Cargando…
Validation and Search of the Ideal Cut-Off of the Sysmex UF-1000i(®) Flow Cytometer for the Diagnosis of Urinary Tract Infection in a Tertiary Hospital in Spain
Urinary tract infections (UTI) are one of the most prevalent infections. A rapid and reliable screening method is useful to screen out negative samples. The objective of this study was to validate the Sysmex flow cytometer UF-1000i by evaluating its accuracy, linearity and carry-over; and define an...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2018
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5900046/ https://www.ncbi.nlm.nih.gov/pubmed/29686988 http://dx.doi.org/10.3389/fmed.2018.00092 |
_version_ | 1783314349808418816 |
---|---|
author | Millán-Lou, María I. García-Lechuz, Juan M. Ruiz-Andrés, María A. López, Concepción Aldea, María J. Revillo, María J. Rezusta, Antonio |
author_facet | Millán-Lou, María I. García-Lechuz, Juan M. Ruiz-Andrés, María A. López, Concepción Aldea, María J. Revillo, María J. Rezusta, Antonio |
author_sort | Millán-Lou, María I. |
collection | PubMed |
description | Urinary tract infections (UTI) are one of the most prevalent infections. A rapid and reliable screening method is useful to screen out negative samples. The objective of this study was to validate the Sysmex flow cytometer UF-1000i by evaluating its accuracy, linearity and carry-over; and define an optimal cut-off value to be used in routine practice in our hospital. For the validation of the UF-1000i cytometer, precision, linearity and carry-over were studied in samples with different counts of bacteria, leukocytes and erythrocytes. Between March and June 2016, urine samples were tested in the Clinical Microbiology Laboratory at University Miguel Servet Hospital, in Spain. Samples were analyzed with the Sysmex UF-1000i cytometer, and cultured. Growth of ≥10(5) CFUs/mL was considered positive. The validation study reveals that the precision in all the variables is acceptable; that there is a good linearity in the dilutions performed, obtaining values almost identical to those theoretically expected; and for the carry-over has practically null values. A total of 1,220 urine specimens were included, of which 213 (17.4%) were culture positive. The optimal cut-off point of the bacteria–leukocyte combination was 138.8 bacteria or 119.8 leukocytes with an S and E of 95.3 and 70.4%, respectively. The UF-1000i cytometer is a valuable method to screen urine samples to effectively rule out UTI and, may contribute to the reduction of unnecessary urine cultures. |
format | Online Article Text |
id | pubmed-5900046 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2018 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-59000462018-04-23 Validation and Search of the Ideal Cut-Off of the Sysmex UF-1000i(®) Flow Cytometer for the Diagnosis of Urinary Tract Infection in a Tertiary Hospital in Spain Millán-Lou, María I. García-Lechuz, Juan M. Ruiz-Andrés, María A. López, Concepción Aldea, María J. Revillo, María J. Rezusta, Antonio Front Med (Lausanne) Medicine Urinary tract infections (UTI) are one of the most prevalent infections. A rapid and reliable screening method is useful to screen out negative samples. The objective of this study was to validate the Sysmex flow cytometer UF-1000i by evaluating its accuracy, linearity and carry-over; and define an optimal cut-off value to be used in routine practice in our hospital. For the validation of the UF-1000i cytometer, precision, linearity and carry-over were studied in samples with different counts of bacteria, leukocytes and erythrocytes. Between March and June 2016, urine samples were tested in the Clinical Microbiology Laboratory at University Miguel Servet Hospital, in Spain. Samples were analyzed with the Sysmex UF-1000i cytometer, and cultured. Growth of ≥10(5) CFUs/mL was considered positive. The validation study reveals that the precision in all the variables is acceptable; that there is a good linearity in the dilutions performed, obtaining values almost identical to those theoretically expected; and for the carry-over has practically null values. A total of 1,220 urine specimens were included, of which 213 (17.4%) were culture positive. The optimal cut-off point of the bacteria–leukocyte combination was 138.8 bacteria or 119.8 leukocytes with an S and E of 95.3 and 70.4%, respectively. The UF-1000i cytometer is a valuable method to screen urine samples to effectively rule out UTI and, may contribute to the reduction of unnecessary urine cultures. Frontiers Media S.A. 2018-04-09 /pmc/articles/PMC5900046/ /pubmed/29686988 http://dx.doi.org/10.3389/fmed.2018.00092 Text en Copyright © 2018 Millán-Lou, García-Lechuz, Ruiz-Andrés, López, Aldea, Revillo and Rezusta. https://creativecommons.org/licenses/by/4.0/ This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Medicine Millán-Lou, María I. García-Lechuz, Juan M. Ruiz-Andrés, María A. López, Concepción Aldea, María J. Revillo, María J. Rezusta, Antonio Validation and Search of the Ideal Cut-Off of the Sysmex UF-1000i(®) Flow Cytometer for the Diagnosis of Urinary Tract Infection in a Tertiary Hospital in Spain |
title | Validation and Search of the Ideal Cut-Off of the Sysmex UF-1000i(®) Flow Cytometer for the Diagnosis of Urinary Tract Infection in a Tertiary Hospital in Spain |
title_full | Validation and Search of the Ideal Cut-Off of the Sysmex UF-1000i(®) Flow Cytometer for the Diagnosis of Urinary Tract Infection in a Tertiary Hospital in Spain |
title_fullStr | Validation and Search of the Ideal Cut-Off of the Sysmex UF-1000i(®) Flow Cytometer for the Diagnosis of Urinary Tract Infection in a Tertiary Hospital in Spain |
title_full_unstemmed | Validation and Search of the Ideal Cut-Off of the Sysmex UF-1000i(®) Flow Cytometer for the Diagnosis of Urinary Tract Infection in a Tertiary Hospital in Spain |
title_short | Validation and Search of the Ideal Cut-Off of the Sysmex UF-1000i(®) Flow Cytometer for the Diagnosis of Urinary Tract Infection in a Tertiary Hospital in Spain |
title_sort | validation and search of the ideal cut-off of the sysmex uf-1000i(®) flow cytometer for the diagnosis of urinary tract infection in a tertiary hospital in spain |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5900046/ https://www.ncbi.nlm.nih.gov/pubmed/29686988 http://dx.doi.org/10.3389/fmed.2018.00092 |
work_keys_str_mv | AT millanloumariai validationandsearchoftheidealcutoffofthesysmexuf1000iflowcytometerforthediagnosisofurinarytractinfectioninatertiaryhospitalinspain AT garcialechuzjuanm validationandsearchoftheidealcutoffofthesysmexuf1000iflowcytometerforthediagnosisofurinarytractinfectioninatertiaryhospitalinspain AT ruizandresmariaa validationandsearchoftheidealcutoffofthesysmexuf1000iflowcytometerforthediagnosisofurinarytractinfectioninatertiaryhospitalinspain AT lopezconcepcion validationandsearchoftheidealcutoffofthesysmexuf1000iflowcytometerforthediagnosisofurinarytractinfectioninatertiaryhospitalinspain AT aldeamariaj validationandsearchoftheidealcutoffofthesysmexuf1000iflowcytometerforthediagnosisofurinarytractinfectioninatertiaryhospitalinspain AT revillomariaj validationandsearchoftheidealcutoffofthesysmexuf1000iflowcytometerforthediagnosisofurinarytractinfectioninatertiaryhospitalinspain AT rezustaantonio validationandsearchoftheidealcutoffofthesysmexuf1000iflowcytometerforthediagnosisofurinarytractinfectioninatertiaryhospitalinspain |