Cargando…
One-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more?
PURPOSE: To compare the performance of one-view digital breast tomosynthesis (1v-DBT) to that of three other protocols combining DBT and mammography (DM) for breast cancer detection. MATERIALS AND METHODS: Six radiologists, three experienced with 1v-DBT in screening, retrospectively reviewed 181 cas...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2017
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5882639/ https://www.ncbi.nlm.nih.gov/pubmed/29230524 http://dx.doi.org/10.1007/s00330-017-5167-3 |
_version_ | 1783311487184404480 |
---|---|
author | Rodriguez-Ruiz, Alejandro Gubern-Merida, Albert Imhof-Tas, Mechli Lardenoije, Susanne Wanders, Alexander J. T. Andersson, Ingvar Zackrisson, Sophia Lång, Kristina Dustler, Magnus Karssemeijer, Nico Mann, Ritse M. Sechopoulos, Ioannis |
author_facet | Rodriguez-Ruiz, Alejandro Gubern-Merida, Albert Imhof-Tas, Mechli Lardenoije, Susanne Wanders, Alexander J. T. Andersson, Ingvar Zackrisson, Sophia Lång, Kristina Dustler, Magnus Karssemeijer, Nico Mann, Ritse M. Sechopoulos, Ioannis |
author_sort | Rodriguez-Ruiz, Alejandro |
collection | PubMed |
description | PURPOSE: To compare the performance of one-view digital breast tomosynthesis (1v-DBT) to that of three other protocols combining DBT and mammography (DM) for breast cancer detection. MATERIALS AND METHODS: Six radiologists, three experienced with 1v-DBT in screening, retrospectively reviewed 181 cases (76 malignant, 50 benign, 55 normal) in two sessions. First, they scored sequentially: 1v-DBT (medio-lateral oblique, MLO), 1v-DBT (MLO) + 1v-DM (cranio-caudal, CC) and two-view DM + DBT (2v-DM+2v-DBT). The second session involved only 2v-DM. Lesions were scored using BI-RADS® and level of suspiciousness (1–10). Sensitivity, specificity, receiver operating characteristic (ROC) and jack-knife alternative free-response ROC (JAFROC) were computed. RESULTS: On average, 1v-DBT was non-inferior to any of the other protocols in terms of JAFROC figure-of-merit, area under ROC curve, sensitivity or specificity (p>0.391). While readers inexperienced with 1v-DBT screening improved their sensitivity when adding more images (69–79 %, p=0.019), experienced readers showed similar sensitivity (76 %) and specificity (70 %) between 1v-DBT and 2v-DM+2v-DBT (p=0.482). Subanalysis by lesion type and breast density showed no difference among modalities. CONCLUSION: Detection performance with 1v-DBT is not statistically inferior to 2v-DM or to 2v-DM+2v-DBT; its use as a stand-alone modality might be sufficient for readers experienced with this protocol. KEY POINTS: • One-view breast tomosynthesis is not inferior to two-view digital mammography. • One-view DBT is not inferior to 2-view DM plus 2-view DBT. • Training may lead to 1v-DBT being sufficient for screening. |
format | Online Article Text |
id | pubmed-5882639 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2017 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-58826392018-04-05 One-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more? Rodriguez-Ruiz, Alejandro Gubern-Merida, Albert Imhof-Tas, Mechli Lardenoije, Susanne Wanders, Alexander J. T. Andersson, Ingvar Zackrisson, Sophia Lång, Kristina Dustler, Magnus Karssemeijer, Nico Mann, Ritse M. Sechopoulos, Ioannis Eur Radiol Breast PURPOSE: To compare the performance of one-view digital breast tomosynthesis (1v-DBT) to that of three other protocols combining DBT and mammography (DM) for breast cancer detection. MATERIALS AND METHODS: Six radiologists, three experienced with 1v-DBT in screening, retrospectively reviewed 181 cases (76 malignant, 50 benign, 55 normal) in two sessions. First, they scored sequentially: 1v-DBT (medio-lateral oblique, MLO), 1v-DBT (MLO) + 1v-DM (cranio-caudal, CC) and two-view DM + DBT (2v-DM+2v-DBT). The second session involved only 2v-DM. Lesions were scored using BI-RADS® and level of suspiciousness (1–10). Sensitivity, specificity, receiver operating characteristic (ROC) and jack-knife alternative free-response ROC (JAFROC) were computed. RESULTS: On average, 1v-DBT was non-inferior to any of the other protocols in terms of JAFROC figure-of-merit, area under ROC curve, sensitivity or specificity (p>0.391). While readers inexperienced with 1v-DBT screening improved their sensitivity when adding more images (69–79 %, p=0.019), experienced readers showed similar sensitivity (76 %) and specificity (70 %) between 1v-DBT and 2v-DM+2v-DBT (p=0.482). Subanalysis by lesion type and breast density showed no difference among modalities. CONCLUSION: Detection performance with 1v-DBT is not statistically inferior to 2v-DM or to 2v-DM+2v-DBT; its use as a stand-alone modality might be sufficient for readers experienced with this protocol. KEY POINTS: • One-view breast tomosynthesis is not inferior to two-view digital mammography. • One-view DBT is not inferior to 2-view DM plus 2-view DBT. • Training may lead to 1v-DBT being sufficient for screening. Springer Berlin Heidelberg 2017-12-11 2018 /pmc/articles/PMC5882639/ /pubmed/29230524 http://dx.doi.org/10.1007/s00330-017-5167-3 Text en © The Author(s) 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
spellingShingle | Breast Rodriguez-Ruiz, Alejandro Gubern-Merida, Albert Imhof-Tas, Mechli Lardenoije, Susanne Wanders, Alexander J. T. Andersson, Ingvar Zackrisson, Sophia Lång, Kristina Dustler, Magnus Karssemeijer, Nico Mann, Ritse M. Sechopoulos, Ioannis One-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more? |
title | One-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more? |
title_full | One-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more? |
title_fullStr | One-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more? |
title_full_unstemmed | One-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more? |
title_short | One-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more? |
title_sort | one-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more? |
topic | Breast |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5882639/ https://www.ncbi.nlm.nih.gov/pubmed/29230524 http://dx.doi.org/10.1007/s00330-017-5167-3 |
work_keys_str_mv | AT rodriguezruizalejandro oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore AT gubernmeridaalbert oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore AT imhoftasmechli oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore AT lardenoijesusanne oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore AT wandersalexanderjt oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore AT anderssoningvar oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore AT zackrissonsophia oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore AT langkristina oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore AT dustlermagnus oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore AT karssemeijernico oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore AT mannritsem oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore AT sechopoulosioannis oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore |