Is it possible to reduce intra-hospital transport time for computed tomography evaluation in critically ill cases using the Easy Tube Arrange Device?
OBJECTIVE: Patients are often transported within the hospital, especially in cases of critical illness for which computed tomography (CT) is performed. Since increased transport time increases the risks of complications, reducing transport time is important for patient safety. This study aimed to ev...
Autores principales: | , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Korean Society of Emergency Medicine
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5891741/ https://www.ncbi.nlm.nih.gov/pubmed/29618188 http://dx.doi.org/10.15441/ceem.16.183 |
_version_ | 1783313051719565312 |
---|---|
author | Song, Kyung Hyeok Cho, Sung Uk Lee, Jin Woong Cho, Yong Chul Jeong, Won Joon You, Yeon Ho Ryu, Seung Kim, Seung Whan Yoo, In Sool Joo, Ki Hyuk |
author_facet | Song, Kyung Hyeok Cho, Sung Uk Lee, Jin Woong Cho, Yong Chul Jeong, Won Joon You, Yeon Ho Ryu, Seung Kim, Seung Whan Yoo, In Sool Joo, Ki Hyuk |
author_sort | Song, Kyung Hyeok |
collection | PubMed |
description | OBJECTIVE: Patients are often transported within the hospital, especially in cases of critical illness for which computed tomography (CT) is performed. Since increased transport time increases the risks of complications, reducing transport time is important for patient safety. This study aimed to evaluate the ability of our newly invented device, the Easy Tube Arrange Device (ETAD), to reduce transport time for CT evaluation in cases of critical illness. METHODS: This prospective randomized control study included 60 volunteers. Each participant arranged five or six intravenous fluid lines, monitoring lines (noninvasive blood pressure, electrocardiography, central venous pressure, arterial catheter), and therapeutic equipment (O2 supply device, Foley catheter) on a Resusci Anne mannequin. We measured transport time for the CT evaluation by using conventional and ETAD method. RESULTS: The median transport time for CT evaluation was 488.50 seconds (95% confidence interval [CI], 462.75 to 514.75) and, 503.50 seconds (95% CI, 489.50 to 526.75) with 5 and 6 fluid lines using the conventional method and 364.50 seconds (95% CI, 335.00 to 388.75), and 363.50 seconds (95% CI, 331.75 to 377.75) with ETAD (all P<0.001). The time differences were 131.50 (95% CI, 89.25 to 174.50) and 148.00 (95% CI, 116.00 to 177.75) (all P<0.001). CONCLUSION: The transport time for CT evaluation was reduced using the ETAD, which would be expected to reduce the complications that may occur during transport in cases of critical illness. |
format | Online Article Text |
id | pubmed-5891741 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | The Korean Society of Emergency Medicine |
record_format | MEDLINE/PubMed |
spelling | pubmed-58917412018-04-11 Is it possible to reduce intra-hospital transport time for computed tomography evaluation in critically ill cases using the Easy Tube Arrange Device? Song, Kyung Hyeok Cho, Sung Uk Lee, Jin Woong Cho, Yong Chul Jeong, Won Joon You, Yeon Ho Ryu, Seung Kim, Seung Whan Yoo, In Sool Joo, Ki Hyuk Clin Exp Emerg Med Original Article OBJECTIVE: Patients are often transported within the hospital, especially in cases of critical illness for which computed tomography (CT) is performed. Since increased transport time increases the risks of complications, reducing transport time is important for patient safety. This study aimed to evaluate the ability of our newly invented device, the Easy Tube Arrange Device (ETAD), to reduce transport time for CT evaluation in cases of critical illness. METHODS: This prospective randomized control study included 60 volunteers. Each participant arranged five or six intravenous fluid lines, monitoring lines (noninvasive blood pressure, electrocardiography, central venous pressure, arterial catheter), and therapeutic equipment (O2 supply device, Foley catheter) on a Resusci Anne mannequin. We measured transport time for the CT evaluation by using conventional and ETAD method. RESULTS: The median transport time for CT evaluation was 488.50 seconds (95% confidence interval [CI], 462.75 to 514.75) and, 503.50 seconds (95% CI, 489.50 to 526.75) with 5 and 6 fluid lines using the conventional method and 364.50 seconds (95% CI, 335.00 to 388.75), and 363.50 seconds (95% CI, 331.75 to 377.75) with ETAD (all P<0.001). The time differences were 131.50 (95% CI, 89.25 to 174.50) and 148.00 (95% CI, 116.00 to 177.75) (all P<0.001). CONCLUSION: The transport time for CT evaluation was reduced using the ETAD, which would be expected to reduce the complications that may occur during transport in cases of critical illness. The Korean Society of Emergency Medicine 2018-03-30 /pmc/articles/PMC5891741/ /pubmed/29618188 http://dx.doi.org/10.15441/ceem.16.183 Text en Copyright © 2018 The Korean Society of Emergency Medicine This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/). |
spellingShingle | Original Article Song, Kyung Hyeok Cho, Sung Uk Lee, Jin Woong Cho, Yong Chul Jeong, Won Joon You, Yeon Ho Ryu, Seung Kim, Seung Whan Yoo, In Sool Joo, Ki Hyuk Is it possible to reduce intra-hospital transport time for computed tomography evaluation in critically ill cases using the Easy Tube Arrange Device? |
title | Is it possible to reduce intra-hospital transport time for computed tomography evaluation in critically ill cases using the Easy Tube Arrange Device? |
title_full | Is it possible to reduce intra-hospital transport time for computed tomography evaluation in critically ill cases using the Easy Tube Arrange Device? |
title_fullStr | Is it possible to reduce intra-hospital transport time for computed tomography evaluation in critically ill cases using the Easy Tube Arrange Device? |
title_full_unstemmed | Is it possible to reduce intra-hospital transport time for computed tomography evaluation in critically ill cases using the Easy Tube Arrange Device? |
title_short | Is it possible to reduce intra-hospital transport time for computed tomography evaluation in critically ill cases using the Easy Tube Arrange Device? |
title_sort | is it possible to reduce intra-hospital transport time for computed tomography evaluation in critically ill cases using the easy tube arrange device? |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5891741/ https://www.ncbi.nlm.nih.gov/pubmed/29618188 http://dx.doi.org/10.15441/ceem.16.183 |
work_keys_str_mv | AT songkyunghyeok isitpossibletoreduceintrahospitaltransporttimeforcomputedtomographyevaluationincriticallyillcasesusingtheeasytubearrangedevice AT chosunguk isitpossibletoreduceintrahospitaltransporttimeforcomputedtomographyevaluationincriticallyillcasesusingtheeasytubearrangedevice AT leejinwoong isitpossibletoreduceintrahospitaltransporttimeforcomputedtomographyevaluationincriticallyillcasesusingtheeasytubearrangedevice AT choyongchul isitpossibletoreduceintrahospitaltransporttimeforcomputedtomographyevaluationincriticallyillcasesusingtheeasytubearrangedevice AT jeongwonjoon isitpossibletoreduceintrahospitaltransporttimeforcomputedtomographyevaluationincriticallyillcasesusingtheeasytubearrangedevice AT youyeonho isitpossibletoreduceintrahospitaltransporttimeforcomputedtomographyevaluationincriticallyillcasesusingtheeasytubearrangedevice AT ryuseung isitpossibletoreduceintrahospitaltransporttimeforcomputedtomographyevaluationincriticallyillcasesusingtheeasytubearrangedevice AT kimseungwhan isitpossibletoreduceintrahospitaltransporttimeforcomputedtomographyevaluationincriticallyillcasesusingtheeasytubearrangedevice AT yooinsool isitpossibletoreduceintrahospitaltransporttimeforcomputedtomographyevaluationincriticallyillcasesusingtheeasytubearrangedevice AT jookihyuk isitpossibletoreduceintrahospitaltransporttimeforcomputedtomographyevaluationincriticallyillcasesusingtheeasytubearrangedevice |