Cargando…

One-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more?

PURPOSE: To compare the performance of one-view digital breast tomosynthesis (1v-DBT) to that of three other protocols combining DBT and mammography (DM) for breast cancer detection. MATERIALS AND METHODS: Six radiologists, three experienced with 1v-DBT in screening, retrospectively reviewed 181 cas...

Descripción completa

Detalles Bibliográficos
Autores principales: Rodriguez-Ruiz, Alejandro, Gubern-Merida, Albert, Imhof-Tas, Mechli, Lardenoije, Susanne, Wanders, Alexander J. T., Andersson, Ingvar, Zackrisson, Sophia, Lång, Kristina, Dustler, Magnus, Karssemeijer, Nico, Mann, Ritse M., Sechopoulos, Ioannis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2017
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5882639/
https://www.ncbi.nlm.nih.gov/pubmed/29230524
http://dx.doi.org/10.1007/s00330-017-5167-3
_version_ 1783311487184404480
author Rodriguez-Ruiz, Alejandro
Gubern-Merida, Albert
Imhof-Tas, Mechli
Lardenoije, Susanne
Wanders, Alexander J. T.
Andersson, Ingvar
Zackrisson, Sophia
Lång, Kristina
Dustler, Magnus
Karssemeijer, Nico
Mann, Ritse M.
Sechopoulos, Ioannis
author_facet Rodriguez-Ruiz, Alejandro
Gubern-Merida, Albert
Imhof-Tas, Mechli
Lardenoije, Susanne
Wanders, Alexander J. T.
Andersson, Ingvar
Zackrisson, Sophia
Lång, Kristina
Dustler, Magnus
Karssemeijer, Nico
Mann, Ritse M.
Sechopoulos, Ioannis
author_sort Rodriguez-Ruiz, Alejandro
collection PubMed
description PURPOSE: To compare the performance of one-view digital breast tomosynthesis (1v-DBT) to that of three other protocols combining DBT and mammography (DM) for breast cancer detection. MATERIALS AND METHODS: Six radiologists, three experienced with 1v-DBT in screening, retrospectively reviewed 181 cases (76 malignant, 50 benign, 55 normal) in two sessions. First, they scored sequentially: 1v-DBT (medio-lateral oblique, MLO), 1v-DBT (MLO) + 1v-DM (cranio-caudal, CC) and two-view DM + DBT (2v-DM+2v-DBT). The second session involved only 2v-DM. Lesions were scored using BI-RADS® and level of suspiciousness (1–10). Sensitivity, specificity, receiver operating characteristic (ROC) and jack-knife alternative free-response ROC (JAFROC) were computed. RESULTS: On average, 1v-DBT was non-inferior to any of the other protocols in terms of JAFROC figure-of-merit, area under ROC curve, sensitivity or specificity (p>0.391). While readers inexperienced with 1v-DBT screening improved their sensitivity when adding more images (69–79 %, p=0.019), experienced readers showed similar sensitivity (76 %) and specificity (70 %) between 1v-DBT and 2v-DM+2v-DBT (p=0.482). Subanalysis by lesion type and breast density showed no difference among modalities. CONCLUSION: Detection performance with 1v-DBT is not statistically inferior to 2v-DM or to 2v-DM+2v-DBT; its use as a stand-alone modality might be sufficient for readers experienced with this protocol. KEY POINTS: • One-view breast tomosynthesis is not inferior to two-view digital mammography. • One-view DBT is not inferior to 2-view DM plus 2-view DBT. • Training may lead to 1v-DBT being sufficient for screening.
format Online
Article
Text
id pubmed-5882639
institution National Center for Biotechnology Information
language English
publishDate 2017
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-58826392018-04-05 One-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more? Rodriguez-Ruiz, Alejandro Gubern-Merida, Albert Imhof-Tas, Mechli Lardenoije, Susanne Wanders, Alexander J. T. Andersson, Ingvar Zackrisson, Sophia Lång, Kristina Dustler, Magnus Karssemeijer, Nico Mann, Ritse M. Sechopoulos, Ioannis Eur Radiol Breast PURPOSE: To compare the performance of one-view digital breast tomosynthesis (1v-DBT) to that of three other protocols combining DBT and mammography (DM) for breast cancer detection. MATERIALS AND METHODS: Six radiologists, three experienced with 1v-DBT in screening, retrospectively reviewed 181 cases (76 malignant, 50 benign, 55 normal) in two sessions. First, they scored sequentially: 1v-DBT (medio-lateral oblique, MLO), 1v-DBT (MLO) + 1v-DM (cranio-caudal, CC) and two-view DM + DBT (2v-DM+2v-DBT). The second session involved only 2v-DM. Lesions were scored using BI-RADS® and level of suspiciousness (1–10). Sensitivity, specificity, receiver operating characteristic (ROC) and jack-knife alternative free-response ROC (JAFROC) were computed. RESULTS: On average, 1v-DBT was non-inferior to any of the other protocols in terms of JAFROC figure-of-merit, area under ROC curve, sensitivity or specificity (p>0.391). While readers inexperienced with 1v-DBT screening improved their sensitivity when adding more images (69–79 %, p=0.019), experienced readers showed similar sensitivity (76 %) and specificity (70 %) between 1v-DBT and 2v-DM+2v-DBT (p=0.482). Subanalysis by lesion type and breast density showed no difference among modalities. CONCLUSION: Detection performance with 1v-DBT is not statistically inferior to 2v-DM or to 2v-DM+2v-DBT; its use as a stand-alone modality might be sufficient for readers experienced with this protocol. KEY POINTS: • One-view breast tomosynthesis is not inferior to two-view digital mammography. • One-view DBT is not inferior to 2-view DM plus 2-view DBT. • Training may lead to 1v-DBT being sufficient for screening. Springer Berlin Heidelberg 2017-12-11 2018 /pmc/articles/PMC5882639/ /pubmed/29230524 http://dx.doi.org/10.1007/s00330-017-5167-3 Text en © The Author(s) 2017 Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Breast
Rodriguez-Ruiz, Alejandro
Gubern-Merida, Albert
Imhof-Tas, Mechli
Lardenoije, Susanne
Wanders, Alexander J. T.
Andersson, Ingvar
Zackrisson, Sophia
Lång, Kristina
Dustler, Magnus
Karssemeijer, Nico
Mann, Ritse M.
Sechopoulos, Ioannis
One-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more?
title One-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more?
title_full One-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more?
title_fullStr One-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more?
title_full_unstemmed One-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more?
title_short One-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more?
title_sort one-view digital breast tomosynthesis as a stand-alone modality for breast cancer detection: do we need more?
topic Breast
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5882639/
https://www.ncbi.nlm.nih.gov/pubmed/29230524
http://dx.doi.org/10.1007/s00330-017-5167-3
work_keys_str_mv AT rodriguezruizalejandro oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore
AT gubernmeridaalbert oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore
AT imhoftasmechli oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore
AT lardenoijesusanne oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore
AT wandersalexanderjt oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore
AT anderssoningvar oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore
AT zackrissonsophia oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore
AT langkristina oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore
AT dustlermagnus oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore
AT karssemeijernico oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore
AT mannritsem oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore
AT sechopoulosioannis oneviewdigitalbreasttomosynthesisasastandalonemodalityforbreastcancerdetectiondoweneedmore