Cargando…
Performance of the TB-LAMP diagnostic assay in reference laboratories: Results from a multicentre study
OBJECTIVE: To evaluate the diagnostic performance of TB-LAMP, a manual molecular tuberculosis (TB) detection method, and provide comparison to the Xpert MTB/RIF assay. METHODS: In a large multicentre study, two sputum samples were collected from participants with TB symptoms in reference laboratorie...
Autores principales: | , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Author(s). Published by Elsevier Ltd on behalf of International Society for Infectious Diseases.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5890091/ https://www.ncbi.nlm.nih.gov/pubmed/29410366 http://dx.doi.org/10.1016/j.ijid.2018.01.005 |
_version_ | 1783312800227000320 |
---|---|
author | Pham, Thu Hang Peter, Jonathan Mello, Fernanda C.Q. Parraga, Tommy Lan, Nguyen Thi Ngoc Nabeta, Pamela Valli, Eloise Caceres, Tatiana Dheda, Keertan Dorman, Susan E. Hillemann, Doris Gray, Christen M. Perkins, Mark D. |
author_facet | Pham, Thu Hang Peter, Jonathan Mello, Fernanda C.Q. Parraga, Tommy Lan, Nguyen Thi Ngoc Nabeta, Pamela Valli, Eloise Caceres, Tatiana Dheda, Keertan Dorman, Susan E. Hillemann, Doris Gray, Christen M. Perkins, Mark D. |
author_sort | Pham, Thu Hang |
collection | PubMed |
description | OBJECTIVE: To evaluate the diagnostic performance of TB-LAMP, a manual molecular tuberculosis (TB) detection method, and provide comparison to the Xpert MTB/RIF assay. METHODS: In a large multicentre study, two sputum samples were collected from participants with TB symptoms in reference laboratories in Peru, South Africa, Brazil, and Vietnam. Each sample was tested with TB-LAMP. The reference standard consisted of four direct smears, four cultures, and clinical and radiological findings. Individuals negative on conventional tests were followed up after 8 weeks. The Xpert MTB/RIF assay was performed on fresh or frozen samples as a molecular test comparison. RESULTS: A total of 1036 adults with suspected TB were enrolled. Among 375 culture-confirmed TB cases with 750 sputum samples, TB-LAMP detected 75.6% (95% confidence interval (CI) 71.8–79.4%), including 97.9% (95% CI 96.4–99.4%) of smear-positive TB samples and 46.6% (95% CI 40.6–52.7%) of smear-negative TB samples. Specificity in 477 culture-negative participants not treated for TB (954 sputum samples) was 98.7% (95% CI 97.9–99.6%). TB-LAMP test results were indeterminate in 0.3% of cases. CONCLUSIONS: TB-LAMP detects nearly all smear-positive and half of smear-negative TB cases and has a high specificity when performed in reference laboratories. Performance was similar to the Xpert MTB/RIF assay. |
format | Online Article Text |
id | pubmed-5890091 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Author(s). Published by Elsevier Ltd on behalf of International Society for Infectious Diseases. |
record_format | MEDLINE/PubMed |
spelling | pubmed-58900912018-04-10 Performance of the TB-LAMP diagnostic assay in reference laboratories: Results from a multicentre study Pham, Thu Hang Peter, Jonathan Mello, Fernanda C.Q. Parraga, Tommy Lan, Nguyen Thi Ngoc Nabeta, Pamela Valli, Eloise Caceres, Tatiana Dheda, Keertan Dorman, Susan E. Hillemann, Doris Gray, Christen M. Perkins, Mark D. Int J Infect Dis Article OBJECTIVE: To evaluate the diagnostic performance of TB-LAMP, a manual molecular tuberculosis (TB) detection method, and provide comparison to the Xpert MTB/RIF assay. METHODS: In a large multicentre study, two sputum samples were collected from participants with TB symptoms in reference laboratories in Peru, South Africa, Brazil, and Vietnam. Each sample was tested with TB-LAMP. The reference standard consisted of four direct smears, four cultures, and clinical and radiological findings. Individuals negative on conventional tests were followed up after 8 weeks. The Xpert MTB/RIF assay was performed on fresh or frozen samples as a molecular test comparison. RESULTS: A total of 1036 adults with suspected TB were enrolled. Among 375 culture-confirmed TB cases with 750 sputum samples, TB-LAMP detected 75.6% (95% confidence interval (CI) 71.8–79.4%), including 97.9% (95% CI 96.4–99.4%) of smear-positive TB samples and 46.6% (95% CI 40.6–52.7%) of smear-negative TB samples. Specificity in 477 culture-negative participants not treated for TB (954 sputum samples) was 98.7% (95% CI 97.9–99.6%). TB-LAMP test results were indeterminate in 0.3% of cases. CONCLUSIONS: TB-LAMP detects nearly all smear-positive and half of smear-negative TB cases and has a high specificity when performed in reference laboratories. Performance was similar to the Xpert MTB/RIF assay. The Author(s). Published by Elsevier Ltd on behalf of International Society for Infectious Diseases. 2018-03 2018-02-02 /pmc/articles/PMC5890091/ /pubmed/29410366 http://dx.doi.org/10.1016/j.ijid.2018.01.005 Text en © 2018 The Author(s) Since January 2020 Elsevier has created a COVID-19 resource centre with free information in English and Mandarin on the novel coronavirus COVID-19. The COVID-19 resource centre is hosted on Elsevier Connect, the company's public news and information website. Elsevier hereby grants permission to make all its COVID-19-related research that is available on the COVID-19 resource centre - including this research content - immediately available in PubMed Central and other publicly funded repositories, such as the WHO COVID database with rights for unrestricted research re-use and analyses in any form or by any means with acknowledgement of the original source. These permissions are granted for free by Elsevier for as long as the COVID-19 resource centre remains active. |
spellingShingle | Article Pham, Thu Hang Peter, Jonathan Mello, Fernanda C.Q. Parraga, Tommy Lan, Nguyen Thi Ngoc Nabeta, Pamela Valli, Eloise Caceres, Tatiana Dheda, Keertan Dorman, Susan E. Hillemann, Doris Gray, Christen M. Perkins, Mark D. Performance of the TB-LAMP diagnostic assay in reference laboratories: Results from a multicentre study |
title | Performance of the TB-LAMP diagnostic assay in reference laboratories: Results from a multicentre study |
title_full | Performance of the TB-LAMP diagnostic assay in reference laboratories: Results from a multicentre study |
title_fullStr | Performance of the TB-LAMP diagnostic assay in reference laboratories: Results from a multicentre study |
title_full_unstemmed | Performance of the TB-LAMP diagnostic assay in reference laboratories: Results from a multicentre study |
title_short | Performance of the TB-LAMP diagnostic assay in reference laboratories: Results from a multicentre study |
title_sort | performance of the tb-lamp diagnostic assay in reference laboratories: results from a multicentre study |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5890091/ https://www.ncbi.nlm.nih.gov/pubmed/29410366 http://dx.doi.org/10.1016/j.ijid.2018.01.005 |
work_keys_str_mv | AT phamthuhang performanceofthetblampdiagnosticassayinreferencelaboratoriesresultsfromamulticentrestudy AT peterjonathan performanceofthetblampdiagnosticassayinreferencelaboratoriesresultsfromamulticentrestudy AT mellofernandacq performanceofthetblampdiagnosticassayinreferencelaboratoriesresultsfromamulticentrestudy AT parragatommy performanceofthetblampdiagnosticassayinreferencelaboratoriesresultsfromamulticentrestudy AT lannguyenthingoc performanceofthetblampdiagnosticassayinreferencelaboratoriesresultsfromamulticentrestudy AT nabetapamela performanceofthetblampdiagnosticassayinreferencelaboratoriesresultsfromamulticentrestudy AT vallieloise performanceofthetblampdiagnosticassayinreferencelaboratoriesresultsfromamulticentrestudy AT cacerestatiana performanceofthetblampdiagnosticassayinreferencelaboratoriesresultsfromamulticentrestudy AT dhedakeertan performanceofthetblampdiagnosticassayinreferencelaboratoriesresultsfromamulticentrestudy AT dormansusane performanceofthetblampdiagnosticassayinreferencelaboratoriesresultsfromamulticentrestudy AT hillemanndoris performanceofthetblampdiagnosticassayinreferencelaboratoriesresultsfromamulticentrestudy AT graychristenm performanceofthetblampdiagnosticassayinreferencelaboratoriesresultsfromamulticentrestudy AT perkinsmarkd performanceofthetblampdiagnosticassayinreferencelaboratoriesresultsfromamulticentrestudy |