Cargando…
A Retrospective Study to Compare the Use of the Mean Apnea-Hypopnea Duration and the Apnea-Hypopnea Index with Blood Oxygenation and Sleep Patterns in Patients with Obstructive Sleep Apnea Diagnosed by Polysomnography
BACKGROUND: The apnea-hypopnea index (AHI) and the mean apnea-hypopnea duration (MAD) are used to measure the severity of the symptoms of obstructive sleep apnea (OSA). The aim of this study was to compare the use of the MAD with the AHI as indicators of clinical and demographic parameters, blood ox...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Scientific Literature, Inc.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5892846/ https://www.ncbi.nlm.nih.gov/pubmed/29603712 http://dx.doi.org/10.12659/MSM.909219 |
_version_ | 1783313217747943424 |
---|---|
author | Zhan, Xiaojun Fang, Fang Wu, Chan Pinto, Jayant M. Wei, Yongxiang |
author_facet | Zhan, Xiaojun Fang, Fang Wu, Chan Pinto, Jayant M. Wei, Yongxiang |
author_sort | Zhan, Xiaojun |
collection | PubMed |
description | BACKGROUND: The apnea-hypopnea index (AHI) and the mean apnea-hypopnea duration (MAD) are used to measure the severity of the symptoms of obstructive sleep apnea (OSA). The aim of this study was to compare the use of the MAD with the AHI as indicators of clinical and demographic parameters, blood oxygenation, and sleep parameters in patients diagnosed with OSA by polysomnography (PSG). MATERIAL/METHODS: A retrospective study included 511 patients with OSA diagnosed by PSG and who had the AHI and the MAD measured according to the guidelines from the American Academy of Sleep Medicine (AASM). The patients were divided into two groups: patients with a short MAD and with a long MAD, according to median duration, and using the inter-quartile range (IQR), as the data were not normally distributed. Clinical and demographic parameters were recorded. Pulse oximetry was used to measure blood oxygen saturation during sleep, sleep structure was recorded, and the Epworth Sleepiness Scale (ESS) questionnaire was used to measure daytime sleepiness. RESULTS: In all 511 patients with OSA, the MAD was significantly, but weakly, correlated with the AHI (r=0.17, P<0.01), but showed no significant associations with patient age (r=0.08, P=0.06), body weight (r=0.014, P=0.75), and height (r=0.06, P=0.16). Patients with a long MAD or severe OSA (n=260) had significantly worse blood oxygen levels and sleep parameters. CONCLUSIONS: For patients with severe OSA, this study showed that the MAD was a useful indicator of blood oxygenation and sleep parameters. |
format | Online Article Text |
id | pubmed-5892846 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | International Scientific Literature, Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-58928462018-04-18 A Retrospective Study to Compare the Use of the Mean Apnea-Hypopnea Duration and the Apnea-Hypopnea Index with Blood Oxygenation and Sleep Patterns in Patients with Obstructive Sleep Apnea Diagnosed by Polysomnography Zhan, Xiaojun Fang, Fang Wu, Chan Pinto, Jayant M. Wei, Yongxiang Med Sci Monit Clinical Research BACKGROUND: The apnea-hypopnea index (AHI) and the mean apnea-hypopnea duration (MAD) are used to measure the severity of the symptoms of obstructive sleep apnea (OSA). The aim of this study was to compare the use of the MAD with the AHI as indicators of clinical and demographic parameters, blood oxygenation, and sleep parameters in patients diagnosed with OSA by polysomnography (PSG). MATERIAL/METHODS: A retrospective study included 511 patients with OSA diagnosed by PSG and who had the AHI and the MAD measured according to the guidelines from the American Academy of Sleep Medicine (AASM). The patients were divided into two groups: patients with a short MAD and with a long MAD, according to median duration, and using the inter-quartile range (IQR), as the data were not normally distributed. Clinical and demographic parameters were recorded. Pulse oximetry was used to measure blood oxygen saturation during sleep, sleep structure was recorded, and the Epworth Sleepiness Scale (ESS) questionnaire was used to measure daytime sleepiness. RESULTS: In all 511 patients with OSA, the MAD was significantly, but weakly, correlated with the AHI (r=0.17, P<0.01), but showed no significant associations with patient age (r=0.08, P=0.06), body weight (r=0.014, P=0.75), and height (r=0.06, P=0.16). Patients with a long MAD or severe OSA (n=260) had significantly worse blood oxygen levels and sleep parameters. CONCLUSIONS: For patients with severe OSA, this study showed that the MAD was a useful indicator of blood oxygenation and sleep parameters. International Scientific Literature, Inc. 2018-03-31 /pmc/articles/PMC5892846/ /pubmed/29603712 http://dx.doi.org/10.12659/MSM.909219 Text en © Med Sci Monit, 2018 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) ) |
spellingShingle | Clinical Research Zhan, Xiaojun Fang, Fang Wu, Chan Pinto, Jayant M. Wei, Yongxiang A Retrospective Study to Compare the Use of the Mean Apnea-Hypopnea Duration and the Apnea-Hypopnea Index with Blood Oxygenation and Sleep Patterns in Patients with Obstructive Sleep Apnea Diagnosed by Polysomnography |
title | A Retrospective Study to Compare the Use of the Mean Apnea-Hypopnea Duration and the Apnea-Hypopnea Index with Blood Oxygenation and Sleep Patterns in Patients with Obstructive Sleep Apnea Diagnosed by Polysomnography |
title_full | A Retrospective Study to Compare the Use of the Mean Apnea-Hypopnea Duration and the Apnea-Hypopnea Index with Blood Oxygenation and Sleep Patterns in Patients with Obstructive Sleep Apnea Diagnosed by Polysomnography |
title_fullStr | A Retrospective Study to Compare the Use of the Mean Apnea-Hypopnea Duration and the Apnea-Hypopnea Index with Blood Oxygenation and Sleep Patterns in Patients with Obstructive Sleep Apnea Diagnosed by Polysomnography |
title_full_unstemmed | A Retrospective Study to Compare the Use of the Mean Apnea-Hypopnea Duration and the Apnea-Hypopnea Index with Blood Oxygenation and Sleep Patterns in Patients with Obstructive Sleep Apnea Diagnosed by Polysomnography |
title_short | A Retrospective Study to Compare the Use of the Mean Apnea-Hypopnea Duration and the Apnea-Hypopnea Index with Blood Oxygenation and Sleep Patterns in Patients with Obstructive Sleep Apnea Diagnosed by Polysomnography |
title_sort | retrospective study to compare the use of the mean apnea-hypopnea duration and the apnea-hypopnea index with blood oxygenation and sleep patterns in patients with obstructive sleep apnea diagnosed by polysomnography |
topic | Clinical Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5892846/ https://www.ncbi.nlm.nih.gov/pubmed/29603712 http://dx.doi.org/10.12659/MSM.909219 |
work_keys_str_mv | AT zhanxiaojun aretrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography AT fangfang aretrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography AT wuchan aretrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography AT pintojayantm aretrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography AT weiyongxiang aretrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography AT zhanxiaojun retrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography AT fangfang retrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography AT wuchan retrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography AT pintojayantm retrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography AT weiyongxiang retrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography |