Cargando…
Sorbent Film-Coated Passive Samplers for Explosives Vapour Detection Part A: Materials Optimisation and Integration with Analytical Technologies
A new thin-film passive sampler is presented as a low resource dependent and discrete continuous monitoring solution for explosives-related vapours. Using 15 mid-high vapour pressure explosives-related compounds as probes, combinations of four thermally stable substrates and six film-based sorbents...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5895691/ https://www.ncbi.nlm.nih.gov/pubmed/29643465 http://dx.doi.org/10.1038/s41598-018-24244-y |
_version_ | 1783313699133456384 |
---|---|
author | McEneff, Gillian L. Murphy, Bronagh Webb, Tony Wood, Dan Irlam, Rachel Mills, Jim Green, David Barron, Leon P. |
author_facet | McEneff, Gillian L. Murphy, Bronagh Webb, Tony Wood, Dan Irlam, Rachel Mills, Jim Green, David Barron, Leon P. |
author_sort | McEneff, Gillian L. |
collection | PubMed |
description | A new thin-film passive sampler is presented as a low resource dependent and discrete continuous monitoring solution for explosives-related vapours. Using 15 mid-high vapour pressure explosives-related compounds as probes, combinations of four thermally stable substrates and six film-based sorbents were evaluated. Meta-aramid and phenylene oxide-based materials showed the best recoveries from small voids (~70%). Analysis was performed using liquid chromatography-high resolution accurate mass spectrometry which also enabled tentative identification of new targets from the acquired data. Preliminary uptake kinetics experiments revealed plateau concentrations on the device were reached between 3–5 days. Compounds used in improvised explosive devices, such as triacetone triperoxide, were detected within 1 hour and were stably retained by the sampler for up to 7 days. Sampler performance was consistent for 22 months after manufacture. Lastly, its direct integration with currently in-service explosives screening equipment including ion mobility spectrometry and thermal desorption mass spectrometry is presented. Following exposure to several open environments and targeted interferences, sampler performance was subsequently assessed and potential interferences identified. High-security building and area monitoring for concealed explosives using such cost-effective and discrete passive samplers can add extra assurance to search routines while minimising any additional burden on personnel or everyday site operation. |
format | Online Article Text |
id | pubmed-5895691 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-58956912018-04-20 Sorbent Film-Coated Passive Samplers for Explosives Vapour Detection Part A: Materials Optimisation and Integration with Analytical Technologies McEneff, Gillian L. Murphy, Bronagh Webb, Tony Wood, Dan Irlam, Rachel Mills, Jim Green, David Barron, Leon P. Sci Rep Article A new thin-film passive sampler is presented as a low resource dependent and discrete continuous monitoring solution for explosives-related vapours. Using 15 mid-high vapour pressure explosives-related compounds as probes, combinations of four thermally stable substrates and six film-based sorbents were evaluated. Meta-aramid and phenylene oxide-based materials showed the best recoveries from small voids (~70%). Analysis was performed using liquid chromatography-high resolution accurate mass spectrometry which also enabled tentative identification of new targets from the acquired data. Preliminary uptake kinetics experiments revealed plateau concentrations on the device were reached between 3–5 days. Compounds used in improvised explosive devices, such as triacetone triperoxide, were detected within 1 hour and were stably retained by the sampler for up to 7 days. Sampler performance was consistent for 22 months after manufacture. Lastly, its direct integration with currently in-service explosives screening equipment including ion mobility spectrometry and thermal desorption mass spectrometry is presented. Following exposure to several open environments and targeted interferences, sampler performance was subsequently assessed and potential interferences identified. High-security building and area monitoring for concealed explosives using such cost-effective and discrete passive samplers can add extra assurance to search routines while minimising any additional burden on personnel or everyday site operation. Nature Publishing Group UK 2018-04-11 /pmc/articles/PMC5895691/ /pubmed/29643465 http://dx.doi.org/10.1038/s41598-018-24244-y Text en © The Author(s) 2018 Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/. |
spellingShingle | Article McEneff, Gillian L. Murphy, Bronagh Webb, Tony Wood, Dan Irlam, Rachel Mills, Jim Green, David Barron, Leon P. Sorbent Film-Coated Passive Samplers for Explosives Vapour Detection Part A: Materials Optimisation and Integration with Analytical Technologies |
title | Sorbent Film-Coated Passive Samplers for Explosives Vapour Detection Part A: Materials Optimisation and Integration with Analytical Technologies |
title_full | Sorbent Film-Coated Passive Samplers for Explosives Vapour Detection Part A: Materials Optimisation and Integration with Analytical Technologies |
title_fullStr | Sorbent Film-Coated Passive Samplers for Explosives Vapour Detection Part A: Materials Optimisation and Integration with Analytical Technologies |
title_full_unstemmed | Sorbent Film-Coated Passive Samplers for Explosives Vapour Detection Part A: Materials Optimisation and Integration with Analytical Technologies |
title_short | Sorbent Film-Coated Passive Samplers for Explosives Vapour Detection Part A: Materials Optimisation and Integration with Analytical Technologies |
title_sort | sorbent film-coated passive samplers for explosives vapour detection part a: materials optimisation and integration with analytical technologies |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5895691/ https://www.ncbi.nlm.nih.gov/pubmed/29643465 http://dx.doi.org/10.1038/s41598-018-24244-y |
work_keys_str_mv | AT mceneffgillianl sorbentfilmcoatedpassivesamplersforexplosivesvapourdetectionpartamaterialsoptimisationandintegrationwithanalyticaltechnologies AT murphybronagh sorbentfilmcoatedpassivesamplersforexplosivesvapourdetectionpartamaterialsoptimisationandintegrationwithanalyticaltechnologies AT webbtony sorbentfilmcoatedpassivesamplersforexplosivesvapourdetectionpartamaterialsoptimisationandintegrationwithanalyticaltechnologies AT wooddan sorbentfilmcoatedpassivesamplersforexplosivesvapourdetectionpartamaterialsoptimisationandintegrationwithanalyticaltechnologies AT irlamrachel sorbentfilmcoatedpassivesamplersforexplosivesvapourdetectionpartamaterialsoptimisationandintegrationwithanalyticaltechnologies AT millsjim sorbentfilmcoatedpassivesamplersforexplosivesvapourdetectionpartamaterialsoptimisationandintegrationwithanalyticaltechnologies AT greendavid sorbentfilmcoatedpassivesamplersforexplosivesvapourdetectionpartamaterialsoptimisationandintegrationwithanalyticaltechnologies AT barronleonp sorbentfilmcoatedpassivesamplersforexplosivesvapourdetectionpartamaterialsoptimisationandintegrationwithanalyticaltechnologies |