Cargando…
Automated Office Blood Pressure Measurement
Manual blood pressure (BP) recorded in routine clinical practice is relatively inaccurate and associated with higher readings compared to BP measured in research studies in accordance with standardized measurement guidelines. The increase in routine office BP is the result of several factors, especi...
Autor principal: | |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Cardiology
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5889975/ https://www.ncbi.nlm.nih.gov/pubmed/29625508 http://dx.doi.org/10.4070/kcj.2018.0066 |
_version_ | 1783312779026890752 |
---|---|
author | Myers, Martin G. |
author_facet | Myers, Martin G. |
author_sort | Myers, Martin G. |
collection | PubMed |
description | Manual blood pressure (BP) recorded in routine clinical practice is relatively inaccurate and associated with higher readings compared to BP measured in research studies in accordance with standardized measurement guidelines. The increase in routine office BP is the result of several factors, especially the presence of office staff, which tends to make patients nervous and also allows for conversation to occur. With the disappearance of the mercury sphygmomanometer because of environmental concerns, there is greater use of oscillometric BP recorders, both in the office setting and elsewhere. Although oscillometric devices may reduce some aspects of observer BP measurement error in the clinical setting, they are still associated with higher BP readings, known as white coat hypertension (for diagnosis) or white coat effect (with treated hypertension). Now that fully automated sphygmomanometers are available which are capable of recording several readings with the patient resting quietly, there is no longer any need to have office staff present when BP is being recorded. Such readings are called automated office blood pressure (AOBP) and they are both more accurate than conventional manual office BP and not associated with the white coat phenomena. AOBP readings are also similar to the awake ambulatory BP and home BP, both of which are relatively good predictors of cardiovascular risk. The available evidence suggests that AOBP should now replace manual or electronic office BP readings when screening patients for hypertension and also after antihypertensive drug therapy is initiated. |
format | Online Article Text |
id | pubmed-5889975 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Korean Society of Cardiology |
record_format | MEDLINE/PubMed |
spelling | pubmed-58899752018-04-12 Automated Office Blood Pressure Measurement Myers, Martin G. Korean Circ J Review Article Manual blood pressure (BP) recorded in routine clinical practice is relatively inaccurate and associated with higher readings compared to BP measured in research studies in accordance with standardized measurement guidelines. The increase in routine office BP is the result of several factors, especially the presence of office staff, which tends to make patients nervous and also allows for conversation to occur. With the disappearance of the mercury sphygmomanometer because of environmental concerns, there is greater use of oscillometric BP recorders, both in the office setting and elsewhere. Although oscillometric devices may reduce some aspects of observer BP measurement error in the clinical setting, they are still associated with higher BP readings, known as white coat hypertension (for diagnosis) or white coat effect (with treated hypertension). Now that fully automated sphygmomanometers are available which are capable of recording several readings with the patient resting quietly, there is no longer any need to have office staff present when BP is being recorded. Such readings are called automated office blood pressure (AOBP) and they are both more accurate than conventional manual office BP and not associated with the white coat phenomena. AOBP readings are also similar to the awake ambulatory BP and home BP, both of which are relatively good predictors of cardiovascular risk. The available evidence suggests that AOBP should now replace manual or electronic office BP readings when screening patients for hypertension and also after antihypertensive drug therapy is initiated. The Korean Society of Cardiology 2018-03-23 /pmc/articles/PMC5889975/ /pubmed/29625508 http://dx.doi.org/10.4070/kcj.2018.0066 Text en Copyright © 2018. The Korean Society of Cardiology https://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Review Article Myers, Martin G. Automated Office Blood Pressure Measurement |
title | Automated Office Blood Pressure Measurement |
title_full | Automated Office Blood Pressure Measurement |
title_fullStr | Automated Office Blood Pressure Measurement |
title_full_unstemmed | Automated Office Blood Pressure Measurement |
title_short | Automated Office Blood Pressure Measurement |
title_sort | automated office blood pressure measurement |
topic | Review Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5889975/ https://www.ncbi.nlm.nih.gov/pubmed/29625508 http://dx.doi.org/10.4070/kcj.2018.0066 |
work_keys_str_mv | AT myersmarting automatedofficebloodpressuremeasurement |