Cargando…

Sonographers' self‐reported visualization of normal postmenopausal ovaries on transvaginal ultrasound is not reliable: results of expert review of archived images from UKCTOCS

OBJECTIVE: In the UK Collaborative Trial of Ovarian Cancer Screening (UKCTOCS), self‐reported visualization rate (VR) of the ovaries by the sonographer on annual transvaginal sonographic (TVS) examinations was a key quality control (QC) metric. The objective of this study was to assess self‐reported...

Descripción completa

Detalles Bibliográficos
Autores principales: Stott, W., Campbell, S., Franchini, A., Blyuss, O., Zaikin, A., Ryan, A., Jones, C., Gentry‐Maharaj, A., Fletcher, G., Kalsi, J., Skates, S., Parmar, M., Amso, N., Jacobs, I., Menon, U.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley & Sons, Ltd. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5888153/
https://www.ncbi.nlm.nih.gov/pubmed/28796383
http://dx.doi.org/10.1002/uog.18836
_version_ 1783312458766614528
author Stott, W.
Campbell, S.
Franchini, A.
Blyuss, O.
Zaikin, A.
Ryan, A.
Jones, C.
Gentry‐Maharaj, A.
Fletcher, G.
Kalsi, J.
Skates, S.
Parmar, M.
Amso, N.
Jacobs, I.
Menon, U.
author_facet Stott, W.
Campbell, S.
Franchini, A.
Blyuss, O.
Zaikin, A.
Ryan, A.
Jones, C.
Gentry‐Maharaj, A.
Fletcher, G.
Kalsi, J.
Skates, S.
Parmar, M.
Amso, N.
Jacobs, I.
Menon, U.
author_sort Stott, W.
collection PubMed
description OBJECTIVE: In the UK Collaborative Trial of Ovarian Cancer Screening (UKCTOCS), self‐reported visualization rate (VR) of the ovaries by the sonographer on annual transvaginal sonographic (TVS) examinations was a key quality control (QC) metric. The objective of this study was to assess self‐reported VR using expert review of a random sample of archived images of TVS examinations from UKCTOCS, and then to develop software for measuring VR automatically. METHODS: A single expert reviewed images archived from 1000 TVS examinations selected randomly from 68 931 TVS scans performed in UKCTOCS between 2008 and 2011 with ovaries reported as ‘seen and normal’. Software was developed to identify the exact images used by the sonographer to measure the ovaries. This was achieved by measuring caliper dimensions in the image and matching them to those recorded by the sonographer. A logistic regression classifier to determine visualization was trained and validated using ovarian dimensions and visualization data reported by the expert. RESULTS: The expert reviewer confirmed visualization of both ovaries (VR‐Both) in 50.2% (502/1000) of the examinations. The software identified the measurement image in 534 exams, which were split 2:1:1 providing training, validation and test data. Classifier mean accuracy on validation data was 70.9% (95% CI, 70.0–71.8%). Analysis of test data (133 exams) provided a sensitivity of 90.5% (95% CI, 80.9–95.8%) and specificity of 47.5% (95% CI, 34.5–60.8%) in detecting expert confirmed visualization of both ovaries. CONCLUSIONS: Our results suggest that, in a significant proportion of TVS annual screens, the sonographers may have mistaken other structures for normal ovaries. It is uncertain whether or not this affected the sensitivity and stage at detection of ovarian cancer in the ultrasound arm of UKCTOCS, but we conclude that QC metrics based on self‐reported visualization of normal ovaries are unreliable. The classifier shows some potential for addressing this problem, though further research is needed. © 2017 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology.
format Online
Article
Text
id pubmed-5888153
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher John Wiley & Sons, Ltd.
record_format MEDLINE/PubMed
spelling pubmed-58881532018-04-12 Sonographers' self‐reported visualization of normal postmenopausal ovaries on transvaginal ultrasound is not reliable: results of expert review of archived images from UKCTOCS Stott, W. Campbell, S. Franchini, A. Blyuss, O. Zaikin, A. Ryan, A. Jones, C. Gentry‐Maharaj, A. Fletcher, G. Kalsi, J. Skates, S. Parmar, M. Amso, N. Jacobs, I. Menon, U. Ultrasound Obstet Gynecol Original Papers OBJECTIVE: In the UK Collaborative Trial of Ovarian Cancer Screening (UKCTOCS), self‐reported visualization rate (VR) of the ovaries by the sonographer on annual transvaginal sonographic (TVS) examinations was a key quality control (QC) metric. The objective of this study was to assess self‐reported VR using expert review of a random sample of archived images of TVS examinations from UKCTOCS, and then to develop software for measuring VR automatically. METHODS: A single expert reviewed images archived from 1000 TVS examinations selected randomly from 68 931 TVS scans performed in UKCTOCS between 2008 and 2011 with ovaries reported as ‘seen and normal’. Software was developed to identify the exact images used by the sonographer to measure the ovaries. This was achieved by measuring caliper dimensions in the image and matching them to those recorded by the sonographer. A logistic regression classifier to determine visualization was trained and validated using ovarian dimensions and visualization data reported by the expert. RESULTS: The expert reviewer confirmed visualization of both ovaries (VR‐Both) in 50.2% (502/1000) of the examinations. The software identified the measurement image in 534 exams, which were split 2:1:1 providing training, validation and test data. Classifier mean accuracy on validation data was 70.9% (95% CI, 70.0–71.8%). Analysis of test data (133 exams) provided a sensitivity of 90.5% (95% CI, 80.9–95.8%) and specificity of 47.5% (95% CI, 34.5–60.8%) in detecting expert confirmed visualization of both ovaries. CONCLUSIONS: Our results suggest that, in a significant proportion of TVS annual screens, the sonographers may have mistaken other structures for normal ovaries. It is uncertain whether or not this affected the sensitivity and stage at detection of ovarian cancer in the ultrasound arm of UKCTOCS, but we conclude that QC metrics based on self‐reported visualization of normal ovaries are unreliable. The classifier shows some potential for addressing this problem, though further research is needed. © 2017 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology. John Wiley & Sons, Ltd. 2018-03-07 2018-03 /pmc/articles/PMC5888153/ /pubmed/28796383 http://dx.doi.org/10.1002/uog.18836 Text en © 2017 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of the International Society of Ultrasound in Obstetrics and Gynecology. This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Original Papers
Stott, W.
Campbell, S.
Franchini, A.
Blyuss, O.
Zaikin, A.
Ryan, A.
Jones, C.
Gentry‐Maharaj, A.
Fletcher, G.
Kalsi, J.
Skates, S.
Parmar, M.
Amso, N.
Jacobs, I.
Menon, U.
Sonographers' self‐reported visualization of normal postmenopausal ovaries on transvaginal ultrasound is not reliable: results of expert review of archived images from UKCTOCS
title Sonographers' self‐reported visualization of normal postmenopausal ovaries on transvaginal ultrasound is not reliable: results of expert review of archived images from UKCTOCS
title_full Sonographers' self‐reported visualization of normal postmenopausal ovaries on transvaginal ultrasound is not reliable: results of expert review of archived images from UKCTOCS
title_fullStr Sonographers' self‐reported visualization of normal postmenopausal ovaries on transvaginal ultrasound is not reliable: results of expert review of archived images from UKCTOCS
title_full_unstemmed Sonographers' self‐reported visualization of normal postmenopausal ovaries on transvaginal ultrasound is not reliable: results of expert review of archived images from UKCTOCS
title_short Sonographers' self‐reported visualization of normal postmenopausal ovaries on transvaginal ultrasound is not reliable: results of expert review of archived images from UKCTOCS
title_sort sonographers' self‐reported visualization of normal postmenopausal ovaries on transvaginal ultrasound is not reliable: results of expert review of archived images from ukctocs
topic Original Papers
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5888153/
https://www.ncbi.nlm.nih.gov/pubmed/28796383
http://dx.doi.org/10.1002/uog.18836
work_keys_str_mv AT stottw sonographersselfreportedvisualizationofnormalpostmenopausalovariesontransvaginalultrasoundisnotreliableresultsofexpertreviewofarchivedimagesfromukctocs
AT campbells sonographersselfreportedvisualizationofnormalpostmenopausalovariesontransvaginalultrasoundisnotreliableresultsofexpertreviewofarchivedimagesfromukctocs
AT franchinia sonographersselfreportedvisualizationofnormalpostmenopausalovariesontransvaginalultrasoundisnotreliableresultsofexpertreviewofarchivedimagesfromukctocs
AT blyusso sonographersselfreportedvisualizationofnormalpostmenopausalovariesontransvaginalultrasoundisnotreliableresultsofexpertreviewofarchivedimagesfromukctocs
AT zaikina sonographersselfreportedvisualizationofnormalpostmenopausalovariesontransvaginalultrasoundisnotreliableresultsofexpertreviewofarchivedimagesfromukctocs
AT ryana sonographersselfreportedvisualizationofnormalpostmenopausalovariesontransvaginalultrasoundisnotreliableresultsofexpertreviewofarchivedimagesfromukctocs
AT jonesc sonographersselfreportedvisualizationofnormalpostmenopausalovariesontransvaginalultrasoundisnotreliableresultsofexpertreviewofarchivedimagesfromukctocs
AT gentrymaharaja sonographersselfreportedvisualizationofnormalpostmenopausalovariesontransvaginalultrasoundisnotreliableresultsofexpertreviewofarchivedimagesfromukctocs
AT fletcherg sonographersselfreportedvisualizationofnormalpostmenopausalovariesontransvaginalultrasoundisnotreliableresultsofexpertreviewofarchivedimagesfromukctocs
AT kalsij sonographersselfreportedvisualizationofnormalpostmenopausalovariesontransvaginalultrasoundisnotreliableresultsofexpertreviewofarchivedimagesfromukctocs
AT skatess sonographersselfreportedvisualizationofnormalpostmenopausalovariesontransvaginalultrasoundisnotreliableresultsofexpertreviewofarchivedimagesfromukctocs
AT parmarm sonographersselfreportedvisualizationofnormalpostmenopausalovariesontransvaginalultrasoundisnotreliableresultsofexpertreviewofarchivedimagesfromukctocs
AT amson sonographersselfreportedvisualizationofnormalpostmenopausalovariesontransvaginalultrasoundisnotreliableresultsofexpertreviewofarchivedimagesfromukctocs
AT jacobsi sonographersselfreportedvisualizationofnormalpostmenopausalovariesontransvaginalultrasoundisnotreliableresultsofexpertreviewofarchivedimagesfromukctocs
AT menonu sonographersselfreportedvisualizationofnormalpostmenopausalovariesontransvaginalultrasoundisnotreliableresultsofexpertreviewofarchivedimagesfromukctocs