Cargando…

Maximizing the fixation strength of modular components by impaction without tissue damage

OBJECTIVES: Taper junctions between modular hip arthroplasty femoral heads and stems fail by wear or corrosion which can be caused by relative motion at their interface. Increasing the assembly force can reduce relative motion and corrosion but may also damage surrounding tissues. The purpose of thi...

Descripción completa

Detalles Bibliográficos
Autores principales: Krull, A., Morlock, M. M., Bishop, N. E.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5895944/
https://www.ncbi.nlm.nih.gov/pubmed/29682286
http://dx.doi.org/10.1302/2046-3758.72.BJR-2017-0078.R2
_version_ 1783313746329862144
author Krull, A.
Morlock, M. M.
Bishop, N. E.
author_facet Krull, A.
Morlock, M. M.
Bishop, N. E.
author_sort Krull, A.
collection PubMed
description OBJECTIVES: Taper junctions between modular hip arthroplasty femoral heads and stems fail by wear or corrosion which can be caused by relative motion at their interface. Increasing the assembly force can reduce relative motion and corrosion but may also damage surrounding tissues. The purpose of this study was to determine the effects of increasing the impaction energy and the stiffness of the impactor tool on the stability of the taper junction and on the forces transmitted through the patient’s surrounding tissues. METHODS: A commercially available impaction tool was modified to assemble components in the laboratory using impactor tips with varying stiffness at different applied energy levels. Springs were mounted below the modular components to represent the patient. The pull-off force of the head from the stem was measured to assess stability, and the displacement of the springs was measured to assess the force transmitted to the patient’s tissues. RESULTS: The pull-off force of the head increased as the stiffness of the impactor tip increased but without increasing the force transmitted through the springs (patient). Increasing the impaction energy increased the pull-off force but also increased the force transmitted through the springs. CONCLUSIONS: To limit wear and corrosion, manufacturers should maximize the stiffness of the impactor tool but without damaging the surface of the head. This strategy will maximize the stability of the head on the stem for a given applied energy, without influencing the force transmitted through the patient’s tissues. Current impactor designs already appear to approach this limit. Increasing the applied energy (which is dependent on the mass of the hammer and square of the contact speed) increases the stability of the modular connection but proportionally increases the force transmitted through the patient’s tissues, as well as to the surface of the head, and should be restricted to safe levels. Cite this article: A. Krull, M. M. Morlock, N. E. Bishop. Maximizing the fixation strength of modular components by impaction without tissue damage. Bone Joint Res 2018;7:196–204. DOI: 10.1302/2046-3758.72.BJR-2017-0078.R2.
format Online
Article
Text
id pubmed-5895944
institution National Center for Biotechnology Information
language English
publishDate 2018
record_format MEDLINE/PubMed
spelling pubmed-58959442018-04-20 Maximizing the fixation strength of modular components by impaction without tissue damage Krull, A. Morlock, M. M. Bishop, N. E. Bone Joint Res Research OBJECTIVES: Taper junctions between modular hip arthroplasty femoral heads and stems fail by wear or corrosion which can be caused by relative motion at their interface. Increasing the assembly force can reduce relative motion and corrosion but may also damage surrounding tissues. The purpose of this study was to determine the effects of increasing the impaction energy and the stiffness of the impactor tool on the stability of the taper junction and on the forces transmitted through the patient’s surrounding tissues. METHODS: A commercially available impaction tool was modified to assemble components in the laboratory using impactor tips with varying stiffness at different applied energy levels. Springs were mounted below the modular components to represent the patient. The pull-off force of the head from the stem was measured to assess stability, and the displacement of the springs was measured to assess the force transmitted to the patient’s tissues. RESULTS: The pull-off force of the head increased as the stiffness of the impactor tip increased but without increasing the force transmitted through the springs (patient). Increasing the impaction energy increased the pull-off force but also increased the force transmitted through the springs. CONCLUSIONS: To limit wear and corrosion, manufacturers should maximize the stiffness of the impactor tool but without damaging the surface of the head. This strategy will maximize the stability of the head on the stem for a given applied energy, without influencing the force transmitted through the patient’s tissues. Current impactor designs already appear to approach this limit. Increasing the applied energy (which is dependent on the mass of the hammer and square of the contact speed) increases the stability of the modular connection but proportionally increases the force transmitted through the patient’s tissues, as well as to the surface of the head, and should be restricted to safe levels. Cite this article: A. Krull, M. M. Morlock, N. E. Bishop. Maximizing the fixation strength of modular components by impaction without tissue damage. Bone Joint Res 2018;7:196–204. DOI: 10.1302/2046-3758.72.BJR-2017-0078.R2. 2018-04-12 /pmc/articles/PMC5895944/ /pubmed/29682286 http://dx.doi.org/10.1302/2046-3758.72.BJR-2017-0078.R2 Text en © 2018 Krull et al. This is an open-access article distributed under the terms of the Creative Commons Attributions licence (CC-BY-NC), which permits unrestricted use, distribution, and reproduction in any medium, but not for commercial gain, provided the original author and source are credited.
spellingShingle Research
Krull, A.
Morlock, M. M.
Bishop, N. E.
Maximizing the fixation strength of modular components by impaction without tissue damage
title Maximizing the fixation strength of modular components by impaction without tissue damage
title_full Maximizing the fixation strength of modular components by impaction without tissue damage
title_fullStr Maximizing the fixation strength of modular components by impaction without tissue damage
title_full_unstemmed Maximizing the fixation strength of modular components by impaction without tissue damage
title_short Maximizing the fixation strength of modular components by impaction without tissue damage
title_sort maximizing the fixation strength of modular components by impaction without tissue damage
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5895944/
https://www.ncbi.nlm.nih.gov/pubmed/29682286
http://dx.doi.org/10.1302/2046-3758.72.BJR-2017-0078.R2
work_keys_str_mv AT krulla maximizingthefixationstrengthofmodularcomponentsbyimpactionwithouttissuedamage
AT morlockmm maximizingthefixationstrengthofmodularcomponentsbyimpactionwithouttissuedamage
AT bishopne maximizingthefixationstrengthofmodularcomponentsbyimpactionwithouttissuedamage