Differences in efficacy of uncovered self-expandable metal stent in relation to placement in the management of malignant distal biliary obstruction

BACKGROUND/AIMS: Metal stent insertion is a common palliative treatment for distal malignant biliary obstruction (MBO) but whether placement across the sphincter of Oddi (SO) causes more complications or shorter survival is in question. The aim of this study was to compare the clinical outcomes of p...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Jin-Xing, Zu, Qing-Quan, Liu, Sheng, Zhou, Chun-Gao, Xia, Jin-Guo, Shi, Hai-Bin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Medknow Publications & Media Pvt Ltd 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5900478/
https://www.ncbi.nlm.nih.gov/pubmed/29637914
http://dx.doi.org/10.4103/sjg.SJG_326_17
_version_ 1783314421845590016
author Zhang, Jin-Xing
Zu, Qing-Quan
Liu, Sheng
Zhou, Chun-Gao
Xia, Jin-Guo
Shi, Hai-Bin
author_facet Zhang, Jin-Xing
Zu, Qing-Quan
Liu, Sheng
Zhou, Chun-Gao
Xia, Jin-Guo
Shi, Hai-Bin
author_sort Zhang, Jin-Xing
collection PubMed
description BACKGROUND/AIMS: Metal stent insertion is a common palliative treatment for distal malignant biliary obstruction (MBO) but whether placement across the sphincter of Oddi (SO) causes more complications or shorter survival is in question. The aim of this study was to compare the clinical outcomes of percutaneous uncovered self-expandable metal stent placement above and across the SO in patients with distal MBO. PATIENTS AND METHODS: We retrospectively studied 59 patients who underwent uncovered metal stent placement for distal MBO between January 2012 and March 2016. Stents were placed above the SO for 22 subjects (group A) and across the SO for 37 subjects (group B). Early cholangitis, stent occlusion, and overall survival time were compared between the two groups. RESULTS: Clinical success was 90.9 and 86.5% for groups A and B, respectively. Early cholangitis occurred in 2 patients (9.1%) in group A and in 6 patients (16.2%) in group B (P = 0.645). Median stent patency and median survival time was 105 and 140 days for group A, 120 and 160 days for group B, respectively. The stent occlusion (31.8% in group A and 21.6% in group B, P = 0.454) and the cumulative stent patency times (P = 0.886) did not differ between the two groups. There was no significant difference in cumulative patient survival between the two groups (P = 0.810). CONCLUSION: Uncovered metal stent placement across the SO did not significantly affect early cholangitis, stent patency, or patient survival.
format Online
Article
Text
id pubmed-5900478
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher Medknow Publications & Media Pvt Ltd
record_format MEDLINE/PubMed
spelling pubmed-59004782018-04-24 Differences in efficacy of uncovered self-expandable metal stent in relation to placement in the management of malignant distal biliary obstruction Zhang, Jin-Xing Zu, Qing-Quan Liu, Sheng Zhou, Chun-Gao Xia, Jin-Guo Shi, Hai-Bin Saudi J Gastroenterol Original Article BACKGROUND/AIMS: Metal stent insertion is a common palliative treatment for distal malignant biliary obstruction (MBO) but whether placement across the sphincter of Oddi (SO) causes more complications or shorter survival is in question. The aim of this study was to compare the clinical outcomes of percutaneous uncovered self-expandable metal stent placement above and across the SO in patients with distal MBO. PATIENTS AND METHODS: We retrospectively studied 59 patients who underwent uncovered metal stent placement for distal MBO between January 2012 and March 2016. Stents were placed above the SO for 22 subjects (group A) and across the SO for 37 subjects (group B). Early cholangitis, stent occlusion, and overall survival time were compared between the two groups. RESULTS: Clinical success was 90.9 and 86.5% for groups A and B, respectively. Early cholangitis occurred in 2 patients (9.1%) in group A and in 6 patients (16.2%) in group B (P = 0.645). Median stent patency and median survival time was 105 and 140 days for group A, 120 and 160 days for group B, respectively. The stent occlusion (31.8% in group A and 21.6% in group B, P = 0.454) and the cumulative stent patency times (P = 0.886) did not differ between the two groups. There was no significant difference in cumulative patient survival between the two groups (P = 0.810). CONCLUSION: Uncovered metal stent placement across the SO did not significantly affect early cholangitis, stent patency, or patient survival. Medknow Publications & Media Pvt Ltd 2018 /pmc/articles/PMC5900478/ /pubmed/29637914 http://dx.doi.org/10.4103/sjg.SJG_326_17 Text en Copyright: © 2018 Saudi Journal of Gastroenterology http://creativecommons.org/licenses/by-nc-sa/4.0 This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Zhang, Jin-Xing
Zu, Qing-Quan
Liu, Sheng
Zhou, Chun-Gao
Xia, Jin-Guo
Shi, Hai-Bin
Differences in efficacy of uncovered self-expandable metal stent in relation to placement in the management of malignant distal biliary obstruction
title Differences in efficacy of uncovered self-expandable metal stent in relation to placement in the management of malignant distal biliary obstruction
title_full Differences in efficacy of uncovered self-expandable metal stent in relation to placement in the management of malignant distal biliary obstruction
title_fullStr Differences in efficacy of uncovered self-expandable metal stent in relation to placement in the management of malignant distal biliary obstruction
title_full_unstemmed Differences in efficacy of uncovered self-expandable metal stent in relation to placement in the management of malignant distal biliary obstruction
title_short Differences in efficacy of uncovered self-expandable metal stent in relation to placement in the management of malignant distal biliary obstruction
title_sort differences in efficacy of uncovered self-expandable metal stent in relation to placement in the management of malignant distal biliary obstruction
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5900478/
https://www.ncbi.nlm.nih.gov/pubmed/29637914
http://dx.doi.org/10.4103/sjg.SJG_326_17
work_keys_str_mv AT zhangjinxing differencesinefficacyofuncoveredselfexpandablemetalstentinrelationtoplacementinthemanagementofmalignantdistalbiliaryobstruction
AT zuqingquan differencesinefficacyofuncoveredselfexpandablemetalstentinrelationtoplacementinthemanagementofmalignantdistalbiliaryobstruction
AT liusheng differencesinefficacyofuncoveredselfexpandablemetalstentinrelationtoplacementinthemanagementofmalignantdistalbiliaryobstruction
AT zhouchungao differencesinefficacyofuncoveredselfexpandablemetalstentinrelationtoplacementinthemanagementofmalignantdistalbiliaryobstruction
AT xiajinguo differencesinefficacyofuncoveredselfexpandablemetalstentinrelationtoplacementinthemanagementofmalignantdistalbiliaryobstruction
AT shihaibin differencesinefficacyofuncoveredselfexpandablemetalstentinrelationtoplacementinthemanagementofmalignantdistalbiliaryobstruction