Cargando…

The combination of a reduction in contrast agent dose with low tube voltage and an adaptive statistical iterative reconstruction algorithm in CT enterography: Effects on image quality and radiation dose

To investigate the subjective and quantitative image quality and radiation exposure of CT enterography (CTE) examination performed at low tube voltage and low concentration of contrast agent with adaptive statistical iterative reconstruction (ASIR) algorithm, compared with conventional CTE. One hund...

Descripción completa

Detalles Bibliográficos
Autores principales: Feng, Cui, Zhu, Di, Zou, Xianlun, Li, Anqin, Hu, Xuemei, Li, Zhen, Hu, Daoyu
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer Health 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5895339/
https://www.ncbi.nlm.nih.gov/pubmed/29561422
http://dx.doi.org/10.1097/MD.0000000000010151
_version_ 1783313639321632768
author Feng, Cui
Zhu, Di
Zou, Xianlun
Li, Anqin
Hu, Xuemei
Li, Zhen
Hu, Daoyu
author_facet Feng, Cui
Zhu, Di
Zou, Xianlun
Li, Anqin
Hu, Xuemei
Li, Zhen
Hu, Daoyu
author_sort Feng, Cui
collection PubMed
description To investigate the subjective and quantitative image quality and radiation exposure of CT enterography (CTE) examination performed at low tube voltage and low concentration of contrast agent with adaptive statistical iterative reconstruction (ASIR) algorithm, compared with conventional CTE. One hundred thirty-seven patients with suspected or proved gastrointestinal diseases underwent contrast enhanced CTE in a multidetector computed tomography (MDCT) scanner. All cases were assigned to 2 groups. Group A (n = 79) underwent CT with low tube voltage based on patient body mass index (BMI) (BMI < 23 kg/m(2), 80 kVp; BMI ≥ 23 kg/m(2), 100 kVp) and low concentration of contrast agent (270 mg I/mL), the images were reconstructed with standard filtered back projection (FBP) algorithm and 50% ASIR algorithm. Group B (n = 58) underwent conventional CTE with 120 kVp and 350 mg I/mL contrast agent, the images were reconstructed with FBP algorithm. The computed tomography dose index volume (CTDI(vol)), dose length product (DLP), effective dose (ED), and total iodine dosage were calculated and compared. The CT values, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) of the normal bowel wall, gastrointestinal lesions, and mesenteric vessels were assessed and compared. The subjective image quality was assessed independently and blindly by 2 radiologists using a 5-point Likert scale. The differences of values for CTDI(vol) (8.64 ± 2.72 vs 11.55 ± 3.95, P < .001), ED (6.34 ± 2.24 vs 8.52 ± 3.02, P < .001), and DLP (422.6 ± 149.40 vs 568.30 ± 213.90, P < .001) were significant between group A and group B, with a reduction of 25.2%, 25.7%, and 25.7% in group A, respectively. The total iodine dosage in group A was reduced by 26.1%. The subjective image quality did not differ between the 2 groups (P > .05) and all image quality scores were greater than or equal to 3 (moderate). Fifty percent ASIR-A group images provided lower image noise, but similar or higher quantitative image quality in comparison with FBP-B group images. Compared with the conventional protocol, CTE performed at low tube voltage, low concentration of contrast agent with 50% ASIR algorithm produce a diagnostically acceptable image quality with a mean ED of 6.34 mSv and a total iodine dose reduction of 26.1%.
format Online
Article
Text
id pubmed-5895339
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Wolters Kluwer Health
record_format MEDLINE/PubMed
spelling pubmed-58953392018-04-18 The combination of a reduction in contrast agent dose with low tube voltage and an adaptive statistical iterative reconstruction algorithm in CT enterography: Effects on image quality and radiation dose Feng, Cui Zhu, Di Zou, Xianlun Li, Anqin Hu, Xuemei Li, Zhen Hu, Daoyu Medicine (Baltimore) 6800 To investigate the subjective and quantitative image quality and radiation exposure of CT enterography (CTE) examination performed at low tube voltage and low concentration of contrast agent with adaptive statistical iterative reconstruction (ASIR) algorithm, compared with conventional CTE. One hundred thirty-seven patients with suspected or proved gastrointestinal diseases underwent contrast enhanced CTE in a multidetector computed tomography (MDCT) scanner. All cases were assigned to 2 groups. Group A (n = 79) underwent CT with low tube voltage based on patient body mass index (BMI) (BMI < 23 kg/m(2), 80 kVp; BMI ≥ 23 kg/m(2), 100 kVp) and low concentration of contrast agent (270 mg I/mL), the images were reconstructed with standard filtered back projection (FBP) algorithm and 50% ASIR algorithm. Group B (n = 58) underwent conventional CTE with 120 kVp and 350 mg I/mL contrast agent, the images were reconstructed with FBP algorithm. The computed tomography dose index volume (CTDI(vol)), dose length product (DLP), effective dose (ED), and total iodine dosage were calculated and compared. The CT values, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) of the normal bowel wall, gastrointestinal lesions, and mesenteric vessels were assessed and compared. The subjective image quality was assessed independently and blindly by 2 radiologists using a 5-point Likert scale. The differences of values for CTDI(vol) (8.64 ± 2.72 vs 11.55 ± 3.95, P < .001), ED (6.34 ± 2.24 vs 8.52 ± 3.02, P < .001), and DLP (422.6 ± 149.40 vs 568.30 ± 213.90, P < .001) were significant between group A and group B, with a reduction of 25.2%, 25.7%, and 25.7% in group A, respectively. The total iodine dosage in group A was reduced by 26.1%. The subjective image quality did not differ between the 2 groups (P > .05) and all image quality scores were greater than or equal to 3 (moderate). Fifty percent ASIR-A group images provided lower image noise, but similar or higher quantitative image quality in comparison with FBP-B group images. Compared with the conventional protocol, CTE performed at low tube voltage, low concentration of contrast agent with 50% ASIR algorithm produce a diagnostically acceptable image quality with a mean ED of 6.34 mSv and a total iodine dose reduction of 26.1%. Wolters Kluwer Health 2018-03-23 /pmc/articles/PMC5895339/ /pubmed/29561422 http://dx.doi.org/10.1097/MD.0000000000010151 Text en Copyright © 2018 the Author(s). Published by Wolters Kluwer Health, Inc. http://creativecommons.org/licenses/by-nd/4.0 This is an open access article distributed under the Creative Commons Attribution-NoDerivatives License 4.0, which allows for redistribution, commercial and non-commercial, as long as it is passed along unchanged and in whole, with credit to the author. http://creativecommons.org/licenses/by-nd/4.0
spellingShingle 6800
Feng, Cui
Zhu, Di
Zou, Xianlun
Li, Anqin
Hu, Xuemei
Li, Zhen
Hu, Daoyu
The combination of a reduction in contrast agent dose with low tube voltage and an adaptive statistical iterative reconstruction algorithm in CT enterography: Effects on image quality and radiation dose
title The combination of a reduction in contrast agent dose with low tube voltage and an adaptive statistical iterative reconstruction algorithm in CT enterography: Effects on image quality and radiation dose
title_full The combination of a reduction in contrast agent dose with low tube voltage and an adaptive statistical iterative reconstruction algorithm in CT enterography: Effects on image quality and radiation dose
title_fullStr The combination of a reduction in contrast agent dose with low tube voltage and an adaptive statistical iterative reconstruction algorithm in CT enterography: Effects on image quality and radiation dose
title_full_unstemmed The combination of a reduction in contrast agent dose with low tube voltage and an adaptive statistical iterative reconstruction algorithm in CT enterography: Effects on image quality and radiation dose
title_short The combination of a reduction in contrast agent dose with low tube voltage and an adaptive statistical iterative reconstruction algorithm in CT enterography: Effects on image quality and radiation dose
title_sort combination of a reduction in contrast agent dose with low tube voltage and an adaptive statistical iterative reconstruction algorithm in ct enterography: effects on image quality and radiation dose
topic 6800
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5895339/
https://www.ncbi.nlm.nih.gov/pubmed/29561422
http://dx.doi.org/10.1097/MD.0000000000010151
work_keys_str_mv AT fengcui thecombinationofareductionincontrastagentdosewithlowtubevoltageandanadaptivestatisticaliterativereconstructionalgorithminctenterographyeffectsonimagequalityandradiationdose
AT zhudi thecombinationofareductionincontrastagentdosewithlowtubevoltageandanadaptivestatisticaliterativereconstructionalgorithminctenterographyeffectsonimagequalityandradiationdose
AT zouxianlun thecombinationofareductionincontrastagentdosewithlowtubevoltageandanadaptivestatisticaliterativereconstructionalgorithminctenterographyeffectsonimagequalityandradiationdose
AT lianqin thecombinationofareductionincontrastagentdosewithlowtubevoltageandanadaptivestatisticaliterativereconstructionalgorithminctenterographyeffectsonimagequalityandradiationdose
AT huxuemei thecombinationofareductionincontrastagentdosewithlowtubevoltageandanadaptivestatisticaliterativereconstructionalgorithminctenterographyeffectsonimagequalityandradiationdose
AT lizhen thecombinationofareductionincontrastagentdosewithlowtubevoltageandanadaptivestatisticaliterativereconstructionalgorithminctenterographyeffectsonimagequalityandradiationdose
AT hudaoyu thecombinationofareductionincontrastagentdosewithlowtubevoltageandanadaptivestatisticaliterativereconstructionalgorithminctenterographyeffectsonimagequalityandradiationdose
AT fengcui combinationofareductionincontrastagentdosewithlowtubevoltageandanadaptivestatisticaliterativereconstructionalgorithminctenterographyeffectsonimagequalityandradiationdose
AT zhudi combinationofareductionincontrastagentdosewithlowtubevoltageandanadaptivestatisticaliterativereconstructionalgorithminctenterographyeffectsonimagequalityandradiationdose
AT zouxianlun combinationofareductionincontrastagentdosewithlowtubevoltageandanadaptivestatisticaliterativereconstructionalgorithminctenterographyeffectsonimagequalityandradiationdose
AT lianqin combinationofareductionincontrastagentdosewithlowtubevoltageandanadaptivestatisticaliterativereconstructionalgorithminctenterographyeffectsonimagequalityandradiationdose
AT huxuemei combinationofareductionincontrastagentdosewithlowtubevoltageandanadaptivestatisticaliterativereconstructionalgorithminctenterographyeffectsonimagequalityandradiationdose
AT lizhen combinationofareductionincontrastagentdosewithlowtubevoltageandanadaptivestatisticaliterativereconstructionalgorithminctenterographyeffectsonimagequalityandradiationdose
AT hudaoyu combinationofareductionincontrastagentdosewithlowtubevoltageandanadaptivestatisticaliterativereconstructionalgorithminctenterographyeffectsonimagequalityandradiationdose