Cargando…

Automated Office Blood Pressure Measurement

Manual blood pressure (BP) recorded in routine clinical practice is relatively inaccurate and associated with higher readings compared to BP measured in research studies in accordance with standardized measurement guidelines. The increase in routine office BP is the result of several factors, especi...

Descripción completa

Detalles Bibliográficos
Autor principal: Myers, Martin G.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Korean Society of Cardiology 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5889975/
https://www.ncbi.nlm.nih.gov/pubmed/29625508
http://dx.doi.org/10.4070/kcj.2018.0066
_version_ 1783312779026890752
author Myers, Martin G.
author_facet Myers, Martin G.
author_sort Myers, Martin G.
collection PubMed
description Manual blood pressure (BP) recorded in routine clinical practice is relatively inaccurate and associated with higher readings compared to BP measured in research studies in accordance with standardized measurement guidelines. The increase in routine office BP is the result of several factors, especially the presence of office staff, which tends to make patients nervous and also allows for conversation to occur. With the disappearance of the mercury sphygmomanometer because of environmental concerns, there is greater use of oscillometric BP recorders, both in the office setting and elsewhere. Although oscillometric devices may reduce some aspects of observer BP measurement error in the clinical setting, they are still associated with higher BP readings, known as white coat hypertension (for diagnosis) or white coat effect (with treated hypertension). Now that fully automated sphygmomanometers are available which are capable of recording several readings with the patient resting quietly, there is no longer any need to have office staff present when BP is being recorded. Such readings are called automated office blood pressure (AOBP) and they are both more accurate than conventional manual office BP and not associated with the white coat phenomena. AOBP readings are also similar to the awake ambulatory BP and home BP, both of which are relatively good predictors of cardiovascular risk. The available evidence suggests that AOBP should now replace manual or electronic office BP readings when screening patients for hypertension and also after antihypertensive drug therapy is initiated.
format Online
Article
Text
id pubmed-5889975
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher The Korean Society of Cardiology
record_format MEDLINE/PubMed
spelling pubmed-58899752018-04-12 Automated Office Blood Pressure Measurement Myers, Martin G. Korean Circ J Review Article Manual blood pressure (BP) recorded in routine clinical practice is relatively inaccurate and associated with higher readings compared to BP measured in research studies in accordance with standardized measurement guidelines. The increase in routine office BP is the result of several factors, especially the presence of office staff, which tends to make patients nervous and also allows for conversation to occur. With the disappearance of the mercury sphygmomanometer because of environmental concerns, there is greater use of oscillometric BP recorders, both in the office setting and elsewhere. Although oscillometric devices may reduce some aspects of observer BP measurement error in the clinical setting, they are still associated with higher BP readings, known as white coat hypertension (for diagnosis) or white coat effect (with treated hypertension). Now that fully automated sphygmomanometers are available which are capable of recording several readings with the patient resting quietly, there is no longer any need to have office staff present when BP is being recorded. Such readings are called automated office blood pressure (AOBP) and they are both more accurate than conventional manual office BP and not associated with the white coat phenomena. AOBP readings are also similar to the awake ambulatory BP and home BP, both of which are relatively good predictors of cardiovascular risk. The available evidence suggests that AOBP should now replace manual or electronic office BP readings when screening patients for hypertension and also after antihypertensive drug therapy is initiated. The Korean Society of Cardiology 2018-03-23 /pmc/articles/PMC5889975/ /pubmed/29625508 http://dx.doi.org/10.4070/kcj.2018.0066 Text en Copyright © 2018. The Korean Society of Cardiology https://creativecommons.org/licenses/by-nc/4.0 This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (https://creativecommons.org/licenses/by-nc/4.0) which permits unrestricted noncommercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Review Article
Myers, Martin G.
Automated Office Blood Pressure Measurement
title Automated Office Blood Pressure Measurement
title_full Automated Office Blood Pressure Measurement
title_fullStr Automated Office Blood Pressure Measurement
title_full_unstemmed Automated Office Blood Pressure Measurement
title_short Automated Office Blood Pressure Measurement
title_sort automated office blood pressure measurement
topic Review Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5889975/
https://www.ncbi.nlm.nih.gov/pubmed/29625508
http://dx.doi.org/10.4070/kcj.2018.0066
work_keys_str_mv AT myersmarting automatedofficebloodpressuremeasurement