Cargando…

Thoracic Inlet Parameters for Degenerative Cervical Spondylolisthesis Imaging Measurement

BACKGROUND: The aim of this study was to explore the diagnostic value of sagittal measurement of thoracic inlet parameters for degenerative cervical spondylolisthesis (DCS). MATERIAL/METHODS: We initially included 65 patients with DCS and the same number of health people as the control group by usin...

Descripción completa

Detalles Bibliográficos
Autores principales: Wang, Quanbing, Wang, Xiao-Tao, Zhu, Lei, Wei, Yu-Xi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2018
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5901044/
https://www.ncbi.nlm.nih.gov/pubmed/29621202
http://dx.doi.org/10.12659/MSM.907073
_version_ 1783314532398006272
author Wang, Quanbing
Wang, Xiao-Tao
Zhu, Lei
Wei, Yu-Xi
author_facet Wang, Quanbing
Wang, Xiao-Tao
Zhu, Lei
Wei, Yu-Xi
author_sort Wang, Quanbing
collection PubMed
description BACKGROUND: The aim of this study was to explore the diagnostic value of sagittal measurement of thoracic inlet parameters for degenerative cervical spondylolisthesis (DCS). MATERIAL/METHODS: We initially included 65 patients with DCS and the same number of health people as the control group by using cervical radiograph evaluations. We analyzed the x-ray and computer tomographic (CT) data in prone and standing position at the same time. Measurement of cervical sagittal parameters was carried out in a standardized supine position. Multivariate logistic regression analysis was performed to evaluate these parameters as a diagnostic index for DCS. RESULTS: There were 60 cases enrolled in the DCS group, and 62 cases included in the control group. The T1 slope and thoracic inlet angle (TIA) were significantly greater for the DCS group compared to the control group (24.33±2.85º versus 19.59±2.04º, p=0.00; 76.11±9.82º versus 72.86±7.31º, p=0.03, respectively). We observed no significant difference for the results of the neck tilt (NT), C2–C7 angle in the control and the DSC group (p>0.05). Logistic regression analysis and receiver operating characteristic (ROC) curve revealed that preoperative T1 slope of more than 22.0º showed significantly diagnostic value for the DCS group (p<0.05). CONCLUSIONS: Patients with preoperative sagittal imbalance of thoracic inlet have a statistically significant increased risk of DCS. T1 slope of more than 22.0º showed significantly diagnostic value for the incidence of DCS.
format Online
Article
Text
id pubmed-5901044
institution National Center for Biotechnology Information
language English
publishDate 2018
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-59010442018-04-17 Thoracic Inlet Parameters for Degenerative Cervical Spondylolisthesis Imaging Measurement Wang, Quanbing Wang, Xiao-Tao Zhu, Lei Wei, Yu-Xi Med Sci Monit Clinical Research BACKGROUND: The aim of this study was to explore the diagnostic value of sagittal measurement of thoracic inlet parameters for degenerative cervical spondylolisthesis (DCS). MATERIAL/METHODS: We initially included 65 patients with DCS and the same number of health people as the control group by using cervical radiograph evaluations. We analyzed the x-ray and computer tomographic (CT) data in prone and standing position at the same time. Measurement of cervical sagittal parameters was carried out in a standardized supine position. Multivariate logistic regression analysis was performed to evaluate these parameters as a diagnostic index for DCS. RESULTS: There were 60 cases enrolled in the DCS group, and 62 cases included in the control group. The T1 slope and thoracic inlet angle (TIA) were significantly greater for the DCS group compared to the control group (24.33±2.85º versus 19.59±2.04º, p=0.00; 76.11±9.82º versus 72.86±7.31º, p=0.03, respectively). We observed no significant difference for the results of the neck tilt (NT), C2–C7 angle in the control and the DSC group (p>0.05). Logistic regression analysis and receiver operating characteristic (ROC) curve revealed that preoperative T1 slope of more than 22.0º showed significantly diagnostic value for the DCS group (p<0.05). CONCLUSIONS: Patients with preoperative sagittal imbalance of thoracic inlet have a statistically significant increased risk of DCS. T1 slope of more than 22.0º showed significantly diagnostic value for the incidence of DCS. International Scientific Literature, Inc. 2018-04-05 /pmc/articles/PMC5901044/ /pubmed/29621202 http://dx.doi.org/10.12659/MSM.907073 Text en © Med Sci Monit, 2018 This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
Wang, Quanbing
Wang, Xiao-Tao
Zhu, Lei
Wei, Yu-Xi
Thoracic Inlet Parameters for Degenerative Cervical Spondylolisthesis Imaging Measurement
title Thoracic Inlet Parameters for Degenerative Cervical Spondylolisthesis Imaging Measurement
title_full Thoracic Inlet Parameters for Degenerative Cervical Spondylolisthesis Imaging Measurement
title_fullStr Thoracic Inlet Parameters for Degenerative Cervical Spondylolisthesis Imaging Measurement
title_full_unstemmed Thoracic Inlet Parameters for Degenerative Cervical Spondylolisthesis Imaging Measurement
title_short Thoracic Inlet Parameters for Degenerative Cervical Spondylolisthesis Imaging Measurement
title_sort thoracic inlet parameters for degenerative cervical spondylolisthesis imaging measurement
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC5901044/
https://www.ncbi.nlm.nih.gov/pubmed/29621202
http://dx.doi.org/10.12659/MSM.907073
work_keys_str_mv AT wangquanbing thoracicinletparametersfordegenerativecervicalspondylolisthesisimagingmeasurement
AT wangxiaotao thoracicinletparametersfordegenerativecervicalspondylolisthesisimagingmeasurement
AT zhulei thoracicinletparametersfordegenerativecervicalspondylolisthesisimagingmeasurement
AT weiyuxi thoracicinletparametersfordegenerativecervicalspondylolisthesisimagingmeasurement