Comparison of the efficiency and complications of Lumenis and Wolf morcellators after holmium laser enucleation of the prostate
INTRODUCTION: Holmium laser enucleation of the prostate (HoLEP) is a recognized option for the surgical management of benign prostatic hyperplasia. While the laser parameters and enucleation techniques have been widely studied, the morcellation techniques still remain under-evaluated. The current st...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Medknow Publications & Media Pvt Ltd
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5894287/ https://www.ncbi.nlm.nih.gov/pubmed/29692508 http://dx.doi.org/10.4103/iju.IJU_133_17 |
_version_ | 1783313469841342464 |
---|---|
author | Maheshwari, Pankaj N. Wagaskar, Vinayak G. Maheshwari, Reeta P. |
author_facet | Maheshwari, Pankaj N. Wagaskar, Vinayak G. Maheshwari, Reeta P. |
author_sort | Maheshwari, Pankaj N. |
collection | PubMed |
description | INTRODUCTION: Holmium laser enucleation of the prostate (HoLEP) is a recognized option for the surgical management of benign prostatic hyperplasia. While the laser parameters and enucleation techniques have been widely studied, the morcellation techniques still remain under-evaluated. The current study evaluates the two commonly used morcellation devices for their in vivo efficiency and patient safety. MATERIALS AND METHODS: A total of 222 patients who underwent HoLEP at two medical centres between January 2011 to December 2013 by a single surgeon were included. Of these 222 patients, the Richard Wolf Piranha Morcellation System, Germany (WM), was used on 140 patients, while on the remaining 82, the Lumenis(®) VersaCut™ Morcellator, Yokneam, Israel (LM), was used. These devices were compared for safety parameters such as the incidence of bladder mucosal injury, deep muscle injury, bladder perforation, and bleeding requiring electrocoagulation. The morcellation efficiency (ME) defined as the ratio of the weight of morcellated tissue in grams to the time required for morcellation in minutes was also compared. RESULTS: The incidence of bladder mucosal injury, deep muscle injury, and bleeding requiring electrocoagulation was statistically significantly lower for the WM than the LM. None of the patients had a full-thickness bladder perforation with either of the morcellators. The ME was higher for the LM. In eight patients, hard, smooth rounded adenomatous nodules could not be morcellated by the WM and had to be crushed by a stone grasping forceps before morcellation. CONCLUSIONS: While the LM is a faster morcellator, WM has a better safety profile. |
format | Online Article Text |
id | pubmed-5894287 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Medknow Publications & Media Pvt Ltd |
record_format | MEDLINE/PubMed |
spelling | pubmed-58942872018-04-24 Comparison of the efficiency and complications of Lumenis and Wolf morcellators after holmium laser enucleation of the prostate Maheshwari, Pankaj N. Wagaskar, Vinayak G. Maheshwari, Reeta P. Indian J Urol Original Article INTRODUCTION: Holmium laser enucleation of the prostate (HoLEP) is a recognized option for the surgical management of benign prostatic hyperplasia. While the laser parameters and enucleation techniques have been widely studied, the morcellation techniques still remain under-evaluated. The current study evaluates the two commonly used morcellation devices for their in vivo efficiency and patient safety. MATERIALS AND METHODS: A total of 222 patients who underwent HoLEP at two medical centres between January 2011 to December 2013 by a single surgeon were included. Of these 222 patients, the Richard Wolf Piranha Morcellation System, Germany (WM), was used on 140 patients, while on the remaining 82, the Lumenis(®) VersaCut™ Morcellator, Yokneam, Israel (LM), was used. These devices were compared for safety parameters such as the incidence of bladder mucosal injury, deep muscle injury, bladder perforation, and bleeding requiring electrocoagulation. The morcellation efficiency (ME) defined as the ratio of the weight of morcellated tissue in grams to the time required for morcellation in minutes was also compared. RESULTS: The incidence of bladder mucosal injury, deep muscle injury, and bleeding requiring electrocoagulation was statistically significantly lower for the WM than the LM. None of the patients had a full-thickness bladder perforation with either of the morcellators. The ME was higher for the LM. In eight patients, hard, smooth rounded adenomatous nodules could not be morcellated by the WM and had to be crushed by a stone grasping forceps before morcellation. CONCLUSIONS: While the LM is a faster morcellator, WM has a better safety profile. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC5894287/ /pubmed/29692508 http://dx.doi.org/10.4103/iju.IJU_133_17 Text en Copyright: © 2018 Indian Journal of Urology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Maheshwari, Pankaj N. Wagaskar, Vinayak G. Maheshwari, Reeta P. Comparison of the efficiency and complications of Lumenis and Wolf morcellators after holmium laser enucleation of the prostate |
title | Comparison of the efficiency and complications of Lumenis and Wolf morcellators after holmium laser enucleation of the prostate |
title_full | Comparison of the efficiency and complications of Lumenis and Wolf morcellators after holmium laser enucleation of the prostate |
title_fullStr | Comparison of the efficiency and complications of Lumenis and Wolf morcellators after holmium laser enucleation of the prostate |
title_full_unstemmed | Comparison of the efficiency and complications of Lumenis and Wolf morcellators after holmium laser enucleation of the prostate |
title_short | Comparison of the efficiency and complications of Lumenis and Wolf morcellators after holmium laser enucleation of the prostate |
title_sort | comparison of the efficiency and complications of lumenis and wolf morcellators after holmium laser enucleation of the prostate |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5894287/ https://www.ncbi.nlm.nih.gov/pubmed/29692508 http://dx.doi.org/10.4103/iju.IJU_133_17 |
work_keys_str_mv | AT maheshwaripankajn comparisonoftheefficiencyandcomplicationsoflumenisandwolfmorcellatorsafterholmiumlaserenucleationoftheprostate AT wagaskarvinayakg comparisonoftheefficiencyandcomplicationsoflumenisandwolfmorcellatorsafterholmiumlaserenucleationoftheprostate AT maheshwarireetap comparisonoftheefficiencyandcomplicationsoflumenisandwolfmorcellatorsafterholmiumlaserenucleationoftheprostate |