Cargando…
Susceptibility-induced distortion that varies due to motion: Correction in diffusion MR without acquiring additional data
Because of their low bandwidth in the phase-encode (PE) direction, the susceptibility-induced off-resonance field causes distortions in echo planar imaging (EPI) images. It is therefore crucial to correct for susceptibility-induced distortions when performing diffusion studies using EPI. The suscept...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Academic Press
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5883370/ https://www.ncbi.nlm.nih.gov/pubmed/29277648 http://dx.doi.org/10.1016/j.neuroimage.2017.12.040 |
_version_ | 1783311637099315200 |
---|---|
author | Andersson, Jesper L.R. Graham, Mark S. Drobnjak, Ivana Zhang, Hui Campbell, Jon |
author_facet | Andersson, Jesper L.R. Graham, Mark S. Drobnjak, Ivana Zhang, Hui Campbell, Jon |
author_sort | Andersson, Jesper L.R. |
collection | PubMed |
description | Because of their low bandwidth in the phase-encode (PE) direction, the susceptibility-induced off-resonance field causes distortions in echo planar imaging (EPI) images. It is therefore crucial to correct for susceptibility-induced distortions when performing diffusion studies using EPI. The susceptibility-induced field is caused by the object (head) disrupting the field and it is typically assumed that it remains constant within a framework defined by the object, (i.e. it follows the object as it moves in the scanner). However, this is only approximately true. When a non-spherical object rotates around an axis other than that parallel with the magnetic flux (the z-axis) it changes the way it disrupts the field, leading to different distortions. Hence, if using a single field to correct for distortions there will be residual distortions in the volumes where the object orientation is substantially different to that when the field was measured. In this paper we present a post-processing method for estimating the field as it changes with motion during the course of an experiment. It only requires a single measured field and knowledge of the orientation of the subject when that field was acquired. The volume-to-volume changes of the field as a consequence of subject movement are estimated directly from the diffusion data without the need for any additional or special acquisitions. It uses a generative model that predicts how each volume would look predicated on field change and inverts that model to yield an estimate of the field changes. It has been validated on both simulations and experimental data. The results show that we are able to track the field with high accuracy and that we are able to correct the data for the adverse effects of the changing field. |
format | Online Article Text |
id | pubmed-5883370 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Academic Press |
record_format | MEDLINE/PubMed |
spelling | pubmed-58833702018-05-01 Susceptibility-induced distortion that varies due to motion: Correction in diffusion MR without acquiring additional data Andersson, Jesper L.R. Graham, Mark S. Drobnjak, Ivana Zhang, Hui Campbell, Jon Neuroimage Article Because of their low bandwidth in the phase-encode (PE) direction, the susceptibility-induced off-resonance field causes distortions in echo planar imaging (EPI) images. It is therefore crucial to correct for susceptibility-induced distortions when performing diffusion studies using EPI. The susceptibility-induced field is caused by the object (head) disrupting the field and it is typically assumed that it remains constant within a framework defined by the object, (i.e. it follows the object as it moves in the scanner). However, this is only approximately true. When a non-spherical object rotates around an axis other than that parallel with the magnetic flux (the z-axis) it changes the way it disrupts the field, leading to different distortions. Hence, if using a single field to correct for distortions there will be residual distortions in the volumes where the object orientation is substantially different to that when the field was measured. In this paper we present a post-processing method for estimating the field as it changes with motion during the course of an experiment. It only requires a single measured field and knowledge of the orientation of the subject when that field was acquired. The volume-to-volume changes of the field as a consequence of subject movement are estimated directly from the diffusion data without the need for any additional or special acquisitions. It uses a generative model that predicts how each volume would look predicated on field change and inverts that model to yield an estimate of the field changes. It has been validated on both simulations and experimental data. The results show that we are able to track the field with high accuracy and that we are able to correct the data for the adverse effects of the changing field. Academic Press 2018-05-01 /pmc/articles/PMC5883370/ /pubmed/29277648 http://dx.doi.org/10.1016/j.neuroimage.2017.12.040 Text en © 2017 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Andersson, Jesper L.R. Graham, Mark S. Drobnjak, Ivana Zhang, Hui Campbell, Jon Susceptibility-induced distortion that varies due to motion: Correction in diffusion MR without acquiring additional data |
title | Susceptibility-induced distortion that varies due to motion: Correction in diffusion MR without acquiring additional data |
title_full | Susceptibility-induced distortion that varies due to motion: Correction in diffusion MR without acquiring additional data |
title_fullStr | Susceptibility-induced distortion that varies due to motion: Correction in diffusion MR without acquiring additional data |
title_full_unstemmed | Susceptibility-induced distortion that varies due to motion: Correction in diffusion MR without acquiring additional data |
title_short | Susceptibility-induced distortion that varies due to motion: Correction in diffusion MR without acquiring additional data |
title_sort | susceptibility-induced distortion that varies due to motion: correction in diffusion mr without acquiring additional data |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5883370/ https://www.ncbi.nlm.nih.gov/pubmed/29277648 http://dx.doi.org/10.1016/j.neuroimage.2017.12.040 |
work_keys_str_mv | AT anderssonjesperlr susceptibilityinduceddistortionthatvariesduetomotioncorrectionindiffusionmrwithoutacquiringadditionaldata AT grahammarks susceptibilityinduceddistortionthatvariesduetomotioncorrectionindiffusionmrwithoutacquiringadditionaldata AT drobnjakivana susceptibilityinduceddistortionthatvariesduetomotioncorrectionindiffusionmrwithoutacquiringadditionaldata AT zhanghui susceptibilityinduceddistortionthatvariesduetomotioncorrectionindiffusionmrwithoutacquiringadditionaldata AT campbelljon susceptibilityinduceddistortionthatvariesduetomotioncorrectionindiffusionmrwithoutacquiringadditionaldata |