Cargando…

Comparison of the efficiency and complications of Lumenis and Wolf morcellators after holmium laser enucleation of the prostate

INTRODUCTION: Holmium laser enucleation of the prostate (HoLEP) is a recognized option for the surgical management of benign prostatic hyperplasia. While the laser parameters and enucleation techniques have been widely studied, the morcellation techniques still remain under-evaluated. The current st...

Descripción completa

Detalles Bibliográficos
Autores principales: Maheshwari, Pankaj N., Wagaskar, Vinayak G., Maheshwari, Reeta P.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5894287/
https://www.ncbi.nlm.nih.gov/pubmed/29692508
http://dx.doi.org/10.4103/iju.IJU_133_17
_version_ 1783313469841342464
author Maheshwari, Pankaj N.
Wagaskar, Vinayak G.
Maheshwari, Reeta P.
author_facet Maheshwari, Pankaj N.
Wagaskar, Vinayak G.
Maheshwari, Reeta P.
author_sort Maheshwari, Pankaj N.
collection PubMed
description INTRODUCTION: Holmium laser enucleation of the prostate (HoLEP) is a recognized option for the surgical management of benign prostatic hyperplasia. While the laser parameters and enucleation techniques have been widely studied, the morcellation techniques still remain under-evaluated. The current study evaluates the two commonly used morcellation devices for their in vivo efficiency and patient safety. MATERIALS AND METHODS: A total of 222 patients who underwent HoLEP at two medical centres between January 2011 to December 2013 by a single surgeon were included. Of these 222 patients, the Richard Wolf Piranha Morcellation System, Germany (WM), was used on 140 patients, while on the remaining 82, the Lumenis(®) VersaCut™ Morcellator, Yokneam, Israel (LM), was used. These devices were compared for safety parameters such as the incidence of bladder mucosal injury, deep muscle injury, bladder perforation, and bleeding requiring electrocoagulation. The morcellation efficiency (ME) defined as the ratio of the weight of morcellated tissue in grams to the time required for morcellation in minutes was also compared. RESULTS: The incidence of bladder mucosal injury, deep muscle injury, and bleeding requiring electrocoagulation was statistically significantly lower for the WM than the LM. None of the patients had a full-thickness bladder perforation with either of the morcellators. The ME was higher for the LM. In eight patients, hard, smooth rounded adenomatous nodules could not be morcellated by the WM and had to be crushed by a stone grasping forceps before morcellation. CONCLUSIONS: While the LM is a faster morcellator, WM has a better safety profile.
format Online
Article
Text
id pubmed-5894287
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-58942872018-04-24 Comparison of the efficiency and complications of Lumenis and Wolf morcellators after holmium laser enucleation of the prostate Maheshwari, Pankaj N. Wagaskar, Vinayak G. Maheshwari, Reeta P. Indian J Urol Original Article INTRODUCTION: Holmium laser enucleation of the prostate (HoLEP) is a recognized option for the surgical management of benign prostatic hyperplasia. While the laser parameters and enucleation techniques have been widely studied, the morcellation techniques still remain under-evaluated. The current study evaluates the two commonly used morcellation devices for their in vivo efficiency and patient safety. MATERIALS AND METHODS: A total of 222 patients who underwent HoLEP at two medical centres between January 2011 to December 2013 by a single surgeon were included. Of these 222 patients, the Richard Wolf Piranha Morcellation System, Germany (WM), was used on 140 patients, while on the remaining 82, the Lumenis(®) VersaCut™ Morcellator, Yokneam, Israel (LM), was used. These devices were compared for safety parameters such as the incidence of bladder mucosal injury, deep muscle injury, bladder perforation, and bleeding requiring electrocoagulation. The morcellation efficiency (ME) defined as the ratio of the weight of morcellated tissue in grams to the time required for morcellation in minutes was also compared. RESULTS: The incidence of bladder mucosal injury, deep muscle injury, and bleeding requiring electrocoagulation was statistically significantly lower for the WM than the LM. None of the patients had a full-thickness bladder perforation with either of the morcellators. The ME was higher for the LM. In eight patients, hard, smooth rounded adenomatous nodules could not be morcellated by the WM and had to be crushed by a stone grasping forceps before morcellation. CONCLUSIONS: While the LM is a faster morcellator, WM has a better safety profile. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC5894287/ /pubmed/29692508 http://dx.doi.org/10.4103/iju.IJU_133_17 Text en Copyright: © 2018 Indian Journal of Urology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Maheshwari, Pankaj N.
Wagaskar, Vinayak G.
Maheshwari, Reeta P.
Comparison of the efficiency and complications of Lumenis and Wolf morcellators after holmium laser enucleation of the prostate
title Comparison of the efficiency and complications of Lumenis and Wolf morcellators after holmium laser enucleation of the prostate
title_full Comparison of the efficiency and complications of Lumenis and Wolf morcellators after holmium laser enucleation of the prostate
title_fullStr Comparison of the efficiency and complications of Lumenis and Wolf morcellators after holmium laser enucleation of the prostate
title_full_unstemmed Comparison of the efficiency and complications of Lumenis and Wolf morcellators after holmium laser enucleation of the prostate
title_short Comparison of the efficiency and complications of Lumenis and Wolf morcellators after holmium laser enucleation of the prostate
title_sort comparison of the efficiency and complications of lumenis and wolf morcellators after holmium laser enucleation of the prostate
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5894287/
https://www.ncbi.nlm.nih.gov/pubmed/29692508
http://dx.doi.org/10.4103/iju.IJU_133_17
work_keys_str_mv AT maheshwaripankajn comparisonoftheefficiencyandcomplicationsoflumenisandwolfmorcellatorsafterholmiumlaserenucleationoftheprostate
AT wagaskarvinayakg comparisonoftheefficiencyandcomplicationsoflumenisandwolfmorcellatorsafterholmiumlaserenucleationoftheprostate
AT maheshwarireetap comparisonoftheefficiencyandcomplicationsoflumenisandwolfmorcellatorsafterholmiumlaserenucleationoftheprostate