Cargando…

Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations

Patient-specific computational models are an established tool to support device development and test under clinically relevant boundary conditions. Potentially, such models could be used to aid the clinical decision-making process for percutaneous valve selection; however, their adoption in clinical...

Descripción completa

Detalles Bibliográficos
Autores principales: Bosi, Giorgia M., Capelli, Claudio, Cheang, Mun Hong, Delahunty, Nicola, Mullen, Michael, Taylor, Andrew M., Schievano, Silvia
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier Science 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5889787/
https://www.ncbi.nlm.nih.gov/pubmed/29482928
http://dx.doi.org/10.1016/j.jbiomech.2018.02.017
_version_ 1783312752248356864
author Bosi, Giorgia M.
Capelli, Claudio
Cheang, Mun Hong
Delahunty, Nicola
Mullen, Michael
Taylor, Andrew M.
Schievano, Silvia
author_facet Bosi, Giorgia M.
Capelli, Claudio
Cheang, Mun Hong
Delahunty, Nicola
Mullen, Michael
Taylor, Andrew M.
Schievano, Silvia
author_sort Bosi, Giorgia M.
collection PubMed
description Patient-specific computational models are an established tool to support device development and test under clinically relevant boundary conditions. Potentially, such models could be used to aid the clinical decision-making process for percutaneous valve selection; however, their adoption in clinical practice is still limited to individual cases. To be fully informative, they should include patient-specific data on both anatomy and mechanics of the implantation site. In this work, fourteen patient-specific computational models for transcatheter aortic valve replacement (TAVR) with balloon-expandable Sapien XT devices were retrospectively developed to tune the material parameters of the implantation site mechanical model for the average TAVR population. Pre-procedural computed tomography (CT) images were post-processed to create the 3D patient-specific anatomy of the implantation site. Balloon valvuloplasty and device deployment were simulated with finite element (FE) analysis. Valve leaflets and aortic root were modelled as linear elastic materials, while calcification as elastoplastic. Material properties were initially selected from literature; then, a statistical analysis was designed to investigate the effect of each implantation site material parameter on the implanted stent diameter and thus identify the combination of material parameters for TAVR patients. These numerical models were validated against clinical data. The comparison between stent diameters measured from post-procedural fluoroscopy images and final computational results showed a mean difference of 2.5 ± 3.9%. Moreover, the numerical model detected the presence of paravalvular leakage (PVL) in 79% of cases, as assessed by post-TAVR echocardiographic examination. The final aim was to increase accuracy and reliability of such computational tools for prospective clinical applications.
format Online
Article
Text
id pubmed-5889787
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Elsevier Science
record_format MEDLINE/PubMed
spelling pubmed-58897872018-04-11 Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations Bosi, Giorgia M. Capelli, Claudio Cheang, Mun Hong Delahunty, Nicola Mullen, Michael Taylor, Andrew M. Schievano, Silvia J Biomech Article Patient-specific computational models are an established tool to support device development and test under clinically relevant boundary conditions. Potentially, such models could be used to aid the clinical decision-making process for percutaneous valve selection; however, their adoption in clinical practice is still limited to individual cases. To be fully informative, they should include patient-specific data on both anatomy and mechanics of the implantation site. In this work, fourteen patient-specific computational models for transcatheter aortic valve replacement (TAVR) with balloon-expandable Sapien XT devices were retrospectively developed to tune the material parameters of the implantation site mechanical model for the average TAVR population. Pre-procedural computed tomography (CT) images were post-processed to create the 3D patient-specific anatomy of the implantation site. Balloon valvuloplasty and device deployment were simulated with finite element (FE) analysis. Valve leaflets and aortic root were modelled as linear elastic materials, while calcification as elastoplastic. Material properties were initially selected from literature; then, a statistical analysis was designed to investigate the effect of each implantation site material parameter on the implanted stent diameter and thus identify the combination of material parameters for TAVR patients. These numerical models were validated against clinical data. The comparison between stent diameters measured from post-procedural fluoroscopy images and final computational results showed a mean difference of 2.5 ± 3.9%. Moreover, the numerical model detected the presence of paravalvular leakage (PVL) in 79% of cases, as assessed by post-TAVR echocardiographic examination. The final aim was to increase accuracy and reliability of such computational tools for prospective clinical applications. Elsevier Science 2018-04-11 /pmc/articles/PMC5889787/ /pubmed/29482928 http://dx.doi.org/10.1016/j.jbiomech.2018.02.017 Text en © 2018 The Authors http://creativecommons.org/licenses/by/4.0/ This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Bosi, Giorgia M.
Capelli, Claudio
Cheang, Mun Hong
Delahunty, Nicola
Mullen, Michael
Taylor, Andrew M.
Schievano, Silvia
Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations
title Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations
title_full Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations
title_fullStr Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations
title_full_unstemmed Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations
title_short Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations
title_sort population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5889787/
https://www.ncbi.nlm.nih.gov/pubmed/29482928
http://dx.doi.org/10.1016/j.jbiomech.2018.02.017
work_keys_str_mv AT bosigiorgiam populationspecificmaterialpropertiesoftheimplantationsitefortranscatheteraorticvalvereplacementfiniteelementsimulations
AT capelliclaudio populationspecificmaterialpropertiesoftheimplantationsitefortranscatheteraorticvalvereplacementfiniteelementsimulations
AT cheangmunhong populationspecificmaterialpropertiesoftheimplantationsitefortranscatheteraorticvalvereplacementfiniteelementsimulations
AT delahuntynicola populationspecificmaterialpropertiesoftheimplantationsitefortranscatheteraorticvalvereplacementfiniteelementsimulations
AT mullenmichael populationspecificmaterialpropertiesoftheimplantationsitefortranscatheteraorticvalvereplacementfiniteelementsimulations
AT taylorandrewm populationspecificmaterialpropertiesoftheimplantationsitefortranscatheteraorticvalvereplacementfiniteelementsimulations
AT schievanosilvia populationspecificmaterialpropertiesoftheimplantationsitefortranscatheteraorticvalvereplacementfiniteelementsimulations