Cargando…

Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy

Ultrasound (US)-guided breast biopsy has become the main method for diagnosing breast pathology, and it has a high diagnostic accuracy, approaching that of open surgical biopsy. However, methods for confirming adequate lesion retrieval after US-guided biopsy are relatively limited and false-negative...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Vivian Youngjean, Kim, Eun-Kyung, Moon, Hee Jung, Yoon, Jung Hyun, Kim, Min Jung
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Korean Society of Ultrasound in Medicine 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5885481/
https://www.ncbi.nlm.nih.gov/pubmed/29169231
http://dx.doi.org/10.14366/usg.17049
_version_ 1783311998649368576
author Park, Vivian Youngjean
Kim, Eun-Kyung
Moon, Hee Jung
Yoon, Jung Hyun
Kim, Min Jung
author_facet Park, Vivian Youngjean
Kim, Eun-Kyung
Moon, Hee Jung
Yoon, Jung Hyun
Kim, Min Jung
author_sort Park, Vivian Youngjean
collection PubMed
description Ultrasound (US)-guided breast biopsy has become the main method for diagnosing breast pathology, and it has a high diagnostic accuracy, approaching that of open surgical biopsy. However, methods for confirming adequate lesion retrieval after US-guided biopsy are relatively limited and false-negative results are unavoidable. Determining imaging-pathology concordance after US-guided biopsy is essential for validating the biopsy result and providing appropriate management. In this review article, we briefly present the results of US-guided breast biopsy; describe general aspects to consider when establishing imaging-pathology concordance; and review the various categories of imaging-pathology correlations and corresponding management strategies.
format Online
Article
Text
id pubmed-5885481
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Korean Society of Ultrasound in Medicine
record_format MEDLINE/PubMed
spelling pubmed-58854812018-04-06 Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy Park, Vivian Youngjean Kim, Eun-Kyung Moon, Hee Jung Yoon, Jung Hyun Kim, Min Jung Ultrasonography Review Article Ultrasound (US)-guided breast biopsy has become the main method for diagnosing breast pathology, and it has a high diagnostic accuracy, approaching that of open surgical biopsy. However, methods for confirming adequate lesion retrieval after US-guided biopsy are relatively limited and false-negative results are unavoidable. Determining imaging-pathology concordance after US-guided biopsy is essential for validating the biopsy result and providing appropriate management. In this review article, we briefly present the results of US-guided breast biopsy; describe general aspects to consider when establishing imaging-pathology concordance; and review the various categories of imaging-pathology correlations and corresponding management strategies. Korean Society of Ultrasound in Medicine 2018-04 2017-08-19 /pmc/articles/PMC5885481/ /pubmed/29169231 http://dx.doi.org/10.14366/usg.17049 Text en Copyright © 2018 Korean Society of Ultrasound in Medicine (KSUM) This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Park, Vivian Youngjean
Kim, Eun-Kyung
Moon, Hee Jung
Yoon, Jung Hyun
Kim, Min Jung
Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy
title Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy
title_full Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy
title_fullStr Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy
title_full_unstemmed Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy
title_short Evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy
title_sort evaluating imaging-pathology concordance and discordance after ultrasound-guided breast biopsy
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5885481/
https://www.ncbi.nlm.nih.gov/pubmed/29169231
http://dx.doi.org/10.14366/usg.17049
work_keys_str_mv AT parkvivianyoungjean evaluatingimagingpathologyconcordanceanddiscordanceafterultrasoundguidedbreastbiopsy
AT kimeunkyung evaluatingimagingpathologyconcordanceanddiscordanceafterultrasoundguidedbreastbiopsy
AT moonheejung evaluatingimagingpathologyconcordanceanddiscordanceafterultrasoundguidedbreastbiopsy
AT yoonjunghyun evaluatingimagingpathologyconcordanceanddiscordanceafterultrasoundguidedbreastbiopsy
AT kimminjung evaluatingimagingpathologyconcordanceanddiscordanceafterultrasoundguidedbreastbiopsy