Cargando…

Torque Control During Intrusion on Upper Central Incisor in Labial and Lingual bracket System - A 3D Finite Element Study

BACKGROUND: The aim of present study was to investigate the difference of torque control during intrusive force on upper central incisors with normal, under and high torque in lingual and labial orthodontic systems through 3D finite element analysis. MATERIAL AND METHODS: Six 3D models of an upper r...

Descripción completa

Detalles Bibliográficos
Autores principales: Pol, Tejas R., Vandekar, Meghna, Patil, Anuradha, Desai, Sanjana, Shetty, Vikram, Hazarika, Saptarshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medicina Oral S.L. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5899806/
https://www.ncbi.nlm.nih.gov/pubmed/29670711
http://dx.doi.org/10.4317/jced.54461
_version_ 1783314312846114816
author Pol, Tejas R.
Vandekar, Meghna
Patil, Anuradha
Desai, Sanjana
Shetty, Vikram
Hazarika, Saptarshi
author_facet Pol, Tejas R.
Vandekar, Meghna
Patil, Anuradha
Desai, Sanjana
Shetty, Vikram
Hazarika, Saptarshi
author_sort Pol, Tejas R.
collection PubMed
description BACKGROUND: The aim of present study was to investigate the difference of torque control during intrusive force on upper central incisors with normal, under and high torque in lingual and labial orthodontic systems through 3D finite element analysis. MATERIAL AND METHODS: Six 3D models of an upper right central incisor with different torque were designed in Solid Works 2006. Software ANSYS Version 16.0 was used to evaluate intrusive force on upper central incisor model . An intrusive force of 0.15 N was applied to the bracket slot in different torque models and the displacements along a path of nodes in the upper central incisor was assessed. RESULTS: On application of Intrusive force on under torqued upper central incisor in Labial system produce labial crown movement but in Lingual system caused lingual movement in the apical and incisal parts. The same intrusive force in normal-torqued central incisor led to a palatal movement in apical and labial displacement of incisal edge in Lingual system and a palatal displacement in apical area and a labial movement in the incisal edge in Labial systemin. In overtorqued upper central incisor, the labial crown displacement in Labial system is more than Lingual system. CONCLUSIONS: In labial and lingual system on application of the same forces in upper central incisor with different inclinations showed different responses. The magnitudes of torque Loss during intrusive loads in incisors with normal, under and over-torque were higher in Labial system than Lingual orthodontic appliances. Key words:FEM, lingual orthodontics, intrusion, torque control, labial bracket systems
format Online
Article
Text
id pubmed-5899806
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medicina Oral S.L.
record_format MEDLINE/PubMed
spelling pubmed-58998062018-04-18 Torque Control During Intrusion on Upper Central Incisor in Labial and Lingual bracket System - A 3D Finite Element Study Pol, Tejas R. Vandekar, Meghna Patil, Anuradha Desai, Sanjana Shetty, Vikram Hazarika, Saptarshi J Clin Exp Dent Research BACKGROUND: The aim of present study was to investigate the difference of torque control during intrusive force on upper central incisors with normal, under and high torque in lingual and labial orthodontic systems through 3D finite element analysis. MATERIAL AND METHODS: Six 3D models of an upper right central incisor with different torque were designed in Solid Works 2006. Software ANSYS Version 16.0 was used to evaluate intrusive force on upper central incisor model . An intrusive force of 0.15 N was applied to the bracket slot in different torque models and the displacements along a path of nodes in the upper central incisor was assessed. RESULTS: On application of Intrusive force on under torqued upper central incisor in Labial system produce labial crown movement but in Lingual system caused lingual movement in the apical and incisal parts. The same intrusive force in normal-torqued central incisor led to a palatal movement in apical and labial displacement of incisal edge in Lingual system and a palatal displacement in apical area and a labial movement in the incisal edge in Labial systemin. In overtorqued upper central incisor, the labial crown displacement in Labial system is more than Lingual system. CONCLUSIONS: In labial and lingual system on application of the same forces in upper central incisor with different inclinations showed different responses. The magnitudes of torque Loss during intrusive loads in incisors with normal, under and over-torque were higher in Labial system than Lingual orthodontic appliances. Key words:FEM, lingual orthodontics, intrusion, torque control, labial bracket systems Medicina Oral S.L. 2018-01-01 /pmc/articles/PMC5899806/ /pubmed/29670711 http://dx.doi.org/10.4317/jced.54461 Text en Copyright: © 2018 Medicina Oral S.L. http://creativecommons.org/licenses/by/2.5/ This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research
Pol, Tejas R.
Vandekar, Meghna
Patil, Anuradha
Desai, Sanjana
Shetty, Vikram
Hazarika, Saptarshi
Torque Control During Intrusion on Upper Central Incisor in Labial and Lingual bracket System - A 3D Finite Element Study
title Torque Control During Intrusion on Upper Central Incisor in Labial and Lingual bracket System - A 3D Finite Element Study
title_full Torque Control During Intrusion on Upper Central Incisor in Labial and Lingual bracket System - A 3D Finite Element Study
title_fullStr Torque Control During Intrusion on Upper Central Incisor in Labial and Lingual bracket System - A 3D Finite Element Study
title_full_unstemmed Torque Control During Intrusion on Upper Central Incisor in Labial and Lingual bracket System - A 3D Finite Element Study
title_short Torque Control During Intrusion on Upper Central Incisor in Labial and Lingual bracket System - A 3D Finite Element Study
title_sort torque control during intrusion on upper central incisor in labial and lingual bracket system - a 3d finite element study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5899806/
https://www.ncbi.nlm.nih.gov/pubmed/29670711
http://dx.doi.org/10.4317/jced.54461
work_keys_str_mv AT poltejasr torquecontrolduringintrusiononuppercentralincisorinlabialandlingualbracketsystema3dfiniteelementstudy
AT vandekarmeghna torquecontrolduringintrusiononuppercentralincisorinlabialandlingualbracketsystema3dfiniteelementstudy
AT patilanuradha torquecontrolduringintrusiononuppercentralincisorinlabialandlingualbracketsystema3dfiniteelementstudy
AT desaisanjana torquecontrolduringintrusiononuppercentralincisorinlabialandlingualbracketsystema3dfiniteelementstudy
AT shettyvikram torquecontrolduringintrusiononuppercentralincisorinlabialandlingualbracketsystema3dfiniteelementstudy
AT hazarikasaptarshi torquecontrolduringintrusiononuppercentralincisorinlabialandlingualbracketsystema3dfiniteelementstudy