediately after rotation and extension of the neck. LESSONS: CT myelography combined with neck rotation and extension revealed the dynamic change of the epidural venous engorgement, and is useful for evaluation and diagnosis of OSAM especially when epidural venous engorgement was not detectable on MRI.
format Online
Article
Text
id pubmed-5882412
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-58824122018-04-11 Dynamic spinal compression revealed by computed tomography myelography in overshunting-associated myelopathy: A case report Amano, Eiichiro Ozaki, Kokoro Egawa, Satoru Suzuki, Motohiro Hirai, Takashi Ishibashi, Satoru Ohkubo, Takuya Yoshii, Toshitaka Okawa, Atsushi Yokota, Takanori Medicine (Baltimore) 5300 RATIONALE: OSAM is a rare ventriculoperitoneal (VP) shunt complication where cervical spinal cord compression by epidural venous plexus engorgement is caused by cerebrospinal fluid (CSF) overdrainage. Symmetrically indented deformity of the upper cervical spinal cord and surrounding epidural venous engorgement are characteristic radiological findings. Both of them are typically detected on magnetic resonance imaging (MRI) and enhanced computed tomography (CT). PATIENT CONCERNS: The 77-year-old man who underwent the placement of a VP shunt without an antisiphon device to treat post-subarachnoid hemorrhage (SAH) hydrocephalus presented with progressive quadriplegia 10 years postoperatively. DIAGNOSIS: MRI revealed a symmetrically indented spinal cord from the craniocervical junction (CCJ) to the C2 level and enhanced CT showed the epidural venous engorgement, which were characteristic radiological findings of overshunting-associated myelopathy (OSAM). However, MRI atypically failed to detect the engorged epidural vein and showed no compressive lesion around the spinal cord. INTERVENTION: In order to reveal how the cervical spinal cord was deformed and compressed by engorged epidural vein, CT myelography was performed. OUTCOMES: CT myelography proved that the epidural vein dynamically engorged and compressed the cervical spinal cord immediately after rotation and extension of the neck. LESSONS: CT myelography combined with neck rotation and extension revealed the dynamic change of the epidural venous engorgement, and is useful for evaluation and diagnosis of OSAM especially when epidural venous engorgement was not detectable on MRI. Wolters Kluwer Health 2018-03-09 /pmc/articles/PMC5882412/ /pubmed/29517672 http://dx.doi.org/10.1097/MD.0000000000010082 Text en Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NoDerivatives License 4.0, which allows for redistribution, commercial and non-commercial, as long as it is passed along unchanged and in whole, with credit to the author. http://creativecommons.org/licenses/by-nd/4.0
spellingShingle 5300
Amano, Eiichiro
Ozaki, Kokoro
Egawa, Satoru
Suzuki, Motohiro
Hirai, Takashi
Ishibashi, Satoru
Ohkubo, Takuya
Yoshii, Toshitaka
Okawa, Atsushi
Yokota, Takanori
Dynamic spinal compression revealed by computed tomography myelography in overshunting-associated myelopathy: A case report
title Dynamic spinal compression revealed by computed tomography myelography in overshunting-associated myelopathy: A case report
title_full Dynamic spinal compression revealed by computed tomography myelography in overshunting-associated myelopathy: A case report
title_fullStr Dynamic spinal compression revealed by computed tomography myelography in overshunting-associated myelopathy: A case report
title_full_unstemmed Dynamic spinal compression revealed by computed tomography myelography in overshunting-associated myelopathy: A case report
title_short Dynamic spinal compression revealed by computed tomography myelography in overshunting-associated myelopathy: A case report
title_sort dynamic spinal compression revealed by computed tomography myelography in overshunting-associated myelopathy: a case report
topic 5300
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5882412/
https://www.ncbi.nlm.nih.gov/pubmed/29517672
http://dx.doi.org/10.1097/MD.0000000000010082
work_keys_str_mv AT amanoeiichiro dynamicspinalcompressionrevealedbycomputedtomographymyelographyinovershuntingassociatedmyelopathyacasereport
AT ozakikokoro dynamicspinalcompressionrevealedbycomputedtomographymyelographyinovershuntingassociatedmyelopathyacasereport
AT egawasatoru dynamicspinalcompressionrevealedbycomputedtomographymyelographyinovershuntingassociatedmyelopathyacasereport
AT suzukimotohiro dynamicspinalcompressionrevealedbycomputedtomographymyelographyinovershuntingassociatedmyelopathyacasereport
AT hiraitakashi dynamicspinalcompressionrevealedbycomputedtomographymyelographyinovershuntingassociatedmyelopathyacasereport
AT ishibashisatoru dynamicspinalcompressionrevealedbycomputedtomographymyelographyinovershuntingassociatedmyelopathyacasereport
AT ohkubotakuya dynamicspinalcompressionrevealedbycomputedtomographymyelographyinovershuntingassociatedmyelopathyacasereport
AT yoshiitoshitaka dynamicspinalcompressionrevealedbycomputedtomographymyelographyinovershuntingassociatedmyelopathyacasereport
AT okawaatsushi dynamicspinalcompressionrevealedbycomputedtomographymyelographyinovershuntingassociatedmyelopathyacasereport
AT yokotatakanori dynamicspinalcompressionrevealedbycomputedtomographymyelographyinovershuntingassociatedmyelopathyacasereport