Cargando…

Intra-session and Inter-day Reliability of the Myon 320 Electromyography System During Sub-maximal Contractions

Electromyography systems are widely used within the field of scientific and clinical practices. The reliability of these systems are paramount when conducting research. The reliability of Myon 320 Surface Electromyography System is yet to be determined. This study aims to determine the intra-session...

Descripción completa

Detalles Bibliográficos
Autores principales: Sorbie, Graeme G., Williams, Michael J., Boyle, David W., Gray, Alexander, Brouner, James, Gibson, Neil, Baker, Julien S., Easton, Chris, Ugbolue, Ukadike C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5884956/
https://www.ncbi.nlm.nih.gov/pubmed/29651252
http://dx.doi.org/10.3389/fphys.2018.00309
_version_ 1783311912920940544
author Sorbie, Graeme G.
Williams, Michael J.
Boyle, David W.
Gray, Alexander
Brouner, James
Gibson, Neil
Baker, Julien S.
Easton, Chris
Ugbolue, Ukadike C.
author_facet Sorbie, Graeme G.
Williams, Michael J.
Boyle, David W.
Gray, Alexander
Brouner, James
Gibson, Neil
Baker, Julien S.
Easton, Chris
Ugbolue, Ukadike C.
author_sort Sorbie, Graeme G.
collection PubMed
description Electromyography systems are widely used within the field of scientific and clinical practices. The reliability of these systems are paramount when conducting research. The reliability of Myon 320 Surface Electromyography System is yet to be determined. This study aims to determine the intra-session and inter-day reliability of the Myon 320 Surface Electromyography System. Muscle activity from fifteen participants was measured at the anterior deltoid muscle during a bilateral front raise exercise, the vastus lateralis muscle during a squat exercise and the extensor carpi radialis brevis (ECRB) muscle during an isometric handgrip task. Intra-session and inter-day reliability was calculated by intraclass correlation coefficient, standard error of measurement and coefficient of variation (CV). The normalized root mean squared (RMS) surface electromyographic signals produced good intra-session and inter-day testing intraclass correlation coefficient values (range: 0.63–0.97) together with low standard error of measurement (range: 1.49–2.32) and CV (range: 95% Confidence Interval = 0.36–12.71) measures for the dynamic-and-isometric contractions. The findings indicate that the Myon 320 Surface Electromyography System produces good to fair reliability when examining intra-session and inter-day reliability. Findings of the study provide evidence of the reliability of electromyography between trials which is essential during clinical testing.
format Online
Article
Text
id pubmed-5884956
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-58849562018-04-12 Intra-session and Inter-day Reliability of the Myon 320 Electromyography System During Sub-maximal Contractions Sorbie, Graeme G. Williams, Michael J. Boyle, David W. Gray, Alexander Brouner, James Gibson, Neil Baker, Julien S. Easton, Chris Ugbolue, Ukadike C. Front Physiol Physiology Electromyography systems are widely used within the field of scientific and clinical practices. The reliability of these systems are paramount when conducting research. The reliability of Myon 320 Surface Electromyography System is yet to be determined. This study aims to determine the intra-session and inter-day reliability of the Myon 320 Surface Electromyography System. Muscle activity from fifteen participants was measured at the anterior deltoid muscle during a bilateral front raise exercise, the vastus lateralis muscle during a squat exercise and the extensor carpi radialis brevis (ECRB) muscle during an isometric handgrip task. Intra-session and inter-day reliability was calculated by intraclass correlation coefficient, standard error of measurement and coefficient of variation (CV). The normalized root mean squared (RMS) surface electromyographic signals produced good intra-session and inter-day testing intraclass correlation coefficient values (range: 0.63–0.97) together with low standard error of measurement (range: 1.49–2.32) and CV (range: 95% Confidence Interval = 0.36–12.71) measures for the dynamic-and-isometric contractions. The findings indicate that the Myon 320 Surface Electromyography System produces good to fair reliability when examining intra-session and inter-day reliability. Findings of the study provide evidence of the reliability of electromyography between trials which is essential during clinical testing. Frontiers Media S.A. 2018-03-29 /pmc/articles/PMC5884956/ /pubmed/29651252 http://dx.doi.org/10.3389/fphys.2018.00309 Text en Copyright © 2018 Sorbie, Williams, Boyle, Gray, Brouner, Gibson, Baker, Easton and Ugbolue. http://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Physiology
Sorbie, Graeme G.
Williams, Michael J.
Boyle, David W.
Gray, Alexander
Brouner, James
Gibson, Neil
Baker, Julien S.
Easton, Chris
Ugbolue, Ukadike C.
Intra-session and Inter-day Reliability of the Myon 320 Electromyography System During Sub-maximal Contractions
title Intra-session and Inter-day Reliability of the Myon 320 Electromyography System During Sub-maximal Contractions
title_full Intra-session and Inter-day Reliability of the Myon 320 Electromyography System During Sub-maximal Contractions
title_fullStr Intra-session and Inter-day Reliability of the Myon 320 Electromyography System During Sub-maximal Contractions
title_full_unstemmed Intra-session and Inter-day Reliability of the Myon 320 Electromyography System During Sub-maximal Contractions
title_short Intra-session and Inter-day Reliability of the Myon 320 Electromyography System During Sub-maximal Contractions
title_sort intra-session and inter-day reliability of the myon 320 electromyography system during sub-maximal contractions
topic Physiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5884956/
https://www.ncbi.nlm.nih.gov/pubmed/29651252
http://dx.doi.org/10.3389/fphys.2018.00309
work_keys_str_mv AT sorbiegraemeg intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions
AT williamsmichaelj intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions
AT boyledavidw intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions
AT grayalexander intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions
AT brounerjames intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions
AT gibsonneil intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions
AT bakerjuliens intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions
AT eastonchris intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions
AT ugbolueukadikec intrasessionandinterdayreliabilityofthemyon320electromyographysystemduringsubmaximalcontractions