Cargando…

A Retrospective Study to Compare the Use of the Mean Apnea-Hypopnea Duration and the Apnea-Hypopnea Index with Blood Oxygenation and Sleep Patterns in Patients with Obstructive Sleep Apnea Diagnosed by Polysomnography

BACKGROUND: The apnea-hypopnea index (AHI) and the mean apnea-hypopnea duration (MAD) are used to measure the severity of the symptoms of obstructive sleep apnea (OSA). The aim of this study was to compare the use of the MAD with the AHI as indicators of clinical and demographic parameters, blood ox...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhan, Xiaojun, Fang, Fang, Wu, Chan, Pinto, Jayant M., Wei, Yongxiang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5892846/
https://www.ncbi.nlm.nih.gov/pubmed/29603712
http://dx.doi.org/10.12659/MSM.909219
_version_ 1783313217747943424
author Zhan, Xiaojun
Fang, Fang
Wu, Chan
Pinto, Jayant M.
Wei, Yongxiang
author_facet Zhan, Xiaojun
Fang, Fang
Wu, Chan
Pinto, Jayant M.
Wei, Yongxiang
author_sort Zhan, Xiaojun
collection PubMed
description BACKGROUND: The apnea-hypopnea index (AHI) and the mean apnea-hypopnea duration (MAD) are used to measure the severity of the symptoms of obstructive sleep apnea (OSA). The aim of this study was to compare the use of the MAD with the AHI as indicators of clinical and demographic parameters, blood oxygenation, and sleep parameters in patients diagnosed with OSA by polysomnography (PSG). MATERIAL/METHODS: A retrospective study included 511 patients with OSA diagnosed by PSG and who had the AHI and the MAD measured according to the guidelines from the American Academy of Sleep Medicine (AASM). The patients were divided into two groups: patients with a short MAD and with a long MAD, according to median duration, and using the inter-quartile range (IQR), as the data were not normally distributed. Clinical and demographic parameters were recorded. Pulse oximetry was used to measure blood oxygen saturation during sleep, sleep structure was recorded, and the Epworth Sleepiness Scale (ESS) questionnaire was used to measure daytime sleepiness. RESULTS: In all 511 patients with OSA, the MAD was significantly, but weakly, correlated with the AHI (r=0.17, P<0.01), but showed no significant associations with patient age (r=0.08, P=0.06), body weight (r=0.014, P=0.75), and height (r=0.06, P=0.16). Patients with a long MAD or severe OSA (n=260) had significantly worse blood oxygen levels and sleep parameters. CONCLUSIONS: For patients with severe OSA, this study showed that the MAD was a useful indicator of blood oxygenation and sleep parameters.
format Online
Article
Text
id pubmed-5892846
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-58928462018-04-18 A Retrospective Study to Compare the Use of the Mean Apnea-Hypopnea Duration and the Apnea-Hypopnea Index with Blood Oxygenation and Sleep Patterns in Patients with Obstructive Sleep Apnea Diagnosed by Polysomnography Zhan, Xiaojun Fang, Fang Wu, Chan Pinto, Jayant M. Wei, Yongxiang Med Sci Monit Clinical Research BACKGROUND: The apnea-hypopnea index (AHI) and the mean apnea-hypopnea duration (MAD) are used to measure the severity of the symptoms of obstructive sleep apnea (OSA). The aim of this study was to compare the use of the MAD with the AHI as indicators of clinical and demographic parameters, blood oxygenation, and sleep parameters in patients diagnosed with OSA by polysomnography (PSG). MATERIAL/METHODS: A retrospective study included 511 patients with OSA diagnosed by PSG and who had the AHI and the MAD measured according to the guidelines from the American Academy of Sleep Medicine (AASM). The patients were divided into two groups: patients with a short MAD and with a long MAD, according to median duration, and using the inter-quartile range (IQR), as the data were not normally distributed. Clinical and demographic parameters were recorded. Pulse oximetry was used to measure blood oxygen saturation during sleep, sleep structure was recorded, and the Epworth Sleepiness Scale (ESS) questionnaire was used to measure daytime sleepiness. RESULTS: In all 511 patients with OSA, the MAD was significantly, but weakly, correlated with the AHI (r=0.17, P<0.01), but showed no significant associations with patient age (r=0.08, P=0.06), body weight (r=0.014, P=0.75), and height (r=0.06, P=0.16). Patients with a long MAD or severe OSA (n=260) had significantly worse blood oxygen levels and sleep parameters. CONCLUSIONS: For patients with severe OSA, this study showed that the MAD was a useful indicator of blood oxygenation and sleep parameters. International Scientific Literature, Inc. 2018-03-31 /pmc/articles/PMC5892846/ /pubmed/29603712 http://dx.doi.org/10.12659/MSM.909219 Text en © Med Sci Monit, 2018 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
Zhan, Xiaojun
Fang, Fang
Wu, Chan
Pinto, Jayant M.
Wei, Yongxiang
A Retrospective Study to Compare the Use of the Mean Apnea-Hypopnea Duration and the Apnea-Hypopnea Index with Blood Oxygenation and Sleep Patterns in Patients with Obstructive Sleep Apnea Diagnosed by Polysomnography
title A Retrospective Study to Compare the Use of the Mean Apnea-Hypopnea Duration and the Apnea-Hypopnea Index with Blood Oxygenation and Sleep Patterns in Patients with Obstructive Sleep Apnea Diagnosed by Polysomnography
title_full A Retrospective Study to Compare the Use of the Mean Apnea-Hypopnea Duration and the Apnea-Hypopnea Index with Blood Oxygenation and Sleep Patterns in Patients with Obstructive Sleep Apnea Diagnosed by Polysomnography
title_fullStr A Retrospective Study to Compare the Use of the Mean Apnea-Hypopnea Duration and the Apnea-Hypopnea Index with Blood Oxygenation and Sleep Patterns in Patients with Obstructive Sleep Apnea Diagnosed by Polysomnography
title_full_unstemmed A Retrospective Study to Compare the Use of the Mean Apnea-Hypopnea Duration and the Apnea-Hypopnea Index with Blood Oxygenation and Sleep Patterns in Patients with Obstructive Sleep Apnea Diagnosed by Polysomnography
title_short A Retrospective Study to Compare the Use of the Mean Apnea-Hypopnea Duration and the Apnea-Hypopnea Index with Blood Oxygenation and Sleep Patterns in Patients with Obstructive Sleep Apnea Diagnosed by Polysomnography
title_sort retrospective study to compare the use of the mean apnea-hypopnea duration and the apnea-hypopnea index with blood oxygenation and sleep patterns in patients with obstructive sleep apnea diagnosed by polysomnography
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5892846/
https://www.ncbi.nlm.nih.gov/pubmed/29603712
http://dx.doi.org/10.12659/MSM.909219
work_keys_str_mv AT zhanxiaojun aretrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography
AT fangfang aretrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography
AT wuchan aretrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography
AT pintojayantm aretrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography
AT weiyongxiang aretrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography
AT zhanxiaojun retrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography
AT fangfang retrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography
AT wuchan retrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography
AT pintojayantm retrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography
AT weiyongxiang retrospectivestudytocomparetheuseofthemeanapneahypopneadurationandtheapneahypopneaindexwithbloodoxygenationandsleeppatternsinpatientswithobstructivesleepapneadiagnosedbypolysomnography