The influence of implant–abutment connection on the screw loosening and microleakage

BACKGROUND: There are some spaces between abutment and implant body which can be a reservoir of toxic substance, and they can penetrate into subgingival space from microgap at the implant–abutment interface. This penetration may cause periimplantitis which is known to be one of the most important fa...

Descripción completa

Detalles Bibliográficos
Autores principales: Tsuruta, Katsuhiro, Ayukawa, Yasunori, Matsuzaki, Tatsuya, Kihara, Masafumi, Koyano, Kiyoshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5890007/
https://www.ncbi.nlm.nih.gov/pubmed/29629492
http://dx.doi.org/10.1186/s40729-018-0121-y
_version_ 1783312786544132096
author Tsuruta, Katsuhiro
Ayukawa, Yasunori
Matsuzaki, Tatsuya
Kihara, Masafumi
Koyano, Kiyoshi
author_facet Tsuruta, Katsuhiro
Ayukawa, Yasunori
Matsuzaki, Tatsuya
Kihara, Masafumi
Koyano, Kiyoshi
author_sort Tsuruta, Katsuhiro
collection PubMed
description BACKGROUND: There are some spaces between abutment and implant body which can be a reservoir of toxic substance, and they can penetrate into subgingival space from microgap at the implant–abutment interface. This penetration may cause periimplantitis which is known to be one of the most important factors associated with late failure. In the present study, three kinds of abutment connection system, external parallel connection (EP), internal parallel connection (IP), and internal conical connection (CC), were studied from the viewpoint of microleakage from the gap between the implant and the abutment and in connection with the loosening of abutment screw. METHODS: We observed dye leakage from abutment screw hole to outside through microgap under the excessive compressive and tensile load and evaluated the anti-leakage characteristics of these connection systems. RESULTS: During the experiment, one abutment screw for EP and two screws for IP, out of seven samples in each group, were fractured. After the 2000 cycles of compressive tensile loadings, removal torque value (RTV) of abutment screw represented no statistical differences among three groups. Standard deviation was largest in the RTV of EP and smallest in that of CC. The results of microleakage of toluidine blue from implant–abutment connection indicated that microleakage generally increased as loading procedure progressed. The amount of microleakage was almost plateau at 2000 cycles in CC, but still increasing in other two groups. The value of microleakage greatly scattered in EP, but the deviation of that in CC is significantly smaller. At 500 cycles of loading, there were no significant differences in the amount of microleakage among the groups, but at 1000, 1500, and 2000 cycles of loading, the amount of microleakage in CC was significantly smaller than that in IP. Throughout the experiment, the amount of microleakage in EP was largest, but no statistical difference was indicated due to the high standard deviation. CONCLUSIONS: Within the limitation of the present study, CC was stable even after the loading in the RTV of abutment screw and it prevented microleakage from the microgap between the implant body and the abutment, among the three tested connections.
format Online
Article
Text
id pubmed-5890007
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-58900072018-04-17 The influence of implant–abutment connection on the screw loosening and microleakage Tsuruta, Katsuhiro Ayukawa, Yasunori Matsuzaki, Tatsuya Kihara, Masafumi Koyano, Kiyoshi Int J Implant Dent Research BACKGROUND: There are some spaces between abutment and implant body which can be a reservoir of toxic substance, and they can penetrate into subgingival space from microgap at the implant–abutment interface. This penetration may cause periimplantitis which is known to be one of the most important factors associated with late failure. In the present study, three kinds of abutment connection system, external parallel connection (EP), internal parallel connection (IP), and internal conical connection (CC), were studied from the viewpoint of microleakage from the gap between the implant and the abutment and in connection with the loosening of abutment screw. METHODS: We observed dye leakage from abutment screw hole to outside through microgap under the excessive compressive and tensile load and evaluated the anti-leakage characteristics of these connection systems. RESULTS: During the experiment, one abutment screw for EP and two screws for IP, out of seven samples in each group, were fractured. After the 2000 cycles of compressive tensile loadings, removal torque value (RTV) of abutment screw represented no statistical differences among three groups. Standard deviation was largest in the RTV of EP and smallest in that of CC. The results of microleakage of toluidine blue from implant–abutment connection indicated that microleakage generally increased as loading procedure progressed. The amount of microleakage was almost plateau at 2000 cycles in CC, but still increasing in other two groups. The value of microleakage greatly scattered in EP, but the deviation of that in CC is significantly smaller. At 500 cycles of loading, there were no significant differences in the amount of microleakage among the groups, but at 1000, 1500, and 2000 cycles of loading, the amount of microleakage in CC was significantly smaller than that in IP. Throughout the experiment, the amount of microleakage in EP was largest, but no statistical difference was indicated due to the high standard deviation. CONCLUSIONS: Within the limitation of the present study, CC was stable even after the loading in the RTV of abutment screw and it prevented microleakage from the microgap between the implant body and the abutment, among the three tested connections. Springer Berlin Heidelberg 2018-04-09 /pmc/articles/PMC5890007/ /pubmed/29629492 http://dx.doi.org/10.1186/s40729-018-0121-y Text en © The Author(s). 2018 Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
spellingShingle Research
Tsuruta, Katsuhiro
Ayukawa, Yasunori
Matsuzaki, Tatsuya
Kihara, Masafumi
Koyano, Kiyoshi
The influence of implant–abutment connection on the screw loosening and microleakage
title The influence of implant–abutment connection on the screw loosening and microleakage
title_full The influence of implant–abutment connection on the screw loosening and microleakage
title_fullStr The influence of implant–abutment connection on the screw loosening and microleakage
title_full_unstemmed The influence of implant–abutment connection on the screw loosening and microleakage
title_short The influence of implant–abutment connection on the screw loosening and microleakage
title_sort influence of implant–abutment connection on the screw loosening and microleakage
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5890007/
https://www.ncbi.nlm.nih.gov/pubmed/29629492
http://dx.doi.org/10.1186/s40729-018-0121-y
work_keys_str_mv AT tsurutakatsuhiro theinfluenceofimplantabutmentconnectiononthescrewlooseningandmicroleakage
AT ayukawayasunori theinfluenceofimplantabutmentconnectiononthescrewlooseningandmicroleakage
AT matsuzakitatsuya theinfluenceofimplantabutmentconnectiononthescrewlooseningandmicroleakage
AT kiharamasafumi theinfluenceofimplantabutmentconnectiononthescrewlooseningandmicroleakage
AT koyanokiyoshi theinfluenceofimplantabutmentconnectiononthescrewlooseningandmicroleakage
AT tsurutakatsuhiro influenceofimplantabutmentconnectiononthescrewlooseningandmicroleakage
AT ayukawayasunori influenceofimplantabutmentconnectiononthescrewlooseningandmicroleakage
AT matsuzakitatsuya influenceofimplantabutmentconnectiononthescrewlooseningandmicroleakage
AT kiharamasafumi influenceofimplantabutmentconnectiononthescrewlooseningandmicroleakage
AT koyanokiyoshi influenceofimplantabutmentconnectiononthescrewlooseningandmicroleakage