Cargando…
Intra-session and Inter-day Reliability of the Myon 320 Electromyography System During Sub-maximal Contractions
Electromyography systems are widely used within the field of scientific and clinical practices. The reliability of these systems are paramount when conducting research. The reliability of Myon 320 Surface Electromyography System is yet to be determined. This study aims to determine the intra-session...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5884956/ https://www.ncbi.nlm.nih.gov/pubmed/29651252 http://dx.doi.org/10.3389/fphys.2018.00309 |
_version_ | 1783311912920940544 |
---|---|
author | Sorbie, Graeme G. Williams, Michael J. Boyle, David W. Gray, Alexander Brouner, James Gibson, Neil Baker, Julien S. Easton, Chris Ugbolue, Ukadike C. |
author_facet | Sorbie, Graeme G. Williams, Michael J. Boyle, David W. Gray, Alexander Brouner, James Gibson, Neil Baker, Julien S. Easton, Chris Ugbolue, Ukadike C. |
author_sort | Sorbie, Graeme G. |
collection | PubMed |
description | Electromyography systems are widely used within the field of scientific and clinical practices. The reliability of these systems are paramount when conducting research. The reliability of Myon 320 Surface Electromyography System is yet to be determined. This study aims to determine the intra-session and inter-day reliability of the Myon 320 Surface Electromyography System. Muscle activity from fifteen participants was measured at the anterior deltoid muscle during a bilateral front raise exercise, the vastus lateralis muscle during a squat exercise and the extensor carpi radialis brevis (ECRB) muscle during an isometric handgrip task. Intra-session and inter-day reliability was calculated by intraclass correlation coefficient, standard error of measurement and coefficient of variation (CV). The normalized root mean squared (RMS) surface electromyographic signals produced good intra-session and inter-day testing intraclass correlation coefficient values (range: 0.63–0.97) together with low standard error of measurement (range: 1.49–2.32) and CV (range: 95% Confidence Interval = 0.36–12.71) measures for the dynamic-and-isometric contractions. The findings indicate that the Myon 320 Surface Electromyography System produces good to fair reliability when examining intra-session and inter-day reliability. Findings of the study provide evidence of the reliability of electromyography between trials which is essential during clinical testing. |
format | Online Article Text |
id | pubmed-5884956 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-58849562018-04-12 Intra-session and Inter-day Reliability of the Myon 320 Electromyography System During Sub-maximal Contractions Sorbie, Graeme G. Williams, Michael J. Boyle, David W. Gray, Alexander Brouner, James Gibson, Neil Baker, Julien S. Easton, Chris Ugbolue, Ukadike C. Front Physiol Physiology Electromyography systems are widely used within the field of scientific and clinical practices. The reliability of these systems are paramount when conducting research. The reliability of Myon 320 Surface Electromyography System is yet to be determined. This study aims to determine the intra-session and inter-day reliability of the Myon 320 Surface Electromyography System. Muscle activity from fifteen participants was measured at the anterior deltoid muscle during a bilateral front raise exercise, the vastus lateralis muscle during a squat exercise and the extensor carpi radialis brevis (ECRB) muscle during an isometric handgrip task. Intra-session and inter-day reliability was calculated by intraclass correlation coefficient, standard error of measurement and coefficient of variation (CV). The normalized root mean squared (RMS) surface electromyographic signals produced good intra-session and inter-day testing intraclass correlation coefficient values (range: 0.63–0.97) together with low standard error of measurement (range: 1.49–2.32) and CV (range: 95% Confidence Interval = 0.36–12.71) measures for the dynamic-and-isometric contractions. The findings indicate that the Myon 320 Surface Electromyography System produces good to fair reliability when examining intra-session and inter-day reliability. Findings of the study provide evidence of the reliability of electromyography between trials which is essential during clinical testing. Frontiers Media S.A. 2018-03-29 /pmc/articles/PMC5884956/ /pubmed/29651252 http://dx.doi.org/10.3389/fphys.2018.00309 Text en Copyright © 2018 Sorbie, Williams, Boyle, Gray, Brouner, Gibson, Baker, Easton and Ugbolue. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Physiology Sorbie, Graeme G. Williams, Michael J. Boyle, David W. Gray, Alexander Brouner, James Gibson, Neil Baker, Julien S. Easton, Chris Ugbolue, Ukadike C. Intra-session and Inter-day Reliability of the Myon 320 Electromyography System During Sub-maximal Contractions |
title | Intra-session and Inter-day Reliability of the Myon 320 Electromyography System During Sub-maximal Contractions |
title_full | Intra-session and Inter-day Reliability of the Myon 320 Electromyography System During Sub-maximal Contractions |
title_fullStr | Intra-session and Inter-day Reliability of the Myon 320 Electromyography System During Sub-maximal Contractions |
title_full_unstemmed | Intra-session and Inter-day Reliability of the Myon 320 Electromyography System During Sub-maximal Contractions |
title_short | Intra-session and Inter-day Reliability of the Myon 320 Electromyography System During Sub-maximal Contractions |
title_sort | intra-session and inter-day reliability of the myon 320 electromyography system during sub-maximal contractions |
topic | Physiology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5884956/ https://www.ncbi.nlm.nih.gov/pubmed/29651252 http://dx.doi.org/10.3389/fphys.2018.00309 |
work_keys_str_mv | AT sorbiegraemeg intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions AT williamsmichaelj intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions AT boyledavidw intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions AT grayalexander intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions AT brounerjames intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions AT gibsonneil intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions AT bakerjuliens intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions AT eastonchris intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions AT ugbolueukadikec intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions |