Cargando…
Clinical presentation of CIED infection following initial implant versus reoperation for generator change or lead addition
OBJECTIVE: To explore differences in clinical manifestations and outcomes in those patients who develop infection after undergoing initial implantation versus reoperation. METHODS: We compared cases of cardiac implantable electronic device (CIED) infection based on initial implantation versus reoper...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BMJ Publishing Group
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5888434/ https://www.ncbi.nlm.nih.gov/pubmed/29632673 http://dx.doi.org/10.1136/openhrt-2017-000681 |
_version_ | 1783312521427419136 |
---|---|
author | Harper, Mariko W Uslan, Daniel Z Greenspon, Arnold J Baddour, Larry M Carrillo, Roger G Danik, Stephan B Tolosana, Jose M Le, Katherine Miro, Jose M Naber, Christoph K Peacock, James Sohail, Muhammad Rizwan Vikram, Holenarasipur R Prutkin, Jordan M |
author_facet | Harper, Mariko W Uslan, Daniel Z Greenspon, Arnold J Baddour, Larry M Carrillo, Roger G Danik, Stephan B Tolosana, Jose M Le, Katherine Miro, Jose M Naber, Christoph K Peacock, James Sohail, Muhammad Rizwan Vikram, Holenarasipur R Prutkin, Jordan M |
author_sort | Harper, Mariko W |
collection | PubMed |
description | OBJECTIVE: To explore differences in clinical manifestations and outcomes in those patients who develop infection after undergoing initial implantation versus reoperation. METHODS: We compared cases of cardiac implantable electronic device (CIED) infection based on initial implantation versus reoperation from 11 centres. RESULTS: There were 432 patients with CIED infection, 178 occurring after initial device placement and 254 after repeat reoperation. No differences were seen in age, sex or device type. Those with infection after initial implant had a higher Charlson Comorbidity Score (median 3 (IQR 2–6) vs 2 (IQR 1–4), p<0.001), shorter time since last procedure (median 8.9 months (IQR 0.9–33.3) vs 19.5 months (IQR 1.1–62.9), p<0.0001) and fewer leads (2.0±0.6vs 2.5±0.9, p<0.001). Pocket infections were more likely to occur after a reoperation (70.1%vs48.9%, p<0.001) and coagulase negative staphylococci (CoNS) was the most frequently isolated organism in this group (p=0.029). In contrast, initial implant infections were more likely to present with higher white cell count (10.5±5.1 g/dL vs 9.5±5.4 g/dL, p=0.025), metastatic foci of infection (16.9%vs8.7%, p=0.016) and sepsis (30.9%vs19.3%, p=0.006). There were no differences in in-hospital (7.9%vs5.2%, p=0.31) or 6-month mortality (21.9%vs14.0%, p=0.056). CONCLUSIONS: CIED infections after initial device implant occur earlier, more aggressively, and often due to Staphylococcus aureus. In contrast, CIED infections after reoperation occur later, are due to CoNS, and have more indolent manifestations with primary localisation to the pocket. |
format | Online Article Text |
id | pubmed-5888434 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | BMJ Publishing Group |
record_format | MEDLINE/PubMed |
spelling | pubmed-58884342018-04-09 Clinical presentation of CIED infection following initial implant versus reoperation for generator change or lead addition Harper, Mariko W Uslan, Daniel Z Greenspon, Arnold J Baddour, Larry M Carrillo, Roger G Danik, Stephan B Tolosana, Jose M Le, Katherine Miro, Jose M Naber, Christoph K Peacock, James Sohail, Muhammad Rizwan Vikram, Holenarasipur R Prutkin, Jordan M Open Heart Arrhythmias and Sudden Death OBJECTIVE: To explore differences in clinical manifestations and outcomes in those patients who develop infection after undergoing initial implantation versus reoperation. METHODS: We compared cases of cardiac implantable electronic device (CIED) infection based on initial implantation versus reoperation from 11 centres. RESULTS: There were 432 patients with CIED infection, 178 occurring after initial device placement and 254 after repeat reoperation. No differences were seen in age, sex or device type. Those with infection after initial implant had a higher Charlson Comorbidity Score (median 3 (IQR 2–6) vs 2 (IQR 1–4), p<0.001), shorter time since last procedure (median 8.9 months (IQR 0.9–33.3) vs 19.5 months (IQR 1.1–62.9), p<0.0001) and fewer leads (2.0±0.6vs 2.5±0.9, p<0.001). Pocket infections were more likely to occur after a reoperation (70.1%vs48.9%, p<0.001) and coagulase negative staphylococci (CoNS) was the most frequently isolated organism in this group (p=0.029). In contrast, initial implant infections were more likely to present with higher white cell count (10.5±5.1 g/dL vs 9.5±5.4 g/dL, p=0.025), metastatic foci of infection (16.9%vs8.7%, p=0.016) and sepsis (30.9%vs19.3%, p=0.006). There were no differences in in-hospital (7.9%vs5.2%, p=0.31) or 6-month mortality (21.9%vs14.0%, p=0.056). CONCLUSIONS: CIED infections after initial device implant occur earlier, more aggressively, and often due to Staphylococcus aureus. In contrast, CIED infections after reoperation occur later, are due to CoNS, and have more indolent manifestations with primary localisation to the pocket. BMJ Publishing Group 2018-03-30 /pmc/articles/PMC5888434/ /pubmed/29632673 http://dx.doi.org/10.1136/openhrt-2017-000681 Text en © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted. This is an Open Access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ |
spellingShingle | Arrhythmias and Sudden Death Harper, Mariko W Uslan, Daniel Z Greenspon, Arnold J Baddour, Larry M Carrillo, Roger G Danik, Stephan B Tolosana, Jose M Le, Katherine Miro, Jose M Naber, Christoph K Peacock, James Sohail, Muhammad Rizwan Vikram, Holenarasipur R Prutkin, Jordan M Clinical presentation of CIED infection following initial implant versus reoperation for generator change or lead addition |
title | Clinical presentation of CIED infection following initial implant versus reoperation for generator change or lead addition |
title_full | Clinical presentation of CIED infection following initial implant versus reoperation for generator change or lead addition |
title_fullStr | Clinical presentation of CIED infection following initial implant versus reoperation for generator change or lead addition |
title_full_unstemmed | Clinical presentation of CIED infection following initial implant versus reoperation for generator change or lead addition |
title_short | Clinical presentation of CIED infection following initial implant versus reoperation for generator change or lead addition |
title_sort | clinical presentation of cied infection following initial implant versus reoperation for generator change or lead addition |
topic | Arrhythmias and Sudden Death |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5888434/ https://www.ncbi.nlm.nih.gov/pubmed/29632673 http://dx.doi.org/10.1136/openhrt-2017-000681 |
work_keys_str_mv | AT harpermarikow clinicalpresentationofciedinfectionfollowinginitialimplantversusreoperationforgeneratorchangeorleadaddition AT uslandanielz clinicalpresentationofciedinfectionfollowinginitialimplantversusreoperationforgeneratorchangeorleadaddition AT greensponarnoldj clinicalpresentationofciedinfectionfollowinginitialimplantversusreoperationforgeneratorchangeorleadaddition AT baddourlarrym clinicalpresentationofciedinfectionfollowinginitialimplantversusreoperationforgeneratorchangeorleadaddition AT carrillorogerg clinicalpresentationofciedinfectionfollowinginitialimplantversusreoperationforgeneratorchangeorleadaddition AT danikstephanb clinicalpresentationofciedinfectionfollowinginitialimplantversusreoperationforgeneratorchangeorleadaddition AT tolosanajosem clinicalpresentationofciedinfectionfollowinginitialimplantversusreoperationforgeneratorchangeorleadaddition AT lekatherine clinicalpresentationofciedinfectionfollowinginitialimplantversusreoperationforgeneratorchangeorleadaddition AT mirojosem clinicalpresentationofciedinfectionfollowinginitialimplantversusreoperationforgeneratorchangeorleadaddition AT naberchristophk clinicalpresentationofciedinfectionfollowinginitialimplantversusreoperationforgeneratorchangeorleadaddition AT peacockjames clinicalpresentationofciedinfectionfollowinginitialimplantversusreoperationforgeneratorchangeorleadaddition AT sohailmuhammadrizwan clinicalpresentationofciedinfectionfollowinginitialimplantversusreoperationforgeneratorchangeorleadaddition AT vikramholenarasipurr clinicalpresentationofciedinfectionfollowinginitialimplantversusreoperationforgeneratorchangeorleadaddition AT prutkinjordanm clinicalpresentationofciedinfectionfollowinginitialimplantversusreoperationforgeneratorchangeorleadaddition |